HANS-PH03 Online Water pH Sensor
HANS-PH03 is an online digital pH sensor for water-quality monitoring in acid, alkali and salt solutions, chemical reaction processes and industrial production. It measures 0-14.00 pH with 0.01 pH resolution and +/-0.1 pH accuracy, with automatic NTC temperature compensation. The probe uses RS-485 Modbus RTU, operates from 12-24 VDC, and is rated IP68 for immersion installation with a 1/2 NPT thread and a 5 m standard cable. The V1.0 manual documents zero calibration at pH 6.86 and slope calibration at pH 4.00 and 9.18. Protocol/register details are documented; live instrument communication has not been tested.


PRODUCT TYPE
Online Water pH Sensor
TECHNOLOGY
TECHNICAL DATA
Model: HANS-PH03 V1.0 online digital pH sensor.
Measurement range: 0–14.00 pH. Resolution: 0.01 pH; temperature 0.1°C. Accuracy: ±0.1 pH; temperature ±0.3°C.
Temperature compensation: automatic NTC. Operating conditions: 0–50°C, pressure <0.2MPa. Storage: −5 to +65°C. Power: 12–24VDC; power consumption 0.1W at 12V. Output: RS-485 Modbus RTU. Protection: IP68. Wetted material: POM. Installation: immersion, 1/2NPT; standard cable 5m (custom lengths available).
Modbus: default 9600,n,8,1; function 0x03 reads holding registers; function 0x06 writes single registers. Register 40001 / 0x0000 reads measurement and temperature (4 registers/8 bytes). Calibration: 44097 / 0x1000 zero point at pH 6.86; 44099 / 0x1002 low slope at pH 4.00; 44101 / 0x1004 high slope at pH 9.18; 44113 / 0x1010 temperature calibration. Device address register 48195 / 0x2002 (default 6; range 1–127). Reset register 48225 / 0x2020.
SPECIFICATIONS
PH03
Model: HANS-PH03 V1.0 online digital pH sensor.
Measurement range: 0–14.00 pH. Resolution: 0.01 pH; temperature 0.1°C. Accuracy: ±0.1 pH; temperature ±0.3°C.
Temperature compensation: automatic NTC. Operating conditions: 0–50°C, pressure <0.2MPa. Storage: −5 to +65°C. Power: 12–24VDC; power consumption 0.1W at 12V. Output: RS-485 Modbus RTU. Protection: IP68. Wetted material: POM. Installation: immersion, 1/2NPT; standard cable 5m (custom lengths available).
Modbus: default 9600,n,8,1; function 0x03 reads holding registers; function 0x06 writes single registers. Register 40001 / 0x0000 reads measurement and temperature (4 registers/8 bytes). Calibration: 44097 / 0x1000 zero point at pH 6.86; 44099 / 0x1002 low slope at pH 4.00; 44101 / 0x1004 high slope at pH 9.18; 44113 / 0x1010 temperature calibration. Device address register 48195 / 0x2002 (default 6; range 1–127). Reset register 48225 / 0x2020.
KEY FEATURES
- pH measurement range: 0-14.00 pH; resolution 0.01 pH; accuracy +/-0.1 pH.
- Automatic NTC temperature compensation; temperature accuracy +/-0.3 C.
- RS-485 Modbus RTU; default 9600 bps, 8 data bits, no parity, 1 stop bit.
- 12-24 VDC; 0.1 W at 12 V.
- IP68 protection; POM wetted material; 1/2 NPT immersion mounting.
- 5 m standard cable; custom cable lengths available.
- Two-point calibration workflow: zero at pH 6.86; slope at pH 4.00 and pH 9.18.
- Manual includes measurement, temperature, calibration, device-address and reset registers; no live device test has been performed.