HANS-E70 Multi-Parameter Air Quality Sensor Module
Industrial IoT
Multi-Parameter Air Quality Sensor Module
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
E70
Model: E70
Specification: HANS-E70 Multi-Parameter Air Quality Sensor Module
Measurement range: PM2.5/PM10 0–1000μg/m³; formaldehyde 0–1.5mg/m³; CO2 400–5000ppm; temperature −40 to +120°C; humidity 0–100%RH; pressure 0–120kPa; illuminance 0–200kLux; TVOC 0–5000μg/m³; ozone 0–10ppm; oxygen 0–25%Vol; H2S 0–100ppm; methane 0–100%LEL; CO 0–1000ppm; NO2/SO2 0–20ppm; H2 0–1000ppm; ammonia 0–100ppm; chlorine 0–10ppm
Power supply: Standard 24V DC; supported 10–30V
Communication: RS-485
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted (body-labelled HANS-E60)

HANS-0RP03 Online ORP Water Quality Sensor
Industrial IoT
Online ORP Water Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
This HANS ORP sensor configuration is currently unavailable. Contact HANS Industrial IoT to confirm the correct model designation, measurement range and available configuration before ordering.

HANS-COD03 Online Chemical Oxygen Demand Water Quality Sensor
Industrial IoT
Online Chemical Oxygen Demand (COD) Water Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
COD03
Model: COD03
Specification: HANS-COD03 Online Chemical Oxygen Demand Water Quality Sensor
Measurement range: COD: 0–200mg/L or 0–500mg/L as KHP-equivalent; turbidity: 0–100NTU or 0–200NTU variant
Accuracy: COD ±5%; turbidity ±5%
Resolution: COD 0.1mg/L; turbidity 0.1NTU
Power supply: 12–24V DC
Communication: RS-485
Operating temperature: 0 to +50°C; <0.2MPa
Installation: Submersible installation; 1/2NPT thread; install within 2m of water surface and avoid bubbles at optical window

HANS-FAC01 Wireless Manual Fire Alarm Call Point
Industrial IoT
Wireless Manual Fire Alarm Call Point
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
FAC01
HANS-FAC01 wireless manual fire alarm call point is independently described on 组合1 p.3413 within the three-part FAC02/FAC03/FAC01 installation manual. DC3V; alarm current ≤2mA; red ABS; manual push-button initiation with white operator panel; manual reset by dedicated tool/key; red indicator lights during activated alarm; operating −10…+55°C, relative humidity ≤95% noncondensing; weight 155g; dimensions 85×85×41.5mm; fixing hole spacing 62.5mm. Mount at corridor, staircase or other principal circulation/exit location. Works with paired FAC03 audible/visual alarm unit; do not inherit FAC03's DC12V power, siren, Wi-Fi/LoRa gateway characteristics, or FAC02's 9V optical smoke-detector values.

HANS-CMD03 Air Quality Carbon Monoxide Detector
Industrial IoT
Carbon Monoxide Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
CMD03
Model: CMD03
Specification: HANS-CMD03 Carbon Monoxide Detector
Measurement range: Carbon monoxide (CO): 0–1000 ppm
Power supply: DC 15–28V (non-polarized two-wire bus)
Communication: Non-polarized two-wire bus
Operating temperature: −20 to +40°C
Operating humidity: ≤85% RH
Installation: 86-type wall box; mounting hole spacing 60 mm; recommended installation height 1.6–2.5m

HANS-CMD01 Air Quality Monitoring Controller
Industrial IoT
Air Quality Monitoring Controller
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
CMD01
System role: Central air-quality monitor communicates by RS485 with multiple air-quality controllers; the controller polls CO detectors and drives mechanical supply/exhaust ventilation when CO exceeds limits. The monitor displays and stores controller status and values and can issue reset/configuration operations.
Electrical/environment: AC220V, 50Hz; backup battery supports more than 4 hours; continuous 24-hour operation; RS485; supports up to 32 controllers. Monitors detector CO concentration and fan status. Fault alarm response <60s; sound pressure >70dB at 1m; red LED alarm. Operating environment -10 to +40°C, RH10–95%, altitude ≤3000m. Wall-mounted in a dedicated control/duty room. Display chassis size 385 × 98mm as shown in dimension drawing; separate installation section gives cabinet/body dimensions 400 × 400 × 120mm—preserve these as distinct drawing/installation dimensions.
Wiring/network: Monitor-to-controller RS485 twisted pair ≥1.5mm², maximum distance <1200m; controller-to-detector twisted pair ≥2.5mm², maximum distance <1500m. Screened twisted pair and grounding are recommended in high-interference environments. Main supply L/N, chassis ground FG, RS485 A+/B-, backup battery BAT-/BAT+.
Functions: Displays CO readings and detector addresses, fan status, faults and alarms; logs up to 100,000 historical records; controller registration and device import via CSV; supports status queries, fault reset, self-test, alarm silencing, password-protected advanced configuration and device management.
Identity gate: Technical values are recorded as evidence from this monitoring-host manual only. Do not promote the model identity to fully confirmed until the manufacturer confirms that this VA1.2 document belongs to HANS-CMD01.

HANS-T80-WIFI Temperature and Humidity Logger
Industrial IoT
Wi-Fi Temperature & Humidity Logger
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
1–4 temperature/humidity probes; 2.4 GHz Wi-Fi; OTT-LINK upload; local storage up to 500,000 records; upload interval 5–1,440 minutes; 3.7 V 3,000 mAh rechargeable battery; external DC 10–24 V; USB 5 V charging; internal temperature probe −10 to +60 °C; external temperature probe −40 to +85 °C; humidity 0–100% RH; 120 × 114 × 34 mm wall-mounted enclosure.

HANS-PH03 Online Water pH Sensor
Industrial IoT
Online Water pH Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
PH03
Model: HANS-PH03 V1.0 online digital pH sensor.
Measurement range: 0–14.00 pH. Resolution: 0.01 pH; temperature 0.1°C. Accuracy: ±0.1 pH; temperature ±0.3°C.
Temperature compensation: automatic NTC. Operating conditions: 0–50°C, pressure <0.2MPa. Storage: −5 to +65°C. Power: 12–24VDC; power consumption 0.1W at 12V. Output: RS-485 Modbus RTU. Protection: IP68. Wetted material: POM. Installation: immersion, 1/2NPT; standard cable 5m (custom lengths available).
Modbus: default 9600,n,8,1; function 0x03 reads holding registers; function 0x06 writes single registers. Register 40001 / 0x0000 reads measurement and temperature (4 registers/8 bytes). Calibration: 44097 / 0x1000 zero point at pH 6.86; 44099 / 0x1002 low slope at pH 4.00; 44101 / 0x1004 high slope at pH 9.18; 44113 / 0x1010 temperature calibration. Device address register 48195 / 0x2002 (default 6; range 1–127). Reset register 48225 / 0x2020.

HANS-CLS03 Online Residual Chlorine Sensor
Industrial IoT
Online Residual Chlorine Water Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
This HANS residual-chlorine sensor configuration is currently unavailable. Contact HANS Industrial IoT to confirm the model designation, measurement range and available configuration before ordering.

HANS-DO03 Online Fluorescence Dissolved Oxygen Sensor
Industrial IoT
Online Dissolved Oxygen Water Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DO03
Model: DO03
Specification: HANS-DO03 Online Fluorescence Dissolved Oxygen Sensor
Measurement range: 0–20.00mg/L (0–200% saturation at 25°C)
Accuracy: ±2%; temperature ±0.3°C
Resolution: 0.01mg/L; temperature 0.1°C
Power supply: 12–24V DC
Output signal: RS-485 Modbus RTU
Operating temperature: 0 to +50°C
Installation: Submersible installation; protect fluorescence cap from impact and sediment deposits

HANS-ZS03 Online Water Turbidity Sensor
Industrial IoT
Online Water Turbidity Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ZS03
Model: ZS03
Specification: HANS-ZS03 Online Water Turbidity Sensor
Measurement range: 0–100 NTU or 0–1000 NTU variant
Accuracy: ±3% or ±3 NTU (whichever is larger); temperature ±0.5°C
Resolution: 0.1 NTU; temperature 0.1°C
Power supply: 12–24V DC
Communication: RS-485
Operating temperature: 0 to +50°C
Installation: Submersible; 1/2 NPT thread

HANS-SCB Online Self-Cleaning Bracket
Industrial IoT
Self-Cleaning Sensor Bracket
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
SCB
Model: SCB
Specification: HANS-SCB Online Self-Cleaning Bracket
Power supply: 12–24V DC
Operating temperature: −5 to +50°C
Installation: 3/4 NPT top thread for fixed installation; sensors mounted around bracket

HANS-EC03 Online Water Conductivity Sensor
Industrial IoT
Online Water Conductivity Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
EC03
Model: EC03
Specification: HANS-EC03 Online Water Conductivity Sensor
Measurement range: 0–5000 μS/cm
Accuracy: ±1.5%; temperature ±0.5°C
Resolution: 1 μS/cm; temperature 0.1°C
Power supply: 12–24V DC
Communication: RS-485
Operating temperature: 0 to +50°C
Installation: Submersible; 1/2 NPT thread

HANS-G30-SF6+O2 Multi-Gas Sensor
Industrial IoT
SF6, Oxygen and Ozone Gas Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
G30-SF6+O2
Model: G30-SF6+O2
Specification: HANS-G30-SF6+O2 Multi-Gas Sensor
Measurement range: SF6 0–3000ppm; O2 0–25%VOL; O3 0–10ppm
Accuracy: SF6 ±1%; O2 ±0.5%VOL; O3 ±2%
Resolution: SF6 0.1ppm; O2 0.1%VOL; O3 0.1ppm
Power supply: DC 24V
Communication: RS-485

HANS-FAC Fire Alarm Controller
Industrial IoT
Fire Alarm Controller
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
FAC
Model: HANS-FAC fire alarm controller (central controller, not a detector, manual call point or standalone smoke alarm).
System: All-two-wire bus, distributed intelligent fire alarm system with front-end devices, loop polling/event reporting, alarm and supervisory event handling, and optional linkage control. 3.2-inch TFT color LCD. Stores 10,000 operating records, 3,000 fire alarm records, 3,000 linkage records and 3,000 fault records.
Power: Main supply AC220V (+10%/-15%), 50Hz ±5%, 1A; backup DC12V sealed maintenance-free battery. Power consumption 5W monitoring, <8W alarm. Automatic main/backup switching and backup undervoltage protection. Manual says backup can operate for up to 8 hours before shutdown/protection.
Capacity: One wired loop; the technical table lists 64-, 128- and 248-point capacity versions. The terminology section separately says one loop supports a maximum of 64 points. Preserve this internal capacity/loop wording discrepancy; confirm exact loop/point architecture for the ordered version.
Environment/mechanical: Operating temperature -10 to +40°C; relative humidity ≤93% at 40±2°C, non-condensing. Wall mounted; dimensions 385 × 297 × 98mm.
Interfaces/outputs: Non-polarized two-wire alarm loop. HJ fire alarm output and GZ fault output are normally-open dry-contact relays. RS485 communication output; CANH/CANL controller interconnection; reserved terminals; Z+/Z- loop bus; AC L/N/E mains input. Wiring drawing identifies 24V output terminals but their detailed role is not specified in the parameter table.
Wiring/installation: Recommended ZR-RVS fire-retardant twisted-pair copper cable ≥1.0mm² (1.5mm² recommended); maximum line distance 1000m; total conductor resistance <40Ω and capacitance <0.3μF. Solder and insulate joints. Independent earth resistance ≤4Ω; common earth ≤1Ω. Install in a staffed fire-control room.
Operations: One- and two-level password access; device registration, bus device type/location setup, linkage programming, wireless-device registration, event history, relay/module operation, indicator confirmation and external sounder control. Default user/programming passwords are both 0000; manual instructs changing them.
Compliance: Manual cites GB 4717-2005 and GB 50116-2013. These are source-listed standards, not a separate certificate claim.
Configuration boundary: Capacity variant, loop architecture, optional printer, communication/linkage and connected front-end devices must be confirmed for the delivered controller. Do not merge with FAC01 wireless manual call point or FAC02 standalone photoelectric smoke alarm.