HANS-RL03 80 GHz FMCW Radar Level Transmitter
The HANS-RL03 is a 76–81 GHz FMCW non-contact radar level transmitter for liquids, powders and granular solids. It measures the distance to the material surface and calculates level from vessel geometry. Manufacturer-stated performance is up to 120 m range, ±1 mm accuracy and a 0.1 m blind zone. Available electrical variants include two-wire 4–20 mA with HART and four-wire RS485 Modbus RTU. The instrument offers local LCD/keypad operation, echo-curve diagnostics and false-echo learning. Typical applications include chemical reactors, cement and coal silos, wastewater tanks, and vessels with vapor, foam or crystallizing media. Confirm antenna, process limits and hazardous-area certification for the exact ordered configuration.


PRODUCT TYPE
FMCW Radar Level Transmitter
TECHNOLOGY
76–81 GHz FMCW (frequency-modulated continuous-wave) radar
TECHNICAL DATA
HANS-RL03 80 GHz FMCW Radar Level Transmitter
Non-contact level measurement for liquids, powders and granular solids. The radar is installed above the vessel and calculates the distance to the material surface from the frequency difference between transmitted and received FMCW signals. Vessel height is used to derive the level.
Measurement
- Operating frequency: 76–81 GHz
- Maximum measuring range: 120 m
- Accuracy: ±1 mm (manufacturer-stated; confirm conditions and range limits for the selected antenna)
- Blind zone: 0.1 m
- Beam angle: 3° lens antenna as specified on the product page
Electrical and communications
- Supply: DC 24 V ±6 V
- Two-wire version: 4–20 mA with HART
- Four-wire version: RS485 with Modbus RTU
- Configurable fault current: 3.6 mA, 21 mA or hold-current mode
- Use the wiring and interface variant ordered; the outputs are not assumed to be simultaneously available on every unit
Process and environmental limits
- Process pressure: −1 to 20 bar
- Process temperature: −40 to +200 °C (confirm antenna/configuration limits)
- Storage temperature: −40 to +80 °C
- Ingress protection: IP67
- Relative humidity: below 95% RH, non-condensing
- Vibration resistance: 10 m/s² at 10–150 Hz
- Housing: cast aluminum or stainless steel
Process connection and antenna options
- G1-1/2 threaded connection
- Flanged connections from DN50
- Standard lens, adjustable universal horn/lens and high-temperature adjustable lens options are described by the manufacturer; confirm the selected antenna and nozzle limits before ordering
Display, configuration and diagnostics
Local LCD and keypad (ESC, +, arrow and OK). The interface can display level, output current and housing temperature; view echo and history curves; perform false-echo learning; adjust gain, damping, echo mode, measurement range and distance/zero offsets; configure current output and fault current; back up and restore parameters; and perform local firmware upgrades.
Installation guidance
- Keep the instrument at least 200 mm from the vessel wall; the source recommends a position around one-sixth of vessel diameter.
- Avoid the vessel center and the direct path above the filling inlet.
- Keep the beam clear of internal supports, welds and other fixed obstructions; use an adjustable antenna where alignment is required.
- Do not exceed the permitted nozzle height for the selected antenna. The source recommends large-aperture lens options for DN80 and larger flanges.
- For two-wire wiring, use a shielded two-core cable; for RS485, use shielded twisted pair. Seal unused M20 × 1.5 cable entries and form a drip loop.
- In hazardous areas, installation, barriers and wiring must follow the applicable certificate and local hazardous-area requirements.
- After installation, inspect the echo curve, learn fixed false echoes where appropriate, set damping and calibrate the 4–20 mA level span.
Typical applications
Cement, coal powder, lime and mineral silos; chemical reactors and mixing tanks; wastewater storage and equalization tanks; tanks with vapor, foam, boiling or crystallizing media; and high-temperature process vessels. Suitability must be confirmed for the actual dielectric properties, vessel geometry, antenna and process conditions.
Hazardous-area designation: The source page states “ExdiaIICT6”. Verify the complete marking and certificate for the supplied configuration before specifying equipment for a hazardous area.
SPECIFICATIONS
HANS-RL03 80 GHz FMCW Radar Level Transmitter
Non-contact level measurement for liquids, powders and granular solids. The radar is installed above the vessel and calculates the distance to the material surface from the frequency difference between transmitted and received FMCW signals. Vessel height is used to derive the level.
Measurement
- Operating frequency: 76–81 GHz
- Maximum measuring range: 120 m
- Accuracy: ±1 mm (manufacturer-stated; confirm conditions and range limits for the selected antenna)
- Blind zone: 0.1 m
- Beam angle: 3° lens antenna as specified on the product page
Electrical and communications
- Supply: DC 24 V ±6 V
- Two-wire version: 4–20 mA with HART
- Four-wire version: RS485 with Modbus RTU
- Configurable fault current: 3.6 mA, 21 mA or hold-current mode
- Use the wiring and interface variant ordered; the outputs are not assumed to be simultaneously available on every unit
Process and environmental limits
- Process pressure: −1 to 20 bar
- Process temperature: −40 to +200 °C (confirm antenna/configuration limits)
- Storage temperature: −40 to +80 °C
- Ingress protection: IP67
- Relative humidity: below 95% RH, non-condensing
- Vibration resistance: 10 m/s² at 10–150 Hz
- Housing: cast aluminum or stainless steel
Process connection and antenna options
- G1-1/2 threaded connection
- Flanged connections from DN50
- Standard lens, adjustable universal horn/lens and high-temperature adjustable lens options are described by the manufacturer; confirm the selected antenna and nozzle limits before ordering
Display, configuration and diagnostics
Local LCD and keypad (ESC, +, arrow and OK). The interface can display level, output current and housing temperature; view echo and history curves; perform false-echo learning; adjust gain, damping, echo mode, measurement range and distance/zero offsets; configure current output and fault current; back up and restore parameters; and perform local firmware upgrades.
Installation guidance
- Keep the instrument at least 200 mm from the vessel wall; the source recommends a position around one-sixth of vessel diameter.
- Avoid the vessel center and the direct path above the filling inlet.
- Keep the beam clear of internal supports, welds and other fixed obstructions; use an adjustable antenna where alignment is required.
- Do not exceed the permitted nozzle height for the selected antenna. The source recommends large-aperture lens options for DN80 and larger flanges.
- For two-wire wiring, use a shielded two-core cable; for RS485, use shielded twisted pair. Seal unused M20 × 1.5 cable entries and form a drip loop.
- In hazardous areas, installation, barriers and wiring must follow the applicable certificate and local hazardous-area requirements.
- After installation, inspect the echo curve, learn fixed false echoes where appropriate, set damping and calibrate the 4–20 mA level span.
Typical applications
Cement, coal powder, lime and mineral silos; chemical reactors and mixing tanks; wastewater storage and equalization tanks; tanks with vapor, foam, boiling or crystallizing media; and high-temperature process vessels. Suitability must be confirmed for the actual dielectric properties, vessel geometry, antenna and process conditions.
Hazardous-area designation: The source page states “ExdiaIICT6”. Verify the complete marking and certificate for the supplied configuration before specifying equipment for a hazardous area.
KEY FEATURES
- 76–81 GHz FMCW radar for non-contact liquid and bulk-solid level measurement.
- Manufacturer-stated ±1 mm accuracy, up to 120 m range and 0.1 m blind zone.
- Narrow-beam 3° lens antenna option to reduce interference from fixed vessel structures.
- Two-wire 4–20 mA/HART or four-wire RS485/Modbus RTU hardware variants.
- Local LCD/keypad, echo-curve display and false-echo learning for commissioning.
- Configurable damping, gain, echo mode, distance offsets and current-output fault behavior.
- IP67 housing in cast aluminum or stainless steel; process limits depend on antenna and configuration.
- Threaded, flanged and adjustable mounting options.
PRODUCT SYSTEM