IGDV2-PM Explosion-Proof Industrial Dust Detector
HANS IGDV2-PM is a wall-mounted flameproof industrial dust detector using laser-scattering measurement to monitor PM2.5, PM10 and total suspended particulates (TSP). It provides RS485 Modbus-RTU digital communication, dual-channel 4–20 mA analog outputs, relay alarm output and an external audible/visual alarm interface. The instrument includes a local digital display, keypad configuration and remote register access for alarm thresholds, device communication settings and measurement offset. The manufacturer states an Ex dII CT6 explosion-protection marking, DC 6–28 V supply, power consumption no greater than 3 W and a maximum transmission distance of 1000 m. It is intended for industrial dust monitoring in mining, building materials, chemical processing, grain handling, grinding and dust-collection systems. Verify the exact explosion-protection certificate and enclosure IP rating for the supplied variant before installation in a classified hazardous area.


PRODUCT TYPE
Explosion-Proof Industrial Dust Detector
TECHNOLOGY
Laser scattering
TECHNICAL DATA
Technical Specifications — HANS IGDV2-PM
| Manufacturer model | SD123-IGDV2-PM |
|---|---|
| HANS catalog model | IGDV2-PM |
| Device type | Explosion-proof industrial particulate / dust detector |
| Detection principle | Laser scattering |
| Measured parameters | PM2.5, PM10, TSP |
| PM2.5 measurement range | 0–20 mg/m³ |
| PM10 measurement range | 0–60 mg/m³ |
| TSP measurement range | 0–1000 mg/m³ |
| Concentration resolution | 0–10 mg/m³: 0.01 mg/m³; 0–100 mg/m³: 0.1 mg/m³; 0–1000 mg/m³: 1 mg/m³ |
| Response time | ≤15 s |
| Explosion protection type | Flameproof / Ex d; manufacturer-stated marking: Ex dII CT6 (retain as printed; verify exact certificate marking before hazardous-area deployment) |
| Ingress protection | IP65/IP66 (manufacturer page lists both ratings; exact enclosure variant/rating requires confirmation) |
| Supply voltage | DC 6–28 V |
| Power consumption | ≤3 W |
| Digital output | RS485, Modbus-RTU |
| Analog output | Dual-channel 4–20 mA (per supplied product page) |
| Alarm output | Relay output; audible/visual alarm interface |
| Modbus functions | 03 (read registers), 06 (write single register) |
| Baud rate | 1200–115200 bps; default 9600 bps |
| Maximum transmission distance | ≤1000 m (manufacturer-stated) |
| Operating temperature | −20 °C to +85 °C |
| Operating humidity | 0–90% RH, non-condensing |
| Ambient pressure | 86–106 kPa |
| Installation | Wall-mounted |
| Explosion-proof cable entry | M20 × 1.5 internal thread |
| 4–20 mA cable recommendation | Shielded cable ≥1.5 mm² × 3; cable outer diameter 6–9 mm |
| RS485 cable recommendation | Shielded cable ≥1.5 mm² × 4; cable outer diameter 6–9 mm |
| Dimensions | 230 × 178 × 90 mm |
| Weight | ≤2 kg |
| Local display | Digital tube display; cyclic PM2.5 / PM10 / TSP readings |
| Status indicators | Green: normal; red: alarm; yellow: fault |
| Alarm configuration | Independent high/low thresholds and interval alarm settings for PM2.5, PM10 and TSP; offset correction configurable |
Wiring: V/G = DC positive/negative; A1/B1 = RS485 A/B; two 4–20 mA analog channels; relay alarm contacts; external audible/visual alarm interface. Follow the terminal markings on the actual unit and the manufacturer's explosion-proof installation instructions. Unused flameproof cable entries must retain approved stopping plugs and seals.
Certification note: The product page states Ex dII CT6 and cites GB 3836.1-2010 / GB 3836.2-2010, but the certificate number, certificate validity, exact gas/dust group and temperature-class marking have not been independently verified from a certificate document. The page also lists IP65/IP66; do not select one rating without confirming the supplied enclosure.
Source: Manufacturer product page https://www.123iot.cn/ProductDetail/12346840.html; linked manual: https://www.123iot.cn/DownLoad/280775.html?urlStatus=1&a=download. Listed PM ranges, dual analog output and alarm functions are retained as manufacturer-stated data.
SPECIFICATIONS
Technical Specifications — HANS IGDV2-PM
| Manufacturer model | SD123-IGDV2-PM |
|---|---|
| HANS catalog model | IGDV2-PM |
| Device type | Explosion-proof industrial particulate / dust detector |
| Detection principle | Laser scattering |
| Measured parameters | PM2.5, PM10, TSP |
| PM2.5 measurement range | 0–20 mg/m³ |
| PM10 measurement range | 0–60 mg/m³ |
| TSP measurement range | 0–1000 mg/m³ |
| Concentration resolution | 0–10 mg/m³: 0.01 mg/m³; 0–100 mg/m³: 0.1 mg/m³; 0–1000 mg/m³: 1 mg/m³ |
| Response time | ≤15 s |
| Explosion protection type | Flameproof / Ex d; manufacturer-stated marking: Ex dII CT6 (retain as printed; verify exact certificate marking before hazardous-area deployment) |
| Ingress protection | IP65/IP66 (manufacturer page lists both ratings; exact enclosure variant/rating requires confirmation) |
| Supply voltage | DC 6–28 V |
| Power consumption | ≤3 W |
| Digital output | RS485, Modbus-RTU |
| Analog output | Dual-channel 4–20 mA (per supplied product page) |
| Alarm output | Relay output; audible/visual alarm interface |
| Modbus functions | 03 (read registers), 06 (write single register) |
| Baud rate | 1200–115200 bps; default 9600 bps |
| Maximum transmission distance | ≤1000 m (manufacturer-stated) |
| Operating temperature | −20 °C to +85 °C |
| Operating humidity | 0–90% RH, non-condensing |
| Ambient pressure | 86–106 kPa |
| Installation | Wall-mounted |
| Explosion-proof cable entry | M20 × 1.5 internal thread |
| 4–20 mA cable recommendation | Shielded cable ≥1.5 mm² × 3; cable outer diameter 6–9 mm |
| RS485 cable recommendation | Shielded cable ≥1.5 mm² × 4; cable outer diameter 6–9 mm |
| Dimensions | 230 × 178 × 90 mm |
| Weight | ≤2 kg |
| Local display | Digital tube display; cyclic PM2.5 / PM10 / TSP readings |
| Status indicators | Green: normal; red: alarm; yellow: fault |
| Alarm configuration | Independent high/low thresholds and interval alarm settings for PM2.5, PM10 and TSP; offset correction configurable |
Wiring: V/G = DC positive/negative; A1/B1 = RS485 A/B; two 4–20 mA analog channels; relay alarm contacts; external audible/visual alarm interface. Follow the terminal markings on the actual unit and the manufacturer's explosion-proof installation instructions. Unused flameproof cable entries must retain approved stopping plugs and seals.
Certification note: The product page states Ex dII CT6 and cites GB 3836.1-2010 / GB 3836.2-2010, but the certificate number, certificate validity, exact gas/dust group and temperature-class marking have not been independently verified from a certificate document. The page also lists IP65/IP66; do not select one rating without confirming the supplied enclosure.
Source: Manufacturer product page https://www.123iot.cn/ProductDetail/12346840.html; linked manual: https://www.123iot.cn/DownLoad/280775.html?urlStatus=1&a=download. Listed PM ranges, dual analog output and alarm functions are retained as manufacturer-stated data.
KEY FEATURES
- Laser-scattering measurement of PM2.5, PM10 and TSP.
- Manufacturer-stated flameproof marking Ex dII CT6.
- RS485 Modbus-RTU and dual-channel 4–20 mA outputs.
- Relay alarm output and external audible/visual alarm interface.
- Local digital display and keypad parameter configuration.
- Remote reading and configuration using Modbus functions 03 and 06.
- Configurable high/low and interval alarm thresholds.
- DC 6–28 V supply; power consumption ≤3 W.
- Wall-mounted enclosure with M20 × 1.5 cable-entry thread.
PRODUCT SYSTEM