Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

SL05V2 Liquid Level Transmitter
Industrial IoT
Level Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SL05V2
Model: SL05V2
Specification: HANS-SL05V2 Wired Display Explosion-Proof Level Sensor
Measurement range: Liquid level 0.5–100m configurable
Accuracy: ±0.1%FS, ±0.2%FS, or ±0.5%FS variants (0.5% default)
Power supply: DC11–24V
Communication: 4–20mA, 0–5VDC or RS485 variants
Operating temperature: −40 to +85°C

SONPK01 Soil NPK Sensor
Industrial IoT
Soil NPK Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SONPK01
SONPK01 soil nitrogen/phosphorus/potassium sensor V1.0: N/P/K each reported in mg/kg; range 0–1999mg/kg; accuracy ±3%; resolution 1mg/kg, though source also parenthetically prints mg/L (retain this unit wording difference). Supply DC5–24V; RS485 Modbus RTU default address 01 and 9600bps 8N1; work 0…50°C; stabilization 1s, response <10s. Probe length 55mm, diameter 3mm, 316L stainless steel; IP68 sealed ABS/epoxy; standard cable 2m customizable up to 1200m. This is not an EC, pH or ORP sensor.

SOORP01 Soil ORP Sensor
Industrial IoT
Soil ORP Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOORP01
Model: SOORP01
Specification: HANS-SOORP01 Soil ORP Sensor
Measurement range: −1999 to +1999mV
Accuracy: ±1mV
Resolution: 1mV
Power supply: 5–24VDC for 0–2V/RS485; 12–24VDC for 0–5V/0–10V/4–20mA; optional 3.3–5VDC custom
Output signal: Selectable 0–2V, 0–5V or 0–10V; 4–20mA; RS485 Modbus RTU
Operating temperature: 0–60°C; humidity ≤85%RH

SOPH02 Soil pH Sensor
Industrial IoT
Soil Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOPH02
SOPH02 V1.0 soil pH: pH 3–10, accuracy ±0.2pH, resolution 0.01pH, stability ≤0.02pH/24h. Analog 0–2V, 0–5V, 0–10V or 4–20mA, alternatively RS485 Modbus RTU default address 01 and baud 9600 8N1. Power 7–24V DC for 0–2V/RS485; 12–24V DC for 0–5V/0–10V/4–20mA, optional custom 3.3–5VDC. Operation −30…70°C, RH≤100%, power ≤0.5W.
Independent p.3027 conversion formulas: 0–2V pH=3.5×V+3; 0–5V pH=1.4×V+3; 0–10V pH=0.7×V+3; 4–20mA pH=0.4375×I(mA)+1.25. Modbus address changing via function 06 and register 0x0030. Preserve distinct pH identity, not ORP or EC.

SOTH02 Soil Temperature & Moisture Sensor
Industrial IoT
Soil Temperature & Moisture Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOTH02
Model: SOTH02
Specification: HANS-SOTH02 Soil Temperature and Moisture Sensor
Measurement range: Soil moisture 0–100%; temperature −70 to +150°C (high-accuracy temperature span 0–50°C)
Accuracy: Soil moisture typical 3%; temperature typical ±0.5°C or optional high-precision ±0.1°C
Resolution: Soil moisture 0.1%; temperature 0.1°C
Power supply: DC8–28V
Communication: RS485
Operating temperature: −40 to +85°C

SOTHE01 Soil Temperature, Moisture & EC Sensor
Industrial IoT
Soil Temperature, Moisture & EC Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOTHE01
Model: SOTHE01
Specification: HANS-SOTHE01 Soil Temperature, Moisture and EC Sensor
Measurement range: Temperature −30 to +70°C (custom ranges available); soil moisture 0–100% VWC (custom ranges available); EC 0–2000, 0–10000 or 0–20000μS/cm
Accuracy: Temperature ±0.2°C; moisture ±2% within 0–50% VWC; EC ±2%
Resolution: Temperature 0.1°C; moisture 0.1%; EC 1μS/cm
Power supply: 6–24V DC
Output signal: RS485 Modbus RTU

SOTHE02 Soil Temperature, Moisture & EC Sensor
Industrial IoT
Soil Temperature, Moisture & EC Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOTHE02
Model: SOTHE02
Specification: HANS-SOTHE02 Soil Temperature, Moisture and EC Sensor
Measurement range: Soil moisture 0–100%; temperature −70 to +150°C (high-accuracy span 0–50°C); EC 0–655.35mS/cm
Accuracy: Soil moisture typical 3%; temperature typical ±0.5°C or optional ±0.1°C; EC typical 3%
Resolution: Soil moisture 0.1%; temperature 0.004°C; EC 0.01mS/cm
Power supply: DC8–28V
Communication: RS485
Output signal: RS485 Modbus RTU
Operating temperature: −40 to +85°C

SOTHES01 Soil Temperature, Moisture, EC & Salinity Sensor
Industrial IoT
Soil Multi-Parameter Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOTHES01
SOTHES01 soil temperature, moisture, EC and salinity V1.0: Soil temperature −30…70°C (custom option), moisture 0–100% VWC, EC/salinity ranges 0–2000, 0–10000 or 0–20000μS/cm (variant selectable). Accuracy ±0.2°C, ±2% VWC in 0–50% moisture range and ±2% for EC/salinity. Resolution 0.1°C, 0.1% VWC and 1μS/cm. Supply 6–24VDC, RS485 Modbus RTU default address 01, working −30…70°C, stabilization 3s, response <1s. 55mmר3mm 316L probe, IP68; standard 2m cable, customizable up to 1200m. It reports both EC and temperature-compensated salinity, not soil pH.

SOTHS01 Soil Temperature, Moisture & pH Sensor
Industrial IoT
Soil Multi-Parameter Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOTHS01
SOTHS01 soil temperature, volumetric moisture and pH V1.0: Temperature −30…70°C, optional ranges; moisture 0–100% VWC with 30%, 50% or custom range options; soil pH 3–10. Accuracies ±0.2°C, ±2% VWC within 0–50%, and source-stated ±1 for pH (do not silently replace with SOPH02 accuracy). Resolutions 0.1°C, 0.1% VWC and 0.01pH. Supply DC7–24V; RS485 Modbus RTU default address 01 at 9600 8N1; work −30…70°C, stabilization 3s and response <1s. 55mmר3mm 316L probe, IP68 ABS/epoxy, 2m standard cable, customizable up to 1200m.

SOWT01 Soil Temperature & Moisture Sensor
Industrial IoT
Soil Temperature & Moisture Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SOWT01
Model: SOWT01
Specification: HANS-SOWT01 Soil Temperature and Moisture Sensor
Measurement range: Soil temperature −30 to +70°C; soil volumetric moisture 0–100% (30% or 50% range configurations available)
Accuracy: Temperature ±0.2°C; moisture ±2% VWC in 0–50% moisture range
Power supply: DC5–24V for 0–2V and RS485; DC12–24V for 0–5V, 0–10V and 4–20mA
Communication: Configurable 0–2V / 0–5V / 0–10V analog, 4–20mA, or RS485
Operating temperature: −30 to +70°C

SP Zigbee Wireless Explosion-Proof Pressure Sensor
Industrial IoT
Pressure Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SP
Model: HANS-SP V1.0 Zigbee wireless explosion-proof pressure sensor.
Pressure: Range 0–100 MPa, selectable within range; accuracy ±0.5% FS standard, ±0.1% FS optional; overload capacity 2 × full scale.
Power: 3.6 V, 38 Ah lithium thionyl chloride battery; sleep current <15 μA; operating current 1.5 years.
Environment and construction: Operating temperature -40 to 85°C; IP68; high-definition LCD; die-cast aluminum alloy enclosure with epoxy coating and sealed design; vertical or horizontal mounting; default M20 × 1.5 thread, other threads customizable.
Media and radio: Water is the factory default; oil, gas and other media compatible with 316 stainless steel are supported. Zigbee wireless; supports Zigbee PRO 2007 and mesh topologies. Device ID/network ID/channel are generated according to the oil-well name or specified identifier.

SP01V2 General-Purpose Pressure Transmitter
Industrial IoT
Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
Diffused silicon; hardware/software filtering; temperature compensation
SPECIFICATIONS
SP01V2
Additional dedicated V1.0 manual evidence (组合1 p.2341–2351): Exact cover identifies HANS-SP01V2. Pressure ranges 0–1.6MPa and 0–2.5MPa; other ranges customizable. Pressure types: gauge, absolute and sealed gauge. Overload capacity: below 40MPa, 150%; at/above 40MPa, 120%. Accuracy 0.5%FS; long-term stability ±0.1%FS/year. Dimensions Ø81 × 131 × 47mm; weight approximately 270g. Supply 9–28V; constant-current excitation 750μA. Outputs are 4–20mA or RS485 (optional). Working temperature -40 to +85°C; response speed 5Hz–2.4KHz. Media: air, water and oil that do not corrode stainless steel. Housing 304 stainless steel; connector PVE engineering plastic or 304 stainless steel. RS485 version uses Modbus RTU, 8 data bits, no parity, 1 stop bit, CRC; baud 1200/2400/4800/9600/38400/57600/115200bps (default 9600); address default 1. The manual says only function 0x03 is used for reading register data, while address and baud settings use 0x06 writes. Registers 0x0000–0x0006 provide address, baud, pressure unit, decimal places, measured pressure, range zero and range full. Baud changes require power cycling. Separate wiring definitions are provided for 4–20mA and RS485 configurations.
Commercial selection: 4–20 mA ranges: 0–6 kPa; 0–10 kPa; 0–16 kPa; 0–25 kPa; 0–40 kPa; 0–60 kPa; 0–0.1 MPa; 0–0.16 MPa; 0–0.25 MPa; 0–0.4 MPa; 0–0.6 MPa; 0–1.0 MPa; 0–1.6 MPa; 0–2.5 MPa; 0–4.0 MPa; 0–6 MPa; 0–10 MPa; 0–16 MPa; 0–25 MPa; 0–40 MPa; 0–60 MPa; 0–100 MPa; −0.1 to 0 MPa; −0.1 to +0.1 MPa. Optional RS485, LCD, high-temperature, flush-diaphragm sanitary and waterproof cable-out configurations are subject to order-specific confirmation. Standard accuracy 0.5% FS; 0.2% upgrade listed commercially. Do not assume all options can be combined. Dimensions vary or conflict in historical documentation; confirm drawing before ordering.
Manufacturer commercial selection: The supplied manufacturer storefront listing corroborates all 24 ranges, 9–28 VDC supply, standard 0.5% FS accuracy, optional 0.2% accuracy, −40 to +85°C standard operating environment, 5 Hz–2.4 kHz response, 304 stainless steel housing and compatible air, water and oil. The RS485 version has no display. A digital-display head, high-temperature version and waterproof cable outlet are separately selectable; exact configuration limits must be confirmed. The commercial listing does not establish a high-temperature limit or waterproof IP rating.
Electrical connection and integration
Hirschmann connector: analog version pin 1 supply positive, pin 2 supply negative; RS485 version additionally pin 3 A and pin 4 B. Nominal wiring diagram uses 24 VDC within the 9–28 VDC supply range. RS485: 8N1, CRC, default address 1 and 9600 bps. Register 0x0000 address, 0x0001 baud, 0x0002 unit, 0x0003 decimal places, 0x0004 measured pressure, 0x0005 lower range, 0x0006 upper range. Read with 0x03; write address and baud with 0x06. Pressure and range values are signed 16-bit; scale by decimal places. Baud code 4 maps to 19200 bps in the register table but is omitted from the general baud list; verify on hardware. Power cycle after changing baud.
Display variant: 4½-digit display, yellow backlight, local zero adjustment. RS485 variant has no display. Install horizontally or vertically; tighten using the process fitting rather than the display housing, keep the process line clean and never exceed rated pressure. Manual V1.0, 2022-06-08, pp. 4–10.

SP06 Differential Pressure Transmitter
Industrial IoT
Differential Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SP06
SP06 V1.1 dedicated Modbus mapping, 组合1 p.3240–3243: RS485 half-duplex Modbus RTU, serial 8 data bits/no parity/1 stop bit, supported baud 1200/2400/4800/9600/19200/38400/57600/115200, CRC16 polynomial 0xA001. Function 03 reads, function 06 writes. Read registers: 0x0000 device address (1–255); 0x0001 baud code 0–7; 0x0002 pressure unit (published list includes CM, MM, MPa, Pa, kPa, mA, bar, psi, mmHg, mH2O, %, M); 0x0003 decimal digits 0–3; 0x0004 measured output signed int16; 0x0005 range zero; 0x0006 range full. Only address 0x0000 and baud code 0x0001 are documented writable; respond at old address/baud before changing. Data uses signed 16-bit and decimal scaling, not an inferred float register. Warm-up approximately 30 minutes for stable output. Keep RS485, 4–20mA 2-wire and voltage 3-wire as separate order-specific outputs, not simultaneous.

SP07V2 Smart Digital Pressure Gauge
Industrial IoT
Digital Pressure Gauge
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Model: HANS-SP07V2
Measuring range: 0–60 MPa; select the required configuration.
Pressure types: Gauge, absolute or sealed gauge.
Accuracy: ±0.4%; long-term stability 0.2% FS/year.
Overload: 150% FS below 40 MPa; 120% FS at or above 40 MPa.
Power: 3 V, two AAA batteries; battery life at least six months depending on operating conditions.
Sampling: 3 samples/s. Display: 4½-digit segment LCD, backlight, MAX/MIN peak recording.
Construction: 304 stainless steel body and connector; Ø81 × 131 × 47 mm; approx. 440 g.
Media: Compatible gases, water and oil. Confirm media compatibility, pressure type and process connection before ordering.

SP12 Differential Pressure Transmitter
Industrial IoT
Differential Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SP12
Model: SP12
Specification: HANS-SP12 Differential Pressure Transmitter
Measurement range: Differential pressure −100 kPa to +3 MPa (configurable ranges)
Accuracy: ±0.2% standard; ±0.5% or ±0.1% options
Power supply: DC12–24V
Communication: 4–20mA current loop with HART bus
Operating temperature: −20 to +70°C

SP15 Single-Crystal Silicon Intelligent Pressure Transmitter
Industrial IoT
Smart Pressure Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SP15
Model: HANS-SP15 intelligent monocrystalline silicon differential-pressure transmitter, V1.0.
Pressure: Range 0 kPa–20 MPa; any one side may withstand 0–8 MPa overpressure without damage; damping time constant adjustable in 0.1 s increments from minimum to 32 s; static pressure operating range 8 MPa. Accuracy ±0.2% calibrated span; six-month long-term stability ±0.5% URL; temperature drift ±0.5% URL + 0.2% calibrated span per 56°C.
Electrical: DC 9–32 V; 4–20 mA current output with HART communication; transmitter weight approximately 3.3 kg.
Media and environment: Liquid, gas and steam; medium temperature -40 to 104°C; operating environment -20 to 70°C and 0–100% RH.
Installation: M20 × 1.5 process connection; 316L stainless steel wetted material; installation and wiring as shown in the manual.
Identity note: The manual cover and technical table identify SP15. The product overview page contains one SP12 typo; it is retained as a source typo and does not change the model identity.

SRT01-A NB-IoT Indoor Temperature Collector
Industrial IoT
Indoor Temperature Collector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SRT01-A
Model: HANS-SRT01-A V1.0, telecom AEP version, socket-type indoor room-temperature collector for heating-balance systems.
Measurement: Indoor temperature range 0–45°C; accuracy ±0.5°C. NB-IoT data transmission to the heating platform.
Electrical: AC 220 V supply; standby power <0.5 W; load current 10 A; maximum power 200 W. Working temperature 0–50°C; storage temperature -20 to 50°C.
Local functions: Infrared communication for local configuration using a mobile app; display shows indoor temperature, signal, communication and fault status; measurement fault alarms can be uploaded to the heating platform.
Physical: Fixed socket installation; dimensions 86.4 × 90.3 × 40.5 mm; installation spacing 60.3 mm.

ST01V2 Analog Temperature & Humidity Transmitter
Industrial IoT
Temperature & Humidity Transmitter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ST01V2
Model: HANS-ST01V2 V1.0 analog temperature/humidity transmitter, Sensirion SHT30. Temperature -40…+80°C with typical ±0.5°C at 25°C; RH 0–100% with ±3% at 25°C and airflow 1m/s. Long-term stability humidity <1%/year, temperature <0.1°C/year.
Supply/output: DC10–24V depending on current-load conditions, power <1W. 4–20mA or 0–10V analog outputs; no RS485 interface is stated. Six-wire default: red supply positive, black ground, green temperature analog positive, blue temperature analog negative, yellow humidity analog positive, white humidity analog negative. Actual cable labels on the individual device govern wiring.
4–20mA scaling: temperature (°C)=(I[mA]−4)×7.5−40; RH (%)=(I[mA]−4)×6.25. 0–10V scaling: temperature (°C)=12×V−40; RH (%)=10×V. Wall mount, 110×85×44mm; IP65.
- Page 11