JTY-GD-SF3001D Wired Smoke Alarm
JTY-GD-SF3001D is a wired smoke alarm using a photoelectric smoke sensor. The technical documentation specifies DC9–15V operation, normally-open alarm output by default, optional normally-closed or level output, and ceiling installation for attended fire-warning applications.


PRODUCT TYPE
Wired Smoke Alarm
TECHNOLOGY
TECHNICAL DATA
Identity: JTY-GD-SF3001D wired photoelectric smoke alarm V1.0, independent manual 组合1 p.2658–2665.
Power: Rated working voltage DC9–15V; the overview separately describes one 9V battery and standby use longer than one year. These statements are retained separately; no unsupported wiring topology is inferred. Standby current ≤15μA; alarm current ≤18mA.
Alarm output: Normally-open dry contact as default; normally-closed or level-signal variants by customization. On smoke alarm the relay output and red indicator activate; built-in buzzer warns on site. Do not assume simultaneously installed output variants.
Construction/environment: −10 to +55°C, RH≤95% non-condensing; ABS housing; 120g; Ø105×56.5mm including base; mounting-hole spacing 62.5–70mm; ceiling installation.
Operation: Photoelectric smoke detection; approx. 60-second normal indicator flash; smoke checked every 10 seconds; self-test with TEST key. Avoid persistent smoke, dust, steam, oil mist, corrosion, high airflow exceeding 5m/s, or humidity beyond specified limit.
SPECIFICATIONS
JTY-GD-SF3001D
Identity: JTY-GD-SF3001D wired photoelectric smoke alarm V1.0, independent manual 组合1 p.2658–2665.
Power: Rated working voltage DC9–15V; the overview separately describes one 9V battery and standby use longer than one year. These statements are retained separately; no unsupported wiring topology is inferred. Standby current ≤15μA; alarm current ≤18mA.
Alarm output: Normally-open dry contact as default; normally-closed or level-signal variants by customization. On smoke alarm the relay output and red indicator activate; built-in buzzer warns on site. Do not assume simultaneously installed output variants.
Construction/environment: −10 to +55°C, RH≤95% non-condensing; ABS housing; 120g; Ø105×56.5mm including base; mounting-hole spacing 62.5–70mm; ceiling installation.
Operation: Photoelectric smoke detection; approx. 60-second normal indicator flash; smoke checked every 10 seconds; self-test with TEST key. Avoid persistent smoke, dust, steam, oil mist, corrosion, high airflow exceeding 5m/s, or humidity beyond specified limit.
KEY FEATURES
JTY-GD-SF3001D is a wired smoke alarm using a photoelectric smoke sensor. The technical documentation specifies DC9–15V operation, normally-open alarm output by default, optional normally-closed or level output, and ceiling installation for attended fire-warning applications.