top of page

HANS Industrial IoT Systems

Request a Quote

SP06 Differential Pressure Transmitter

SP06 is a differential-pressure transmitter for measuring pressure difference across equipment or components. Source specifications provide ±100Pa through ±100kPa range options, RS485, 4–20mA and voltage outputs, 9–36VDC supply and IP65 protection.

Industrial IoT OEM and ODM engineering for custom sensors, wireless devices and IoT gateways
HANS Differential Pressure Transmitter — representative product category image

PRODUCT TYPE

Differential Pressure Transmitter

TECHNOLOGY

​

TECHNICAL DATA

SP06 V1.1 dedicated Modbus mapping, 组合1 p.3240–3243: RS485 half-duplex Modbus RTU, serial 8 data bits/no parity/1 stop bit, supported baud 1200/2400/4800/9600/19200/38400/57600/115200, CRC16 polynomial 0xA001. Function 03 reads, function 06 writes. Read registers: 0x0000 device address (1–255); 0x0001 baud code 0–7; 0x0002 pressure unit (published list includes CM, MM, MPa, Pa, kPa, mA, bar, psi, mmHg, mH2O, %, M); 0x0003 decimal digits 0–3; 0x0004 measured output signed int16; 0x0005 range zero; 0x0006 range full. Only address 0x0000 and baud code 0x0001 are documented writable; respond at old address/baud before changing. Data uses signed 16-bit and decimal scaling, not an inferred float register. Warm-up approximately 30 minutes for stable output. Keep RS485, 4–20mA 2-wire and voltage 3-wire as separate order-specific outputs, not simultaneous.

SPECIFICATIONS

SP06

SP06 V1.1 dedicated Modbus mapping, 组合1 p.3240–3243: RS485 half-duplex Modbus RTU, serial 8 data bits/no parity/1 stop bit, supported baud 1200/2400/4800/9600/19200/38400/57600/115200, CRC16 polynomial 0xA001. Function 03 reads, function 06 writes. Read registers: 0x0000 device address (1–255); 0x0001 baud code 0–7; 0x0002 pressure unit (published list includes CM, MM, MPa, Pa, kPa, mA, bar, psi, mmHg, mH2O, %, M); 0x0003 decimal digits 0–3; 0x0004 measured output signed int16; 0x0005 range zero; 0x0006 range full. Only address 0x0000 and baud code 0x0001 are documented writable; respond at old address/baud before changing. Data uses signed 16-bit and decimal scaling, not an inferred float register. Warm-up approximately 30 minutes for stable output. Keep RS485, 4–20mA 2-wire and voltage 3-wire as separate order-specific outputs, not simultaneous.

KEY FEATURES

SP06 is a differential-pressure transmitter for measuring pressure difference across equipment or components. Source specifications provide ±100Pa through ±100kPa range options, RS485, 4–20mA and voltage outputs, 9–36VDC supply and IP65 protection.

PRODUCT SYSTEM

Available Specifications

HANS-SP06 Low Differential Pressure Transmitter

Model:

SP06

​

View Specifications
bottom of page