Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

DPC01 Wall-Mounted Airborne Particle Counter
Industrial IoT
Airborne Particle Counter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Model-specific technical data status: The supplied DPC01 product page identifies a wall-mounted airborne particle counter for cleanrooms and laboratories and lists 21 product images and one download. The linked file is titled “粒子计数传感器风扇版DPC01-FS.docx” (DPC01-FS fan version), not a DPC01-specific manual. Its numerical specifications have therefore not been assigned to DPC01.
Identity separation: DPC01 is maintained separately from DPC01-FS, DPC01-2.83L and DPC01-FS-H. Sampling flow, particle-size channels, counting range, power, dimensions, communication interfaces and performance values remain unpopulated until a DPC01-specific source is obtained and verified.
Source: https://www.123iot.cn/ProductDetail/7344400.html. Linked download: https://www.123iot.cn/DownLoad/107338.html?urlStatus=1&a=download. The product page lists 21 images; original image binaries, resolution, checksum and model-to-image matching have not yet been authenticated. No image has been written to CMS.

IGDV2-PM Explosion-Proof Industrial Dust Detector
Industrial IoT
Explosion-Proof Industrial Dust Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Laser scattering
SPECIFICATIONS
Technical Specifications — HANS IGDV2-PM
| Manufacturer model | SD123-IGDV2-PM |
|---|---|
| HANS catalog model | IGDV2-PM |
| Device type | Explosion-proof industrial particulate / dust detector |
| Detection principle | Laser scattering |
| Measured parameters | PM2.5, PM10, TSP |
| PM2.5 measurement range | 0–20 mg/m³ |
| PM10 measurement range | 0–60 mg/m³ |
| TSP measurement range | 0–1000 mg/m³ |
| Concentration resolution | 0–10 mg/m³: 0.01 mg/m³; 0–100 mg/m³: 0.1 mg/m³; 0–1000 mg/m³: 1 mg/m³ |
| Response time | ≤15 s |
| Explosion protection type | Flameproof / Ex d; manufacturer-stated marking: Ex dII CT6 (retain as printed; verify exact certificate marking before hazardous-area deployment) |
| Ingress protection | IP65/IP66 (manufacturer page lists both ratings; exact enclosure variant/rating requires confirmation) |
| Supply voltage | DC 6–28 V |
| Power consumption | ≤3 W |
| Digital output | RS485, Modbus-RTU |
| Analog output | Dual-channel 4–20 mA (per supplied product page) |
| Alarm output | Relay output; audible/visual alarm interface |
| Modbus functions | 03 (read registers), 06 (write single register) |
| Baud rate | 1200–115200 bps; default 9600 bps |
| Maximum transmission distance | ≤1000 m (manufacturer-stated) |
| Operating temperature | −20 °C to +85 °C |
| Operating humidity | 0–90% RH, non-condensing |
| Ambient pressure | 86–106 kPa |
| Installation | Wall-mounted |
| Explosion-proof cable entry | M20 × 1.5 internal thread |
| 4–20 mA cable recommendation | Shielded cable ≥1.5 mm² × 3; cable outer diameter 6–9 mm |
| RS485 cable recommendation | Shielded cable ≥1.5 mm² × 4; cable outer diameter 6–9 mm |
| Dimensions | 230 × 178 × 90 mm |
| Weight | ≤2 kg |
| Local display | Digital tube display; cyclic PM2.5 / PM10 / TSP readings |
| Status indicators | Green: normal; red: alarm; yellow: fault |
| Alarm configuration | Independent high/low thresholds and interval alarm settings for PM2.5, PM10 and TSP; offset correction configurable |
Wiring: V/G = DC positive/negative; A1/B1 = RS485 A/B; two 4–20 mA analog channels; relay alarm contacts; external audible/visual alarm interface. Follow the terminal markings on the actual unit and the manufacturer's explosion-proof installation instructions. Unused flameproof cable entries must retain approved stopping plugs and seals.
Certification note: The product page states Ex dII CT6 and cites GB 3836.1-2010 / GB 3836.2-2010, but the certificate number, certificate validity, exact gas/dust group and temperature-class marking have not been independently verified from a certificate document. The page also lists IP65/IP66; do not select one rating without confirming the supplied enclosure.
Source: Manufacturer product page https://www.123iot.cn/ProductDetail/12346840.html; linked manual: https://www.123iot.cn/DownLoad/280775.html?urlStatus=1&a=download. Listed PM ranges, dual analog output and alarm functions are retained as manufacturer-stated data.

SW01-4G Wireless Point Water Leak Sensor
Industrial IoT
4G Wireless Point Water Leak Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications — HANS SW01-4G
| Model | SW01-4G (manufacturer source model: SD123-SW01-4G) |
|---|---|
| Product type | 4G wireless non-positioning point-type water-leak sensor |
| Detection principle | Conductive liquid detection using point probe / leak-detection rope |
| Communication | 4G cellular wireless |
| Power supply | DC 3.7 V |
| Battery type and capacity | Lithium thionyl chloride battery, 19 Ah |
| Manufacturer-stated battery life | 3 years |
| Sleep current | Less than 20 μA |
| Maximum current | Less than 200 mA |
| Reported data | Water-leak alarm status, battery level and signal strength |
| Configuration | Factory default |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | −20 °C to +60 °C |
| Operating humidity | 0–95% RH, non-condensing |
| Storage humidity | 0–95% RH |
| Pressure condition | Standard atmospheric pressure (100 kPa) ±10% |
| Detected liquids | Tap water and groundwater |
| Ingress protection | IP65 |
| Installation | Wall-mounted enclosure; probe secured by screws or double-sided adhesive |
| Probe extension cable | Fixed 0.5 m cable; customized leak-rope length may be selected for the installation |
Source: Manufacturer manual SD123-SW01-4G V1.0, dated 2025-10-30, pp. 1–10. The manual does not specify the 4G bands, protocol, SIM type, alarm contact type, or exact configurable leak-rope length; these are not inferred.

SW01-R4 RS485 Point Water Leak Sensor
Industrial IoT
RS485 Point Water Leak Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications — HANS SW01-R4
| Model | SW01-R4 (manufacturer source model: SD123-SW01-R4) |
|---|---|
| Product type | RS485 point-type water-leak alarm sensor |
| Detection principle | Conductive liquid detection using point probe / leak-detection rope |
| Communication interface | RS485 |
| Communication protocol | Modbus-RTU |
| Digital contact output | Normally-open (NO) contact |
| Power supply | 12–24 V DC, external supply |
| Baud rate | 1,200 / 2,400 / 4,800 / 9,600 / 57,600 / 115,200 bit/s; configurable; factory default 9,600 bit/s |
| Device address | 1–252, configurable; factory default 1 |
| Data format | 8 data bits, no parity, 1 stop bit (8N1) |
| Error checking | 16-bit CRC |
| Function code | Modbus function code 0x03 for register reading |
| Ingress protection | IP65 |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | −20 °C to +60 °C |
| Operating humidity | 0–95% RH |
| Storage humidity | 0–95% RH |
| Pressure condition | Standard atmospheric pressure (100 kPa) ±10% |
| Detected liquids | Tap water and groundwater |
| Installation | Wall-mounted enclosure; leak-detection rope may be positioned vertically or laid along multiple monitoring points / wall edges |
Wiring: Red = DC positive; black = DC negative; yellow = RS485 A; white = RS485 B.
Important installation note: Do not place the sensor enclosure where it can be submerged. Avoid highly corrosive atmospheres (including H₂S, SOx, Cl₂ and HCl) and strong magnetic fields. Protect the unit from impact and vibration.
Source: Manufacturer manual SD123-SW01-R4 V1.1, revised 2025-09-25, and official product page 7569339. The source page and manual specify an NO contact; no relay rating, probe cable length or alarm delay is inferred.

L503 Wireless Magnetic Door Contact Sensor
Industrial IoT
Wireless Magnetic Door Contact Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications — HANS L503
| Model | L503 (manufacturer source model: SD123-L503) |
|---|---|
| Device type | Smart wireless magnetic door contact sensor |
| Detection structure | Wireless transmitter and permanent magnet |
| Supply voltage | 3.6 V DC |
| Operating temperature | −40 °C to +85 °C |
| Operating humidity | 0–80% RH |
| Magnet-to-sensor operating distance | 20–35 mm |
| Mechanical service life | 100,000 operations |
| Wireless transmission options | 433 MHz, 2.4 GHz or LoRa; confirm exact radio variant and order code |
| Wireless state logic | Output 0 = open; output 1 = closed |
| Switch output | Normally open (NO) or normally closed (NC) |
| Installation | Adhesive mounting or screw fixing |
| Applications | Switchgear cabinets, distribution boxes, doors, windows, drawers and safes |
Installation notes: Align transmitter and magnet correctly; confirm the wireless ID with the host controller; minimize radio path distance and avoid steel-reinforced concrete barriers and electrical interference sources; install in a dry location protected from rain and moisture.
Not specified: radio transmit power, communication range, battery capacity/type, current consumption, enclosure rating, antenna type and detailed protocol. These fields are not inferred.

N503 NB-IoT Wireless Magnetic Door Contact Sensor
Industrial IoT
NB-IoT Wireless Magnetic Door Contact Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications — HANS N503
| Model | N503 (manufacturer source model: SD123-N503) |
|---|---|
| Device type | NB-IoT wireless magnetic door contact sensor |
| Detection method | Magnetic contact; wireless transmitter and permanent magnet |
| Monitoring status | Door/window/drawer open and closed state; unauthorized opening or movement event |
| Power supply | DC 3.7 V, 900 mAh rechargeable lithium battery |
| Charging voltage | DC 5 V |
| Wireless communication | NB-IoT |
| Cellular frequency bands | 850 / 900 / 1800 / 2100 MHz |
| Data rate | Uplink: 16 kb/s; downlink: 25 kb/s |
| Sleep current | Less than 15 μA |
| Battery standby life | 6 months, with no more than 10 signal transmissions per day (manufacturer-stated condition) |
| Heartbeat interval | 1 report per day |
| Low-battery alarm voltage | DC 2.7 V |
| Alarm current | Less than 200 mA |
| Operating temperature | −10 °C to +55 °C |
| Relative humidity | Up to 95% RH, non-condensing |
| Communication protocols | China Telecom CoAP; TCP/IP; protocol customization supported |
| Maximum magnetic separation gap | ≤15 mm |
Battery-life qualification: The stated six-month standby life is based on no more than ten signal transmissions per day. Actual service life depends on network coverage, event frequency, reporting configuration, temperature and battery condition.
Source note: Values are transcribed from the user-provided SD123-N503 technical specification. The archived manufacturer product record contains one product image. Product dimensions, ingress protection rating, charging connector, alarm sounder and exact radio-band deployment by carrier were not specified and have not been inferred.

N506 NB-IoT Wireless Water Leak & Water-Level Sensor
Industrial IoT
NB-IoT Water Leak & Water-Level Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications — HANS N506
| Model | N506 (manufacturer source model: SD123-N506) |
|---|---|
| Detection principle | Conductive-water sensing |
| Detection purpose | Water ingress / leakage detection and water-level warning |
| Power supply | DC 3 V, 2400 mAh |
| Wireless communication | NB-IoT; China Telecom, China Mobile and China Unicom |
| Cellular frequency bands | 850 / 900 / 1800 / 2100 MHz |
| Data rate | Uplink: 16 kb/s; downlink: 25 kb/s |
| Sleep current | Less than 10 μA |
| Battery standby life | Up to 3 years, with no more than 5 signal transmissions per day (manufacturer-stated condition) |
| Heartbeat interval | 1 report per day |
| Low-battery alarm voltage | DC 2.7 V |
| Alarm current | Less than 200 mA |
| Operating temperature | −10 °C to +55 °C |
| Relative humidity | Up to 95% RH, non-condensing |
| Communication protocols | China Telecom CoAP; TCP/IP; protocol customization supported |
| Dimensions | 60 × 99 × 27 mm |
| Probe material | Corrosion-resistant material; exact material grade not specified in the supplied source |
| Installation | Adhesive mounting, strapping or fixed mounting, selected for the site |
Battery-life qualification: The stated 3-year standby life is based on no more than five signal transmissions per day. Actual service life depends on network coverage, alarm frequency, environmental conditions and battery characteristics.
Source note: Technical values are transcribed from the user-provided SD123-N506 product specification. The source page currently lists one product image and no downloadable manual in the archived index. No IP rating, exact probe dimensions, measurement range, alarm output type or platform API details have been inferred.

D10-NB NB-IoT Wireless Door & Window Magnetic Contact Sensor
Industrial IoT
Wireless Door / Window Magnetic Contact Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Technical Specifications
| Model | D10-NB (source model: SD123-D10-NB) |
|---|---|
| Sensing principle | Magnet and reed switch |
| Detection | Door / window open and closed state |
| State values | Open = 1; Closed = 0 |
| Wireless communication | NB-IoT, multi-band capable |
| Supported bands | B1 / B2 / B3 / B5 / B8 / B20; default shipment support: B5 |
| Protocol | CoAP |
| Maximum transmit power | 23 dBm |
| Maximum receive sensitivity | −118 dBm |
| Power supply | 2 × AAA batteries; DC 3 V |
| Sleep current | Less than 10 μA |
| Alarm upload current | 230 mA |
| Magnetic trigger distance | 20 mm; recommended installation gap ≤15 mm |
| Operating temperature | 0 °C to +50 °C standard; −10 °C to +55 °C with low-temperature battery option |
| Storage temperature | −40 °C to +85 °C |
| Battery service life | 2 years with E92 batteries or 3 years with L92 batteries, based on 3 reports per day |
| Reporting | Immediate event report when door state changes; scheduled report every 24 hours when unchanged |
| Platform integration | 123 IoT cloud platform by default; Telecom AEP; China Mobile OneNET; custom customer platform integration |
| Alarm notification | SMS, voice call, WeChat, email and platform push notifications, configured through the platform |
| Local indicators | Blue LED flashes on state change; red LED flashes for low battery |
| Manual report | Button near the indicator triggers an upload of the current device state |
Platform data: open_state (1 = open, 0 = closed); arming_state (default 1); battery_voltage (0–3.5 V); battery_value (0–100%); signal-strength and cellular network diagnostic fields.
Source: Manufacturer user manual V1.2, SD123-D10-NB, dated 2022-06-03. Battery life depends on the stated battery type and reporting frequency; actual service life varies with network and field conditions.

HANS-SP11 Smart Differential Pressure Transmitter
Industrial IoT
Differential Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-SP11 Smart Differential Pressure Transmitter
Measurement range: 100 Pa–3 MPa, customizable. Accuracy grades offered: 0.075%, 0.1%, 0.2% and 0.5%.
Stability and drift: manufacturer-stated long-term stability ≤0.02% FS/year and temperature drift ≤0.02% FS/°C. Verify these values against the selected range and order-specific datasheet.
Electrical: 12–24 V DC. Selectable output versions: 4–20 mA; 4–20 mA + RS485 Modbus; or 4–20 mA + HART. These are alternative configurations, not simultaneous standard outputs.
Process: media listed as liquids, gases and steam; process-media temperature −40 to +105°C. Ambient temperature −20 to +70°C. IP65. Manufacturer-stated static-pressure design 16 MPa.
Connections: NPT 1/4 standard; NPT 1/2 and M20 × 1.5 customizable. Optional two-valve and three-valve manifolds.
Display and adjustment: backlit LCD; range, zero and damping adjustment.
Hazardous areas: product page describes an explosion-proof housing structure, but no certificate number, protection marking, issuing authority or standard was supplied. Do not treat this description as verified hazardous-area certification.

HANS-PSM05 AI Smart Pest Monitoring Station
Industrial IoT
AI Insect Monitoring Station
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Dual-spectrum UV attraction; infrared thermal treatment; AI image recognition
SPECIFICATIONS
Dual-spectrum 365/395 nm, 5 W attraction lamp; infrared thermal treatment with manufacturer-claimed mortality ≥98% (test conditions not supplied). Reinforced tempered-glass impact screens at 120°; rainwater separation and automatic drainage; configurable insect cleaning; 5-megapixel camera with automatic imaging and supplemental lighting. 4G upload; GPS positioning; GIS map; automatic light-controlled operation and remote control. 220 VAC mains or optional solar supply. Cloud functions include AI-assisted species recognition, counting, trend reports, PDF/PNG export, pest threshold, offline and fault alerts. Total power, solar panel rating, battery capacity, dimensions, weight, IP rating, operating environment and recognition accuracy are not confirmed.
Cloud analytics also support AI image segmentation and historical pest-data traceability. Exact-model secondary listing corroborates existing specifications; recognition accuracy and supported species count remain unconfirmed.

HANS-SP02V2 NB-IoT Wireless Pressure Transmitter
Industrial IoT
Wireless Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
NB-IoT wireless communication. Default range 0–1.6 MPa; selectable ranges up to 60 MPa. Accuracy ±0.5% FS standard, ±0.2% FS optional. 3.6 V 8.5 Ah lithium thionyl chloride battery; estimated life over five years at 5-minute sampling and 60-minute reporting. Sleep current below 12 µA. Sampling intervals 1/5/10/15/30/60 min; reporting intervals 5/10/15/30/60/120/240/360/720/1440 min. Local LCD and buttons; remote cloud configuration. Reports pressure, battery level, signal strength, alarm thresholds and sampling time. IP67; operating −20 to +70°C. Vertical or horizontal installation; M20 × 1.5 standard thread, customizable. Water, oil and gases compatible with 316 stainless steel; overload twice the selected range.
Confirm required range, network compatibility, media and hazardous-area certification before ordering. No specific explosion-protection certification verified.

HANS-SP03 Wireless Pressure & Level Monitoring Transmitter
Industrial IoT
Wireless Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
External pressure or level sensor; standard input 0.25–2.25 VDC. Default pressure range 0–1 MPa, level range 0–5 m; customizable. Accuracy ±1%; G 1/2 pressure connection, customizable. Supply 3.0–3.6 VDC; ER34615 19 Ah lithium battery; estimated five years at five reports daily; maximum operating current <300 mA. Default sampling 5 min. Internal configuration serial port 9600 bps, 8N1. Built-in FPC antenna. IP65 PC enclosure, 164 × 150 × 71 mm; operating −20 to +70°C, storage −40 to +85°C.
Configurable sampling, periodic reporting, alarm reporting, high/low thresholds and pressure-change alarm. LoRaWAN Class A: 433/470/868/915/923 MHz selectable by region. NB-IoT: B1/B3/B5/B8/B20. Select one communication configuration and compatible external probe; confirm regional network compatibility.

HANS-SP01 Pressure Transmitter
Industrial IoT
Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Diffused silicon
SPECIFICATIONS
24 VDC; selectable pressure ranges from −0.1 MPa up to 60 MPa; overload 200% FS; accuracy ±0.2% or ±0.5% FS; operating −20 to +85°C; storage −40 to +125°C; temperature drift ≤0.02% FS/°C at 0–70°C; IP68; stainless steel housing, PU cable; selectable 201/304/316 stainless steel probe; M20 × 1.5 customizable thread. Output variants: RS485 Modbus RTU half-duplex, 4–20 mA or 0–10 V per technical table. The narrative also mentions 0–5 V; confirm voltage variant before ordering.

HANS-SL02 Wireless Submersible Level Monitoring System
Industrial IoT
Wireless Level Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Hydrostatic pressure sensing
SPECIFICATIONS
0–5 m, customizable; ±0.5% FS; internal FPC antenna; DC 12/24 V or ER26500M 3.6 V non-rechargeable battery; sleep current below 35 μA on battery; IP65 terminal rating; ABS housing; operating −20 to +70 °C; storage −40 to +85 °C. Estimated battery life at least two years under manual section 7.3 conditions: three-minute sampling, up to five messages per day, good coverage at 25 °C. Keep terminal above water; use a protective sleeve and avoid sediment blockage. Verify coverage and media compatibility before installation.
NB-IoT: B1/B3/B5/B8/B20; UDP, CoAP or TCP; peak current below 70 mA at DC12V. LoRaWAN: EU434, CN470, EU868, US915; OTAA or ABP; peak current below 65 mA at DC12V. Other regional bands require confirmation.
Source: SL02 V1.0 manual, pp. 4–6, 9–13; https://www.sd123iot.com/DownLoad/51144.html?a=download.

Electric Vehicle Switched Reluctance Motor Drive System
Motors & Drive Systems
Electric Vehicle Switched Reluctance Motor Drive System
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Switched reluctance motor; programmable electronic drive; regenerative braking
SPECIFICATIONS
Drive type: Switched-reluctance motor drive system
Operating modes: Motor and generator operation; bidirectional energy flow
Control: Programmable control for vehicle operating characteristics
Documented functions: Stepless speed regulation, electromagnetic braking and regenerative energy feedback
Model/rating note: The official listing names a 10 kW EV switched-reluctance motor and a pure-electric bus motor, but does not publish complete model codes or full ratings on the cited detail page. Request vehicle voltage, rated/peak power, speed, torque and cooling details for the required configuration.

Electric Vehicle Charging Pile
Industrial IoT
Electric Vehicle Charging Pile
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
DSP + MCU charging control; touchscreen HMI
SPECIFICATIONS
Enclosure: Stainless steel
Protection rating: Source states P32 for indoor and IP54 for outdoor; the indoor 'P32' notation is retained exactly pending manufacturer confirmation whether this means IP32.
Controller: DSP + MCU microprocessor
Charging modes: Preset energy quantity, timed charging and automatic charging until full
HMI: Touchscreen with charging mode, elapsed/remaining time, delivered/remaining energy and billing information
Protection: Output-side leakage and overcurrent protection
Not specified in cited source: Rated power, AC/DC output, voltage/current, connector standard, communication protocol and payment interface.

Three-Phase Asynchronous Motor High-Efficiency Energy-Saving Controller
Motors & Drive Systems
Three-Phase Asynchronous Motor Energy-Saving Controller
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Solid-state soft start; microprocessor-based load tracking; dynamic voltage/current adjustment
SPECIFICATIONS
Rated output power: 5.5–260 kW
Working voltage: Three-phase 380 V ±10%
Working frequency: 50 Hz ±5%
Overload capability: 4× rated current for 20 s; 3× for 60 s; 1× continuous
Own power consumption: <5 W
Starting frequency: Up to 4 starts/hour at maximum load; up to 60 starts/hour depending on load
Cooling: Natural cooling across series
Ambient temperature: −30 to +65°C
Humidity: Below 95%, non-condensing
Bypass: Manual bypass switch
Enclosure protection: Standard IP30; other protection levels available

Oilfield Pumping Unit High-Efficiency Energy-Saving Controller
Motors & Drive Systems
Oilfield Pumping Unit High-Efficiency Energy-Saving Controller
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Well-specific control program; energy metering; current monitoring; intelligent operating modes
SPECIFICATIONS
Compatible motor types: Y-series motors, high-slip motors and permanent-magnet motors
Voltage: 380 V / 440 V / 660 V
Power range: 11–55 kW
Energy monitoring: Pumping-well energy metering, operating-current detection and accumulated production-time recording
Control: Intelligent operation and conversion between well-testing and production/drainage modes; one-to-one program design according to each well's operating conditions
Cooling: Independent forced-air cooling for low-speed motor operation
Retrofit: Existing motor can remain in place; install the controller without replacing the motor
- Page 3