Request a Quote

IGDV2-PM Explosion-Proof Industrial Dust Detector

HANS IGDV2-PM is a wall-mounted flameproof industrial dust detector using laser-scattering measurement to monitor PM2.5, PM10 and total suspended particulates (TSP). It provides RS485 Modbus-RTU digital communication, dual-channel 4–20 mA analog outputs, relay alarm output and an external audible/visual alarm interface. The instrument includes a local digital display, keypad configuration and remote register access for alarm thresholds, device communication settings and measurement offset. The manufacturer states an Ex dII CT6 explosion-protection marking, DC 6–28 V supply, power consumption no greater than 3 W and a maximum transmission distance of 1000 m. It is intended for industrial dust monitoring in mining, building materials, chemical processing, grain handling, grinding and dust-collection systems. Verify the exact explosion-protection certificate and enclosure IP rating for the supplied variant before installation in a classified hazardous area.

Industrial IoT OEM and ODM engineering for custom sensors, wireless devices and IoT gateways

PRODUCT TYPE

Explosion-Proof Industrial Dust Detector

TECHNOLOGY

Laser scattering

TECHNICAL DATA

Technical Specifications — HANS IGDV2-PM

Manufacturer modelSD123-IGDV2-PM
HANS catalog modelIGDV2-PM
Device typeExplosion-proof industrial particulate / dust detector
Detection principleLaser scattering
Measured parametersPM2.5, PM10, TSP
PM2.5 measurement range0–20 mg/m³
PM10 measurement range0–60 mg/m³
TSP measurement range0–1000 mg/m³
Concentration resolution0–10 mg/m³: 0.01 mg/m³; 0–100 mg/m³: 0.1 mg/m³; 0–1000 mg/m³: 1 mg/m³
Response time≤15 s
Explosion protection typeFlameproof / Ex d; manufacturer-stated marking: Ex dII CT6 (retain as printed; verify exact certificate marking before hazardous-area deployment)
Ingress protectionIP65/IP66 (manufacturer page lists both ratings; exact enclosure variant/rating requires confirmation)
Supply voltageDC 6–28 V
Power consumption≤3 W
Digital outputRS485, Modbus-RTU
Analog outputDual-channel 4–20 mA (per supplied product page)
Alarm outputRelay output; audible/visual alarm interface
Modbus functions03 (read registers), 06 (write single register)
Baud rate1200–115200 bps; default 9600 bps
Maximum transmission distance≤1000 m (manufacturer-stated)
Operating temperature−20 °C to +85 °C
Operating humidity0–90% RH, non-condensing
Ambient pressure86–106 kPa
InstallationWall-mounted
Explosion-proof cable entryM20 × 1.5 internal thread
4–20 mA cable recommendationShielded cable ≥1.5 mm² × 3; cable outer diameter 6–9 mm
RS485 cable recommendationShielded cable ≥1.5 mm² × 4; cable outer diameter 6–9 mm
Dimensions230 × 178 × 90 mm
Weight≤2 kg
Local displayDigital tube display; cyclic PM2.5 / PM10 / TSP readings
Status indicatorsGreen: normal; red: alarm; yellow: fault
Alarm configurationIndependent high/low thresholds and interval alarm settings for PM2.5, PM10 and TSP; offset correction configurable

Wiring: V/G = DC positive/negative; A1/B1 = RS485 A/B; two 4–20 mA analog channels; relay alarm contacts; external audible/visual alarm interface. Follow the terminal markings on the actual unit and the manufacturer's explosion-proof installation instructions. Unused flameproof cable entries must retain approved stopping plugs and seals.

Certification note: The product page states Ex dII CT6 and cites GB 3836.1-2010 / GB 3836.2-2010, but the certificate number, certificate validity, exact gas/dust group and temperature-class marking have not been independently verified from a certificate document. The page also lists IP65/IP66; do not select one rating without confirming the supplied enclosure.

Source: Manufacturer product page https://www.123iot.cn/ProductDetail/12346840.html; linked manual: https://www.123iot.cn/DownLoad/280775.html?urlStatus=1&a=download. Listed PM ranges, dual analog output and alarm functions are retained as manufacturer-stated data.

SPECIFICATIONS

Technical Specifications — HANS IGDV2-PM

Manufacturer modelSD123-IGDV2-PM
HANS catalog modelIGDV2-PM
Device typeExplosion-proof industrial particulate / dust detector
Detection principleLaser scattering
Measured parametersPM2.5, PM10, TSP
PM2.5 measurement range0–20 mg/m³
PM10 measurement range0–60 mg/m³
TSP measurement range0–1000 mg/m³
Concentration resolution0–10 mg/m³: 0.01 mg/m³; 0–100 mg/m³: 0.1 mg/m³; 0–1000 mg/m³: 1 mg/m³
Response time≤15 s
Explosion protection typeFlameproof / Ex d; manufacturer-stated marking: Ex dII CT6 (retain as printed; verify exact certificate marking before hazardous-area deployment)
Ingress protectionIP65/IP66 (manufacturer page lists both ratings; exact enclosure variant/rating requires confirmation)
Supply voltageDC 6–28 V
Power consumption≤3 W
Digital outputRS485, Modbus-RTU
Analog outputDual-channel 4–20 mA (per supplied product page)
Alarm outputRelay output; audible/visual alarm interface
Modbus functions03 (read registers), 06 (write single register)
Baud rate1200–115200 bps; default 9600 bps
Maximum transmission distance≤1000 m (manufacturer-stated)
Operating temperature−20 °C to +85 °C
Operating humidity0–90% RH, non-condensing
Ambient pressure86–106 kPa
InstallationWall-mounted
Explosion-proof cable entryM20 × 1.5 internal thread
4–20 mA cable recommendationShielded cable ≥1.5 mm² × 3; cable outer diameter 6–9 mm
RS485 cable recommendationShielded cable ≥1.5 mm² × 4; cable outer diameter 6–9 mm
Dimensions230 × 178 × 90 mm
Weight≤2 kg
Local displayDigital tube display; cyclic PM2.5 / PM10 / TSP readings
Status indicatorsGreen: normal; red: alarm; yellow: fault
Alarm configurationIndependent high/low thresholds and interval alarm settings for PM2.5, PM10 and TSP; offset correction configurable

Wiring: V/G = DC positive/negative; A1/B1 = RS485 A/B; two 4–20 mA analog channels; relay alarm contacts; external audible/visual alarm interface. Follow the terminal markings on the actual unit and the manufacturer's explosion-proof installation instructions. Unused flameproof cable entries must retain approved stopping plugs and seals.

Certification note: The product page states Ex dII CT6 and cites GB 3836.1-2010 / GB 3836.2-2010, but the certificate number, certificate validity, exact gas/dust group and temperature-class marking have not been independently verified from a certificate document. The page also lists IP65/IP66; do not select one rating without confirming the supplied enclosure.

Source: Manufacturer product page https://www.123iot.cn/ProductDetail/12346840.html; linked manual: https://www.123iot.cn/DownLoad/280775.html?urlStatus=1&a=download. Listed PM ranges, dual analog output and alarm functions are retained as manufacturer-stated data.

KEY FEATURES

  • Laser-scattering measurement of PM2.5, PM10 and TSP.
  • Manufacturer-stated flameproof marking Ex dII CT6.
  • RS485 Modbus-RTU and dual-channel 4–20 mA outputs.
  • Relay alarm output and external audible/visual alarm interface.
  • Local digital display and keypad parameter configuration.
  • Remote reading and configuration using Modbus functions 03 and 06.
  • Configurable high/low and interval alarm thresholds.
  • DC 6–28 V supply; power consumption ≤3 W.
  • Wall-mounted enclosure with M20 × 1.5 cable-entry thread.

PRODUCT SYSTEM

Available Specifications

HANS IGDV2-PM Explosion-Proof Dust Detector

Model:

IGDV2-PM

​

View Specifications