ST01V2 Analog Temperature & Humidity Transmitter

ST01V2 is an analog temperature and humidity transmitter using an SHT30 sensing element. The technical documentation specifies -40–80°C and 0–100%RH ranges, 4–20mA or 0–10V outputs, DC10–24V supply, IP65 enclosure and wall mounting.

Industrial IoT OEM and ODM engineering for custom sensors, wireless devices and IoT gateways
ST01V2 — Reference illustration from product documentation. Verify the exact model, variant, interface and mechanical configuration against the original manufacturer manual before ordering.

PRODUCT TYPE

Temperature & Humidity Transmitter

TECHNOLOGY

​

TECHNICAL DATA

Model: HANS-ST01V2 V1.0 analog temperature/humidity transmitter, Sensirion SHT30. Temperature -40…+80°C with typical ±0.5°C at 25°C; RH 0–100% with ±3% at 25°C and airflow 1m/s. Long-term stability humidity <1%/year, temperature <0.1°C/year.

Supply/output: DC10–24V depending on current-load conditions, power <1W. 4–20mA or 0–10V analog outputs; no RS485 interface is stated. Six-wire default: red supply positive, black ground, green temperature analog positive, blue temperature analog negative, yellow humidity analog positive, white humidity analog negative. Actual cable labels on the individual device govern wiring.

4–20mA scaling: temperature (°C)=(I[mA]−4)×7.5−40; RH (%)=(I[mA]−4)×6.25. 0–10V scaling: temperature (°C)=12×V−40; RH (%)=10×V. Wall mount, 110×85×44mm; IP65.

SPECIFICATIONS

ST01V2

Model: HANS-ST01V2 V1.0 analog temperature/humidity transmitter, Sensirion SHT30. Temperature -40…+80°C with typical ±0.5°C at 25°C; RH 0–100% with ±3% at 25°C and airflow 1m/s. Long-term stability humidity <1%/year, temperature <0.1°C/year.

Supply/output: DC10–24V depending on current-load conditions, power <1W. 4–20mA or 0–10V analog outputs; no RS485 interface is stated. Six-wire default: red supply positive, black ground, green temperature analog positive, blue temperature analog negative, yellow humidity analog positive, white humidity analog negative. Actual cable labels on the individual device govern wiring.

4–20mA scaling: temperature (°C)=(I[mA]−4)×7.5−40; RH (%)=(I[mA]−4)×6.25. 0–10V scaling: temperature (°C)=12×V−40; RH (%)=10×V. Wall mount, 110×85×44mm; IP65.

KEY FEATURES

ST01V2 is an analog temperature and humidity transmitter using an SHT30 sensing element. The technical documentation specifies -40–80°C and 0–100%RH ranges, 4–20mA or 0–10V outputs, DC10–24V supply, IP65 enclosure and wall mounting.

PRODUCT SYSTEM

Available Specifications

HANS-ST01V2 Analog Temperature and Humidity Transmitter

Model:

ST01V2

​

View Specifications
bottom of page