SOPH02 Soil pH Sensor
SOPH02 is a soil pH sensor with a 3–10 pH measurement range, ±0.2 pH accuracy and 0.01 pH resolution. Source documentation supports selectable voltage, 4–20mA and RS485 outputs; RS485 uses standard Modbus RTU at 9600 baud by default.


PRODUCT TYPE
Soil Sensor
TECHNOLOGY
TECHNICAL DATA
Model: SOPH02 — soil pH sensor only.
Measurement: pH 3–10; accuracy ±0.2 pH; resolution 0.01 pH; stability ≤0.02 pH/24 h.
Selectable output: 0–2 V, 0–5 V, 0–10 V, 4–20 mA or RS-485 Modbus/RTU. One output variant is selected per unit. RS-485 default address 01; 9600 bps, no parity, 8 data bits, 1 stop bit.
Power: 7–24 VDC for 0–2 V or RS-485; 12–24 VDC for 0–5 V, 0–10 V or 4–20 mA; optional custom 3.3–5 VDC. Power consumption ≤0.5 W.
Environment and installation: −30 to +70°C; relative humidity ≤100%; zinc-aluminum probe for direct soil insertion. Insert the probe fully and avoid stones and hard soil clods. The manual does not state an IP rating or probe length.
Analog conversion: 0–2 V: pH = 3.5×V + 3; 0–5 V: pH = 1.4×V + 3; 0–10 V: pH = 0.7×V + 3; 4–20 mA: pH = 0.4375×I(mA) + 1.25.
SPECIFICATIONS
SOPH02
SOPH02 V1.0 soil pH: pH 3–10, accuracy ±0.2pH, resolution 0.01pH, stability ≤0.02pH/24h. Analog 0–2V, 0–5V, 0–10V or 4–20mA, alternatively RS485 Modbus RTU default address 01 and baud 9600 8N1. Power 7–24V DC for 0–2V/RS485; 12–24V DC for 0–5V/0–10V/4–20mA, optional custom 3.3–5VDC. Operation −30…70°C, RH≤100%, power ≤0.5W.
Independent p.3027 conversion formulas: 0–2V pH=3.5×V+3; 0–5V pH=1.4×V+3; 0–10V pH=0.7×V+3; 4–20mA pH=0.4375×I(mA)+1.25. Modbus address changing via function 06 and register 0x0030. Preserve distinct pH identity, not ORP or EC.
KEY FEATURES
Soil pH measurement, pH 3–10. Selectable analog voltage, 4–20 mA or RS-485 Modbus/RTU output. The output interface and supply voltage depend on the ordered variant.
PRODUCT SYSTEM