HANS-FAC Fire Alarm Controller
HANS-FAC Fire Alarm Controller is listed in the HANS Industrial IoT product catalog as a fire alarm controller under Safety & Smart Infrastructure Monitoring. Measurement range: One addressable loop; available system capacities 64, 128 or 248 points (variant-dependent). Power supply: Mains AC220V (+10%, -15%), 50Hz ±5%, 1A; backup DC12V sealed maintenance-free battery. Communication: Non-polarized two-wire fire alarm bus; RS485 alarm/event output; CAN master/slave controller networking. Operating temperature: −10 to +40°C. Reference information only; model configuration and availability are subject to confirmation before ordering.


PRODUCT TYPE
Fire Alarm Controller
TECHNOLOGY
TECHNICAL DATA
Model: HANS-FAC fire alarm controller (central controller, not a detector, manual call point or standalone smoke alarm).
System: All-two-wire bus, distributed intelligent fire alarm system with front-end devices, loop polling/event reporting, alarm and supervisory event handling, and optional linkage control. 3.2-inch TFT color LCD. Stores 10,000 operating records, 3,000 fire alarm records, 3,000 linkage records and 3,000 fault records.
Power: Main supply AC220V (+10%/-15%), 50Hz ±5%, 1A; backup DC12V sealed maintenance-free battery. Power consumption 5W monitoring, <8W alarm. Automatic main/backup switching and backup undervoltage protection. Manual says backup can operate for up to 8 hours before shutdown/protection.
Capacity: One wired loop; the technical table lists 64-, 128- and 248-point capacity versions. The terminology section separately says one loop supports a maximum of 64 points. Preserve this internal capacity/loop wording discrepancy; confirm exact loop/point architecture for the ordered version.
Environment/mechanical: Operating temperature -10 to +40°C; relative humidity ≤93% at 40±2°C, non-condensing. Wall mounted; dimensions 385 × 297 × 98mm.
Interfaces/outputs: Non-polarized two-wire alarm loop. HJ fire alarm output and GZ fault output are normally-open dry-contact relays. RS485 communication output; CANH/CANL controller interconnection; reserved terminals; Z+/Z- loop bus; AC L/N/E mains input. Wiring drawing identifies 24V output terminals but their detailed role is not specified in the parameter table.
Wiring/installation: Recommended ZR-RVS fire-retardant twisted-pair copper cable ≥1.0mm² (1.5mm² recommended); maximum line distance 1000m; total conductor resistance <40Ω and capacitance <0.3μF. Solder and insulate joints. Independent earth resistance ≤4Ω; common earth ≤1Ω. Install in a staffed fire-control room.
Operations: One- and two-level password access; device registration, bus device type/location setup, linkage programming, wireless-device registration, event history, relay/module operation, indicator confirmation and external sounder control. Default user/programming passwords are both 0000; manual instructs changing them.
Compliance: Manual cites GB 4717-2005 and GB 50116-2013. These are source-listed standards, not a separate certificate claim.
Configuration boundary: Capacity variant, loop architecture, optional printer, communication/linkage and connected front-end devices must be confirmed for the delivered controller. Do not merge with FAC01 wireless manual call point or FAC02 standalone photoelectric smoke alarm.
SPECIFICATIONS
FAC
Model: HANS-FAC fire alarm controller (central controller, not a detector, manual call point or standalone smoke alarm).
System: All-two-wire bus, distributed intelligent fire alarm system with front-end devices, loop polling/event reporting, alarm and supervisory event handling, and optional linkage control. 3.2-inch TFT color LCD. Stores 10,000 operating records, 3,000 fire alarm records, 3,000 linkage records and 3,000 fault records.
Power: Main supply AC220V (+10%/-15%), 50Hz ±5%, 1A; backup DC12V sealed maintenance-free battery. Power consumption 5W monitoring, <8W alarm. Automatic main/backup switching and backup undervoltage protection. Manual says backup can operate for up to 8 hours before shutdown/protection.
Capacity: One wired loop; the technical table lists 64-, 128- and 248-point capacity versions. The terminology section separately says one loop supports a maximum of 64 points. Preserve this internal capacity/loop wording discrepancy; confirm exact loop/point architecture for the ordered version.
Environment/mechanical: Operating temperature -10 to +40°C; relative humidity ≤93% at 40±2°C, non-condensing. Wall mounted; dimensions 385 × 297 × 98mm.
Interfaces/outputs: Non-polarized two-wire alarm loop. HJ fire alarm output and GZ fault output are normally-open dry-contact relays. RS485 communication output; CANH/CANL controller interconnection; reserved terminals; Z+/Z- loop bus; AC L/N/E mains input. Wiring drawing identifies 24V output terminals but their detailed role is not specified in the parameter table.
Wiring/installation: Recommended ZR-RVS fire-retardant twisted-pair copper cable ≥1.0mm² (1.5mm² recommended); maximum line distance 1000m; total conductor resistance <40Ω and capacitance <0.3μF. Solder and insulate joints. Independent earth resistance ≤4Ω; common earth ≤1Ω. Install in a staffed fire-control room.
Operations: One- and two-level password access; device registration, bus device type/location setup, linkage programming, wireless-device registration, event history, relay/module operation, indicator confirmation and external sounder control. Default user/programming passwords are both 0000; manual instructs changing them.
Compliance: Manual cites GB 4717-2005 and GB 50116-2013. These are source-listed standards, not a separate certificate claim.
Configuration boundary: Capacity variant, loop architecture, optional printer, communication/linkage and connected front-end devices must be confirmed for the delivered controller. Do not merge with FAC01 wireless manual call point or FAC02 standalone photoelectric smoke alarm.
KEY FEATURES
HANS-FAC Fire Alarm Controller is listed in the HANS Industrial IoT product catalog as a fire alarm controller under Safety & Smart Infrastructure Monitoring. Measurement range: One addressable loop; available system capacities 64, 128 or 248 points (variant-dependent). Power supply: Mains AC220V (+10%, -15%), 50Hz ±5%, 1A; backup DC12V sealed maintenance-free battery.
PRODUCT SYSTEM