IGD-KL
IGD-KL is listed in the HANS Industrial IoT product catalog as a gas / dust detector under Industrial Sensors. Measurement range: 0–1000 μg/m³ (expandable). Accuracy: 0–100 μg/m³: ±10 μg/m³; 101–1000 μg/m³: ±10% of reading. Power supply: DC 10–36 V. Communication: RS485; optional 4–20 mA. Reference information only; model configuration and availability are subject to confirmation before ordering.


PRODUCT TYPE
Gas / Dust Detector
TECHNOLOGY
TECHNICAL DATA
Model: HANS-IGD-KL V1.3 explosion-proof dust detector. Continuous 24-hour online monitoring of combustible and hazardous dust, with audible/visual alarm and standard signal output for PLC/DCS and alarm systems.
Detection: Laser-scattering principle; PM2.5, PM10 and PM1.0; range 0–1000 μg/m³ (expandable); resolution 1 μg/m³. Accuracy: 0–100 μg/m³ ±10 μg/m³; 101–1000 μg/m³ ±10% of reading. Batch data consistency ≥90%.
Electrical and outputs: DC 10–36 V supply; operating current ≤300 mA; RS485 with Modbus RTU; optional 4–20 mA output; one relay, AC250V 5A, normally open.
Environment: Working humidity 0–99% RH, non-condensing; storage temperature -30 to 60°C; storage humidity 0–99% RH, non-condensing. No operating-temperature range or IP rating is stated in the parameter table.
Communications: Modbus RTU; configurable address 1–255, default 1; default baud rate 9600; 8 data bits, 1 stop bit, no parity. Separate RS485 and 4–20mA wiring configurations are documented.
Identity: IGD-KL is taken from the exact manual cover and retained as the canonical model label; no IGD variant is inferred.
SPECIFICATIONS
IGD-KL
Model: HANS-IGD-KL V1.3 explosion-proof dust detector. Continuous 24-hour online monitoring of combustible and hazardous dust, with audible/visual alarm and standard signal output for PLC/DCS and alarm systems.
Detection: Laser-scattering principle; PM2.5, PM10 and PM1.0; range 0–1000 μg/m³ (expandable); resolution 1 μg/m³. Accuracy: 0–100 μg/m³ ±10 μg/m³; 101–1000 μg/m³ ±10% of reading. Batch data consistency ≥90%.
Electrical and outputs: DC 10–36 V supply; operating current ≤300 mA; RS485 with Modbus RTU; optional 4–20 mA output; one relay, AC250V 5A, normally open.
Environment: Working humidity 0–99% RH, non-condensing; storage temperature -30 to 60°C; storage humidity 0–99% RH, non-condensing. No operating-temperature range or IP rating is stated in the parameter table.
Communications: Modbus RTU; configurable address 1–255, default 1; default baud rate 9600; 8 data bits, 1 stop bit, no parity. Separate RS485 and 4–20mA wiring configurations are documented.
Identity: IGD-KL is taken from the exact manual cover and retained as the canonical model label; no IGD variant is inferred.