Water & Wastewater
Water and Wastewater Monitoring
HANS offers reference selections for water-treatment quality sensing, tank/level monitoring, pump condition monitoring and telemetry. Documented sensor types include pH, conductivity, dissolved oxygen, residual chlorine, COD, level and pressure transmitters.
Applications
Raw-water intake and treatment monitoring; distribution-network quality measurement; reservoir and tank level sensing; pump vibration and temperature; remote utility-site reporting.
Engineering and Integration
Check the water chemistry, operating pressure and temperature, wetted materials, cleaning/calibration intervals, supply voltage and RS-485 Modbus register definitions per model. For example, PH03 and EC05 use dedicated sensor-specific calibration and communication instructions; protocols are not interchangeable.
FAQ
Are probes maintenance-free? No. Cleaning and calibration requirements depend on sensor technology and water conditions.
Can all sensors use a single calibration procedure? No. Follow the exact manufacturer manual for each device.

INDUSTRY OVERVIEW
Industrial water and wastewater monitoring with pH, EC, dissolved oxygen, COD, residual chlorine, level, pressure and remote telemetry reference products.
KEY CHALLENGES
- Water chemistry, suspended solids and process conditions affect sensor selection, wetted materials and measurement stability.
- pH, conductivity, dissolved oxygen, COD, residual chlorine and turbidity instruments have different calibration, cleaning and maintenance requirements.
- Level measurement and water-quality measurement are separate functions and should not be represented by the same sensor category.
- Remote treatment sites need suitable power, communication coverage and a verified path from field instruments to the monitoring platform.
RECOMMENDED SOLUTIONS
- Select the water-quality parameter and exact sensor model according to the process range, wetted materials, installation point and maintenance plan.
- Follow the individual manufacturer manual for calibration, cleaning, warm-up, reagent or probe replacement requirements; do not apply one procedure to every sensor.
- For digital devices, verify the exact RS-485/Modbus register map, address, baud rate and data format before connecting to an acquisition terminal.
- Add level, pressure or pump-condition monitoring only where the application requires those separate measurements; choose remote telemetry by site coverage and power availability.
KEY BENEFITS
- Support continuous observation of selected water-quality and process parameters.
- Provide traceable measurements for treatment operations and maintenance review.
- Help identify changes in water conditions between manual sampling intervals when the selected sensor supports the required measurement.
- Combine quality, level and equipment monitoring as separate, compatible parts of a project architecture.