Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

IGD Explosion-Proof Gas Alarm Detector
Industrial IoT
Explosion-Proof Gas Alarm Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD
Model: HANS-IGD V1.2 explosion-proof gas detector; diffusion sampling; online continuous monitoring.
Electrical: DC 12–30 V; power consumption ≤3 W; response time ≤15 s for the listed sensor modules.
Environment: Operating temperature -10 to +50°C; operating humidity ≤99% RH, non-condensing; ambient pressure 86–106 kPa.
Explosion protection and enclosure: Flameproof construction; Ex d II CT6; IP65/IP66; G1/2 internal thread; wall-mounted; display version 181 × 136 × 93 mm; weight ≤1.5 kg.
Outputs and wiring variants: 4–20 mA, RS485, or PowerBus two-wire according to the ordered configuration. The manual specifies separate cable and terminal arrangements for each; do not combine them as simultaneous outputs. Maximum detector-to-controller distance ≤1000 m. Cable requirements: shielded cable ≥1.5 mm² × 3 for 4–20 mA, ×4 for RS485, ×2 for PowerBus; cable outer diameter 6–9 mm.
Replaceable gas modules: NH3 0–500 ppm, accuracy ≤±3% of reading, response <15 s, resolution 0.1/1 ppm; SO2 0–2000 ppm, ≤±3%, <15 s, 0.1/1 ppm; combustible gas 0–100% LEL, ≤±5%, <15 s, 1% LEL/1% VOL; H2S 0–1000 ppm, ≤±3%, <15 s, 1 ppm; CO 0–2000 ppm, ≤±3%, <15 s, 1 ppm. The flammable-gas module option list includes methane, acetone, ethanol, ethyl acetate, ethylene, hydrogen, isopropanol, methanol, methyl ethyl ketone, n-butane, n-heptane, n-hexane, n-pentane, propane, n-octane, toluene, styrene, organic solvents, CO, acetic acid and unleaded gasoline. The manual describes different replaceable modules; these are not all installed simultaneously.
Service life: Sensor life approximately 2 years in normal clean ambient conditions.
RS485 protocol: Modbus RTU; 8 data bits, no parity, 1 stop bit, CRC; baud rates 600/1200/4800/9600 bps (default 9600); device address default 0x01, configurable 1–239. Function 0x03 reads registers and 0x10 writes settings. Register map and frame examples are in printed manual pp.12–15.
Alarm and operation: Startup self-check and sensor preheat (typically 120 s, dependent on sensor type); low/high alarm thresholds and relay status are configurable. The manual specifies sensor replacement and recalibration procedures.

IGD-KL
Industrial IoT
Gas / Dust Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD-KL
Model: HANS-IGD-KL V1.3 explosion-proof dust detector. Continuous 24-hour online monitoring of combustible and hazardous dust, with audible/visual alarm and standard signal output for PLC/DCS and alarm systems.
Detection: Laser-scattering principle; PM2.5, PM10 and PM1.0; range 0–1000 μg/m³ (expandable); resolution 1 μg/m³. Accuracy: 0–100 μg/m³ ±10 μg/m³; 101–1000 μg/m³ ±10% of reading. Batch data consistency ≥90%.
Electrical and outputs: DC 10–36 V supply; operating current ≤300 mA; RS485 with Modbus RTU; optional 4–20 mA output; one relay, AC250V 5A, normally open.
Environment: Working humidity 0–99% RH, non-condensing; storage temperature -30 to 60°C; storage humidity 0–99% RH, non-condensing. No operating-temperature range or IP rating is stated in the parameter table.
Communications: Modbus RTU; configurable address 1–255, default 1; default baud rate 9600; 8 data bits, 1 stop bit, no parity. Separate RS485 and 4–20mA wiring configurations are documented.
Identity: IGD-KL is taken from the exact manual cover and retained as the canonical model label; no IGD variant is inferred.

IGD-TH Explosion-Proof Temperature & Humidity Detector
Industrial IoT
Explosion-Proof Temperature & Humidity Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD-TH
Model: HANS-IGD-TH V1.3 explosion-proof temperature and humidity detector. Continuous measurement for indoor/outdoor and industrial environments.
Measurement: Temperature range -40 to +125°C; humidity range 0–100% RH. Accuracy ±0.5°C within 0–90°C; humidity ±3% RH under 25°C and 1m/s airflow. Resolution 0.1°C and 1% RH.
Electrical/environment: DC 12–30V; power ≤3W; response time ≤15s; operating temperature -40 to +85°C; operating humidity 0–90% RH, non-condensing; ambient pressure 86–106kPa.
Explosion protection and enclosure: Flameproof Ex d II CT6; IP65/IP66; G1/2 internal thread; wall-mounted; display version 181 × 136 × 93mm; weight ≤1.5kg.
Outputs/configurations: 4–20mA temperature output (-40 to +100°C) and 4–20mA humidity output (0–100% RH); RS485; or PowerBus two-wire according to ordered configuration. Separate wiring diagrams are provided for analog, RS485 and PowerBus versions. Relay and audible/visual alarm wiring options are also shown. Do not assume every output is installed simultaneously.
Wiring: Analog version: V power positive, G power negative, S1 temperature output, S2 humidity output. RS485 version: V, G, A=RS485A, B=RS485B. PowerBus uses 24V positive/negative with polarity matching the controller. Product label governs wire colors.
Communications: Modbus RTU; 8 data bits, no parity, 1 stop bit, CRC; baud rates 600/1200/4800/9600bps (default 9600); device address default 0x01. Function 0x03 reads registers; function 0x10 writes settings. Temperature registers include integer and float representations; humidity registers use integer representation with three decimal places; address and baud-rate registers are documented.
Display/menu: Four-digit seven-segment LED; normal/fault/high/low status indications. Menus include low/high alarm thresholds, full scale, zero calibration, temperature/humidity calibration, bus address and optional remote-control handshake.
Configuration boundary: Output type and relay/alarm wiring depend on ordered hardware configuration. The manual distinguishes analog, RS485 and PowerBus variants; do not combine them into a single guaranteed interface set.

IR62 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR62
Model: IR62
Specification: HANS-IR62 Infrared Temperature Sensor RS485 Module
Measurement range: Product variants: 0–200/300/400/500/600/800/1200°C; -20–100/200/300/500/600/1200°C. Shared Modbus register envelope -50…600°C is NOT the calibrated range of every product.
Accuracy: ±2% of reading or ±2°C, whichever is greater
Resolution: Optical resolution 15:1 or 20:1, configuration-dependent
Power supply: 6–32VDC overall; variant/output wiring supply may differ
Communication: RS-485 serial output
Output signal: 0–5V, 0–10V, 4–20mA, RS485 or K-type thermocouple (configuration-dependent)
Operating temperature: 0–60°C
Operating humidity: 10–95% RH, non-condensing
IP rating: IP65

IR62S-69 Online Infrared Temperature Sensor
Industrial IoT
Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR62S-69
Model: IR62S-69
Specification: HANS-IR62S-69 Online Infrared Temperature Sensor
Measurement range: Variant-dependent: 0–100°C, 0–200°C, 0–300°C, 0–400°C, 0–500°C; Modbus register envelope −50 to +600°C subject to actual variant limits
Accuracy: ±1% of reading or ±1°C, whichever is greater
Resolution: Optical resolution 15:1
Power supply: 6–28VDC for 4–20mA/RS485; 11–28VDC for 0–5V/0–10V/K-type thermocouple
Output signal: 0–5V, 0–10V, 4–20mA, RS485 or K-type thermocouple (variant-dependent)
Operating temperature: 0 to +60°C
Operating humidity: 10–95% RH, non-condensing

IR65 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR65
Model: HANS-IR65 V1.0 online infrared temperature sensor.
Measurement: Variant ranges 0–100/200/300/400/500/600°C; wavelength 8–14μm; emissivity preset 0.95 and software-adjustable. Field of view 8.5°; DS ratio 20:1 and optical resolution 20:1; maximum detection distance 6m. Response 600ms (95%); accuracy ±2% of reading; repeatability ±0.5% of reading.
Electrical/output: DC12–28V; current consumption 2.9–3.3mA; 4–20mA output. Wiring: red DC positive 12–28V, black 4–20mA signal positive, transparent shield. Cable 1.5m standard; other lengths custom.
Construction/environment: Stainless-steel body; IP65; relative humidity 20–80% non-condensing; storage/ambient technical table gives -20 to +85°C. Dimensions 118mm × Ø18mm.
Ambient-temperature source conflict: The technical table on p.2513 states -20…+85°C, while the ambient-condition note on p.2514 states 0…60°C. Preserve both as conflicting source statements; do not normalize. This record remains on HOLD.
Installation/use: M18×1 threaded housing; direct or bracket installation. Ensure optical path is unobstructed and target fills the field of view; keep lens clean and protect from electromagnetic interference. Cooling protection sleeve may be required outside the stated 0…60°C ambient note.

IR80 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-IR80
Measurement ranges: Selectable variants include 0–100, 0–200, 0–300, 0–500, 0–600, 0–900 and 0–1200°C.
Optical and response: Fixed emissivity 0.95; wavelength 8–14 μm; optical resolution 20:1 or 30:1; response time 300 ms (95%).
Accuracy and repeatability: Accuracy ±2% or ±2°C, whichever is greater; repeatability ±1% or ±1.5°C, whichever is greater.
Electrical and output: Supply 6–32 VDC. Output options include 4–20 mA, 0–5 V, 0–10 V, K-type or RS485, depending on configuration.
RS485 serial settings: 9600 bps, 8 data bits, no parity, 1 stop bit. Read function 0x03; register 0x0004 provides infrared temperature data. Register scaling and usable range must be matched to the selected sensor range.
Mechanical and protection: Stainless-steel body; standard IP65, with selected custom IP68 options. Length variants include 113, 96, 94, 86 or 69 mm × Ø18 mm.
Configuration: Measurement range, optical resolution, output and enclosure options are model-dependent. Confirm the selected configuration and ambient operating limits before ordering.

JSD01
Industrial IoT
Monitoring Station
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
JSD01
Model: JSD01
Specification: JSD01 Flooding Monitoring Station
Measurement range: 80 cm / 160 cm / 240 cm / 320 cm / 400 cm (80 cm sections combinable)
Power supply: AC 220 V mains power
Communication: 4G output; RS-485 (Modbus) device interface
Installation: Wall-mounted

FAC02 Standalone Photoelectric Smoke Alarm
Industrial IoT
Photoelectric Smoke Alarm
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
FAC02 Standalone Photoelectric Smoke Alarm
Standalone photoelectric smoke detection for residential and small commercial spaces. Detects smoke and provides a local audible fire warning.
Power: 9 V battery operation.
Confirm the exact model revision, alarm output, battery type and installation requirements against the applicable HANS product documentation before ordering.

JTY-GD-SF3001D Wired Smoke Alarm
Industrial IoT
Wired Smoke Alarm
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
JTY-GD-SF3001D
Identity: JTY-GD-SF3001D wired photoelectric smoke alarm V1.0, independent manual 组合1 p.2658–2665.
Power: Rated working voltage DC9–15V; the overview separately describes one 9V battery and standby use longer than one year. These statements are retained separately; no unsupported wiring topology is inferred. Standby current ≤15μA; alarm current ≤18mA.
Alarm output: Normally-open dry contact as default; normally-closed or level-signal variants by customization. On smoke alarm the relay output and red indicator activate; built-in buzzer warns on site. Do not assume simultaneously installed output variants.
Construction/environment: −10 to +55°C, RH≤95% non-condensing; ABS housing; 120g; Ø105×56.5mm including base; mounting-hole spacing 62.5–70mm; ceiling installation.
Operation: Photoelectric smoke detection; approx. 60-second normal indicator flash; smoke checked every 10 seconds; self-test with TEST key. Avoid persistent smoke, dust, steam, oil mist, corrosion, high airflow exceeding 5m/s, or humidity beyond specified limit.

L505
Industrial IoT
SF6 & Oxygen Gas Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
L505
Model: L505
Specification: HANS-L505 Wireless SF6 and Oxygen Sensor
Measurement range: SF6 0–2000ppmv standard (customizable); O2 1–25%
Accuracy: SF6 ≤±5%FS (calibrated better than 3%FS); O2 <±1%FS or 0.5% at 18–21%
Power supply: DC 24V
Communication: LoRa wireless
Operating temperature: −30 to +85°C
Operating humidity: ≤95% RH
Installation: Magnetic or wall-mounted

L5301 Intelligent Wireless Acquisition Terminal
Industrial IoT
Data Acquisition Unit
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
L5301
Identity and role (组合1 p.3891–3894): HANS-L5301 V1.4 Intelligent Wireless Data Acquisition Terminal. Collects data from temperature, temperature/humidity, vibration, water-leak, door-contact, smoke, SF6+O2 and partial-discharge sensors.
Technical table (p.3894): Ambient temperature -40 to +85°C; ambient humidity 0–90% RH; working voltage 12–36 VDC; downlink LoRa; uplink RS-232, RS-485 and Ethernet; optional 4G, Wi-Fi and 5G expansion; LoRa line-of-sight range 3000 m; enclosure 100 × 72 × 25 mm; fixed mounting with mounting holes; stated service life >10 years.
Sensor configuration capacity (p.3898): Single-value sensor entries up to 120; dual-value up to 240; three-value up to 60; four-value up to 60. Device offline timeout is configurable in hours, minimum 1 hour, default 24 hours.
Value mapping (p.3901): V1–V4 fields vary by sensor type; three-axis vibration maps X/Y/Z; three-axis vibration plus temperature maps X/Y/Z and temperature.
Communications (p.3902): UART and RS485 use Modbus RTU at 9600 bps, 8 data bits, 1 stop bit, no parity. RJ45 uses Modbus TCP; default IP 192.168.1.111, subnet 255.255.255.0, gateway 192.168.1.1, port 1200 (configurable).
Register map (pp.3902–3904): Includes device serial number, Modbus ID, Ethernet configuration, single-value sensor block at 0x0400, dual-value block at 0x0800 (SF6+O2), three-value block at 0x1000, four-value block at 0x4000, and upload counter at 0x8300. Function 0x03 reads sensor values; 0x04 reads registers/configuration/IDs; 0x10 writes registers.
Power-supply variance: The p.3894 technical table specifies 12–36 VDC. The p.3904 usage notes state DC9–40 V may be used in field conditions, while also specifying a DC12V adapter as standard. Preserve both statements; do not normalize the power field until the manufacturer confirms their relationship.

L5308 Intelligent Acquisition Terminal
Industrial IoT
Data Acquisition Unit
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
L5308
Model: HANS-L5308 V1.0 — Intelligent Wireless Acquisition Terminal.
Processor: industrial 32-bit ARM MCU; FLASH 128 KB; SRAM 16 KB; data-storage FLASH 32 Mb.
Input power: DC 5–28 V; solar power is also listed as a supported supply method. Controlled outputs: DC 5 V; optional controllable DC 12 V/24 V. Output current: 24 V 70 mA; 12 V 200 mA. Standby current: <30 mA.
Uplink: 4G CAT1 full-network (default) or Ethernet. Downlink: RS-485 (default) or RS-232. Configuration: RS-485 and Bluetooth. Interfaces: one RS-485, one RS-232, RJ45 Ethernet; 4G/LoRa external antenna port, Bluetooth antenna and SIM slot.
Temperature: operating −40 to +70°C; storage −45 to +85°C. Acquisition interval: default 5 minutes; selectable 1/5/10/30 minutes or 1 hour. Upload interval: default 1 hour; selectable 1/5/10/30 minutes, 1/2/4/6/12/24 hours. recommended operating practice is upload intervals of 1 hour or longer.
Protection: IP65. Dimensions: 190 × 114.7 × 27 mm. Platform: IoT Smart Platform or customer private platform.
Configuration example: the manual includes Z3TDB-05C wiring (green A, blue B, brown power+, black power−) as a connected sensor example only. These are not L5308 terminal-wire colors and are not generalized to other sensors. The manual also notes VO1 can power only one device; multiple devices require external power.

LDG-W05 Five-in-One Partial Discharge Sensor
Industrial IoT
Partial Discharge Monitoring Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Acoustic emission; transient earth voltage; ultra-high-frequency partial discharge sensing
SPECIFICATIONS
AE: 0–60 dBµV, 37–43 kHz. TEV: 0–60 dBmV, 3–100 MHz. UHF: −45 to +10 dBm, 300–1500 MHz. Noise: 40–120 dB. Temperature measurement: −40 to +125°C, ±1°C; humidity measurement: 0–100% RH, ±3% RH. Default sampling 30 min and reporting 10 min, separately configurable; confirm timing behavior for the intended monitoring strategy. 433 MHz wireless, up to 200 m in open areas. Lithium thionyl chloride battery, nominal three-year life; actual life depends on operation. Outputs include background noise, discharge amplitude, pulse count, warning level and PRPS/PRPD data. Compatible host: HANS-LDG-G20. Sensor body dimensions, ambient operating limits, battery capacity and IP rating not confirmed.
External equipment mounting, wireless pairing and host-side configuration by authorized personnel in accordance with site electrical safety procedures. No unconditional live-work authorization implied.

HANS-LSSW-W10-S18 Radar Flow and Velocity Meter
Industrial IoT
Radar Flow and Velocity Meter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
LSSW-W10-S18
Model: HANS-LSSW-W10-S18 radar level/velocity integrated flow meter V1.0, independent from ultrasonic flowmeter. Non-contact bidirectional measurements and channel cross-section calculation.
Velocity: 0.1–20m/s, ±0.01m/s accuracy, 0.001m/s resolution; speed-sensing distance 0.1–20m. Water-level distance: 0.1–30m, ±2mm, 1mm resolution. Both antennas horizontal beam ±8°, pitch ±10°.
Power/environment: DC9–36V, 12V recommended, average 160mA@12V; work -20…75°C, storage -20…80°C, up to 95%RH non-condensing, IP67; 222×120×92mm excluding bracket. RS485/RS232 ports, integrated 4G and Bluetooth configuration.
Internal auxiliary sensors: temperature -30…80°C with source-stated ±0.01°C; humidity 0–100%RH source-stated 0.024%RH; tilt range −90…90° with source-stated 2% accuracy. These are source claims, not calibration certificates.
Modbus: 9600 baud default, address 1, CRC16; function 03 read and 06 write. Register 0x1008 level, 0x100A velocity, 0x100C flow direction, 0x100D instantaneous flow, 0x100F positive cumulative, 0x1011 reverse cumulative. Register 0x1013 is labelled Doppler velocity but the manual explicitly says this device has no Doppler velocity and returns zero. Channel configuration supports round, rectangular, trapezoid, U and custom geometry.
Wiring: red power+, black power-, blue RS485-A, brown RS485-B, green/purple RS232 upgrade-only TX/RX, yellow BOOT.

MWS01 Piezoelectric Rain Gauge
Industrial IoT
Piezoelectric Rain Gauge
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
MWS01
Model: MWS01
Specification: HANS-MWS01 Piezoelectric Rain Gauge
Measurement range: Piezoelectric rain intensity 0–200 mm/h
Resolution: 0.01 mm rainfall
Power supply: DC12–24V
Communication: RS485 Modbus
Operating temperature: 0 to +70°C
- Page 22