Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

FX01
Industrial IoT
Weather Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
FX01
Model: HANS-FX01 V1.1 wind-direction sensor.
Measurement: Direction 0–360°; accuracy ±1°; resolution 0.1°; starting wind speed ≤0.5m/s; maximum rotation radius 100mm.
Supply/output variants: DC5–24V for 0–2V or RS485; DC12–24V for 0–5V, 0–10V or 4–20mA. Select one output: 0–2V, 0–5V, 0–10V, 4–20mA or RS485 Modbus RTU. Analog output and RS485 wiring/output configurations are alternatives.
Environment/protection: Operating temperature -30 to +70°C; humidity ≤100% RH; IP65. Aluminum housing with weather-resistant, corrosion-resistant and waterproof construction.
Communications: RS485 Modbus RTU; 8 data bits, no parity, 1 stop bit, CRC; baud 1200/2400/4800/9600/57600/115200bps, default 9600; device address default 1. Read registers return wind direction angle and 16-point compass direction; angle is raw value divided by 10, direction code 0x00–0x0F.
Direction mapping: The manual provides 16 sectors: N, NNE, NE, ENE, E, ESE, SE, SSE, S, SSW, SW, WSW, W, WNW, NW and NNW, with analog voltage/current thresholds and RS485 codes.
Configuration boundary: Output type and matching supply voltage must be selected together. Do not transfer FS01 wind-speed measurement values to FX01.

G20-NH3
Industrial IoT
Ammonia Gas Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
G20-NH3
Model: G20-NH3
Specification: G20-NH3 Wireless Ammonia Gas Sensor
Measurement range: 5–500 ppm
Power supply: DC 10–15 V; standard 12 V adapter
Communication: NB-IoT wireless; Modbus-RTU stated in manual

GAH-08A Gas Alarm Control Host
Industrial IoT
Gas Alarm Control Host
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
GAH-08A
Model: HANS-GAH-08A gas alarm control host V1.0, each channel connects to a detector. This is a host/controller, not a sensing probe.
Electrical: The original technical table p.2844 prints two input ranges exactly: 165–264 VAC and 200–370 VAC, without defining the different configurations. Preserve both as an unresolved input-voltage SOURCE_CONFLICT. Rated 2.4W/channel, 0.1A/channel, full-load 1A, total power 24W; backup 18.5–21VDC at 2A. Do not select one input range or merge them.
Interfaces/alarm: 2.8-inch TFT display, two adjustable-level alarms and fault alarm, buzzer/LED. 24VDC 100mA per channel. Detector input RS485 and/or 4–20mA by configuration; upstream RS485; two configurable high/low alarm relays. Relay contact capacities printed 277VAC/10A or 125VAC/12A; selectable level or pulse trigger modes.
Environment: Indoor use, −25…+70°C, 10–95%RH non-condensing, 86–106kPa; storage −20…+50°C, 10–95%RH. Wall-mount four-/eight-channel enclosure 260×215×80mm.
HOLD: Supply input range identity/configuration remains unconfirmed, so do not promote to a verified single power supply. Other channel-count and detector options must be confirmed per order.

HPR05-WF
Industrial IoT
Radar Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HPR05-WF
Model: HANS-HPR05-WF, V1.4 Wi-Fi human-presence radar sensor. Wi-Fi communication; TCP/IP and MQTT. External DC 10–24 V supply; power ≤3 W; ABS housing.
Detection: Moving presence 0–4 m (vertical distance); stationary presence 0–3 m; horizontal angle 90°, vertical angle 60°; motion trigger time less than 0.5 s; distance resolution ≤0.5 m; operating frequency 24 GHz.
Environment and installation: Operating temperature -20 to 70°C; storage temperature -40 to 85°C; operating humidity 0–90% RH; storage humidity 0–95% RH; ceiling-mounted; standard cable 1 m, other lengths by arrangement.
Output: Dual switch outputs, maximum 30 VDC / 1 A. This is the Wi-Fi WF model only; no RS485 HPR05-R4 parameters are inherited.

HPR06-A 60GHz Sleep & Vital-Sign Radar Sensor
Industrial IoT
60GHz Vital-Sign Radar Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HPR06-A
Model: HANS-HPR06-A 60GHz breathing and sleep radar, MQTT manual. The source begins with the HPR06-A title; this is distinct from HPE06-E and other HPR05/HPR06 variants.
Installation/detection envelope (组合1 p.2531): Tilt installation at 45° above the head of the bed; recommended mounting height 0.8–1.2m above the bed. Reference maximums: human presence 2m; bed-entry detection 1m; unoccupied/bed-exit detection 2m; respiration-rate detection 1.5m. Actual detection distance may vary by ±0.5m. The installation drawing shows a 5V/USB power cable.
MQTT topics/protocol (pp.2532–2533): JSON version 1.0. Publish topic /Radar60SP/{device ID}/sys/property/post; command topic /Radar60SP/{device ID}/sys/property/set. Methods include post/get/set; online state and heartbeat are actively reported. initFinish is query-only; productMode and hardwareModel are query-only identifiers (11 bytes); Wi-Fi firmware version is reported at server connection; firmware version is reported on connection.
Presence/motion properties (pp.2536–2541): locationOutOfBounds 0 outside/1 inside; humanSwitch 0/1; someoneExists 0/1; motionStatus 0 none/1 stationary/2 active; movementSigns 0–100; humanDistance 0–65535cm; humanPosition x/y/z each 0–65535. Several properties support get queries; function switches support set commands.
Breathing/heart-rate properties (pp.2541–2545): breathSwitch and heartRateSwitch 0/1; breathInform 1 normal, 2 high, 3 low, 4 detecting; breathValue and heartRateValue source range 0–30 (unit not stated); breathWave and heartRateWave each report five integer values 0–255.
Sleep properties (pp.2545–2554): sleepSwitch 0/1; sleepStatus 0 deep sleep, 1 light sleep, 2 awake, 3 none/off-bed; getIntoBed 0 off-bed/1 in-bed; awakeDuration, lightSleepDuration, deepSleepDuration and sleepScore ranges 0–65536. reportMode 0 real-time data/1 sleep-status transmission. sleepComprehensiveStatus reports eight values: presence, sleep status, average respiration, average heart rate, turning count, large-movement ratio, small-movement ratio and apnea count. sleepQualityAnalysis reports 12 integer bytes including score, 2-byte total sleep duration, awake/light/deep ratios, off-bed duration/count, turns, average respiration/heart rate and apnea count. abnormalSleep: 0 sleep 12h; 2 prolonged abnormal absence; 3 none.
Reporting/QoS/OTA (pp.2554–2558): limit_get/limit_set can suppress frequent property reports; value 1 prohibits reporting, 0 allows. MQTT QoS default 1; supported 0/1/2. OTA module 0 selects Wi-Fi module, 1 selects radar module; OTA info contains firmware URL and port; the customer must host the web server. downloadProgress reports 0–100%.
Interference and application cautions (pp.2559–2561): Thin walls may allow detection through to adjacent rooms; unstable power and moving fans/plants/metal objects/pets/motors/washing machines can cause false positives; metal and thick furniture can block detection. Up to three radars may operate in one area without mutual interference if aimed in the same direction. Fix the radar securely; vibration causes false alarms. Initial stabilization time ≥30s before outputs are considered valid. Radar passes through cotton/clothing; wood, glass, gypsum board and plastic have limited penetration; metal blocks radar.
Configuration boundary: The source does not provide a full electrical rating table, nor explicit units for the 0–30 breath/heart-rate values. Do not invent them. Preserve 5V/USB only as shown in the installation drawing. MQTT examples are protocol data structures, not additional sensor specifications.

HPR06-B 60GHz Human Presence & Fall Detection Radar
Industrial IoT
60GHz Presence & Fall Detection Radar
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HPR06-B
Input: AC 110–220V. Communication: Wi-Fi (up to 100m in open area). Transmit power: ≤10dBm (10mW).
Detection: horizontal 90°, pitch 60°; no-person to person response approximately 0.5s; fall alarm approximately 10s.
Environment: -10 to +55°C, RH ≤95%. Dimensions: Ø80 × 45.5mm; ceiling mounting bore 65–70mm, recommended installation height 2.0–2.75m.
Original source: HANS-HPR06-B V1.0, 组合1 pp.2991–3001; model-specific table p.2994. Specifications are for reference and may require ordered-configuration confirmation.

IGD Explosion-Proof Gas Alarm Detector
Industrial IoT
Explosion-Proof Gas Alarm Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD
Model: HANS-IGD V1.2 explosion-proof gas detector; diffusion sampling; online continuous monitoring.
Electrical: DC 12–30 V; power consumption ≤3 W; response time ≤15 s for the listed sensor modules.
Environment: Operating temperature -10 to +50°C; operating humidity ≤99% RH, non-condensing; ambient pressure 86–106 kPa.
Explosion protection and enclosure: Flameproof construction; Ex d II CT6; IP65/IP66; G1/2 internal thread; wall-mounted; display version 181 × 136 × 93 mm; weight ≤1.5 kg.
Outputs and wiring variants: 4–20 mA, RS485, or PowerBus two-wire according to the ordered configuration. The manual specifies separate cable and terminal arrangements for each; do not combine them as simultaneous outputs. Maximum detector-to-controller distance ≤1000 m. Cable requirements: shielded cable ≥1.5 mm² × 3 for 4–20 mA, ×4 for RS485, ×2 for PowerBus; cable outer diameter 6–9 mm.
Replaceable gas modules: NH3 0–500 ppm, accuracy ≤±3% of reading, response <15 s, resolution 0.1/1 ppm; SO2 0–2000 ppm, ≤±3%, <15 s, 0.1/1 ppm; combustible gas 0–100% LEL, ≤±5%, <15 s, 1% LEL/1% VOL; H2S 0–1000 ppm, ≤±3%, <15 s, 1 ppm; CO 0–2000 ppm, ≤±3%, <15 s, 1 ppm. The flammable-gas module option list includes methane, acetone, ethanol, ethyl acetate, ethylene, hydrogen, isopropanol, methanol, methyl ethyl ketone, n-butane, n-heptane, n-hexane, n-pentane, propane, n-octane, toluene, styrene, organic solvents, CO, acetic acid and unleaded gasoline. The manual describes different replaceable modules; these are not all installed simultaneously.
Service life: Sensor life approximately 2 years in normal clean ambient conditions.
RS485 protocol: Modbus RTU; 8 data bits, no parity, 1 stop bit, CRC; baud rates 600/1200/4800/9600 bps (default 9600); device address default 0x01, configurable 1–239. Function 0x03 reads registers and 0x10 writes settings. Register map and frame examples are in printed manual pp.12–15.
Alarm and operation: Startup self-check and sensor preheat (typically 120 s, dependent on sensor type); low/high alarm thresholds and relay status are configurable. The manual specifies sensor replacement and recalibration procedures.

IGD-KL
Industrial IoT
Gas / Dust Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD-KL
Model: HANS-IGD-KL V1.3 explosion-proof dust detector. Continuous 24-hour online monitoring of combustible and hazardous dust, with audible/visual alarm and standard signal output for PLC/DCS and alarm systems.
Detection: Laser-scattering principle; PM2.5, PM10 and PM1.0; range 0–1000 μg/m³ (expandable); resolution 1 μg/m³. Accuracy: 0–100 μg/m³ ±10 μg/m³; 101–1000 μg/m³ ±10% of reading. Batch data consistency ≥90%.
Electrical and outputs: DC 10–36 V supply; operating current ≤300 mA; RS485 with Modbus RTU; optional 4–20 mA output; one relay, AC250V 5A, normally open.
Environment: Working humidity 0–99% RH, non-condensing; storage temperature -30 to 60°C; storage humidity 0–99% RH, non-condensing. No operating-temperature range or IP rating is stated in the parameter table.
Communications: Modbus RTU; configurable address 1–255, default 1; default baud rate 9600; 8 data bits, 1 stop bit, no parity. Separate RS485 and 4–20mA wiring configurations are documented.
Identity: IGD-KL is taken from the exact manual cover and retained as the canonical model label; no IGD variant is inferred.

IGD-TH Explosion-Proof Temperature & Humidity Detector
Industrial IoT
Explosion-Proof Temperature & Humidity Detector
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IGD-TH
Model: HANS-IGD-TH V1.3 explosion-proof temperature and humidity detector. Continuous measurement for indoor/outdoor and industrial environments.
Measurement: Temperature range -40 to +125°C; humidity range 0–100% RH. Accuracy ±0.5°C within 0–90°C; humidity ±3% RH under 25°C and 1m/s airflow. Resolution 0.1°C and 1% RH.
Electrical/environment: DC 12–30V; power ≤3W; response time ≤15s; operating temperature -40 to +85°C; operating humidity 0–90% RH, non-condensing; ambient pressure 86–106kPa.
Explosion protection and enclosure: Flameproof Ex d II CT6; IP65/IP66; G1/2 internal thread; wall-mounted; display version 181 × 136 × 93mm; weight ≤1.5kg.
Outputs/configurations: 4–20mA temperature output (-40 to +100°C) and 4–20mA humidity output (0–100% RH); RS485; or PowerBus two-wire according to ordered configuration. Separate wiring diagrams are provided for analog, RS485 and PowerBus versions. Relay and audible/visual alarm wiring options are also shown. Do not assume every output is installed simultaneously.
Wiring: Analog version: V power positive, G power negative, S1 temperature output, S2 humidity output. RS485 version: V, G, A=RS485A, B=RS485B. PowerBus uses 24V positive/negative with polarity matching the controller. Product label governs wire colors.
Communications: Modbus RTU; 8 data bits, no parity, 1 stop bit, CRC; baud rates 600/1200/4800/9600bps (default 9600); device address default 0x01. Function 0x03 reads registers; function 0x10 writes settings. Temperature registers include integer and float representations; humidity registers use integer representation with three decimal places; address and baud-rate registers are documented.
Display/menu: Four-digit seven-segment LED; normal/fault/high/low status indications. Menus include low/high alarm thresholds, full scale, zero calibration, temperature/humidity calibration, bus address and optional remote-control handshake.
Configuration boundary: Output type and relay/alarm wiring depend on ordered hardware configuration. The manual distinguishes analog, RS485 and PowerBus variants; do not combine them into a single guaranteed interface set.

IR62 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR62
Model: IR62
Specification: HANS-IR62 Infrared Temperature Sensor RS485 Module
Measurement range: Product variants: 0–200/300/400/500/600/800/1200°C; -20–100/200/300/500/600/1200°C. Shared Modbus register envelope -50…600°C is NOT the calibrated range of every product.
Accuracy: ±2% of reading or ±2°C, whichever is greater
Resolution: Optical resolution 15:1 or 20:1, configuration-dependent
Power supply: 6–32VDC overall; variant/output wiring supply may differ
Communication: RS-485 serial output
Output signal: 0–5V, 0–10V, 4–20mA, RS485 or K-type thermocouple (configuration-dependent)
Operating temperature: 0–60°C
Operating humidity: 10–95% RH, non-condensing
IP rating: IP65

IR62S-69 Online Infrared Temperature Sensor
Industrial IoT
Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR62S-69
Model: IR62S-69
Specification: HANS-IR62S-69 Online Infrared Temperature Sensor
Measurement range: Variant-dependent: 0–100°C, 0–200°C, 0–300°C, 0–400°C, 0–500°C; Modbus register envelope −50 to +600°C subject to actual variant limits
Accuracy: ±1% of reading or ±1°C, whichever is greater
Resolution: Optical resolution 15:1
Power supply: 6–28VDC for 4–20mA/RS485; 11–28VDC for 0–5V/0–10V/K-type thermocouple
Output signal: 0–5V, 0–10V, 4–20mA, RS485 or K-type thermocouple (variant-dependent)
Operating temperature: 0 to +60°C
Operating humidity: 10–95% RH, non-condensing

IR65 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
IR65
Model: HANS-IR65 V1.0 online infrared temperature sensor.
Measurement: Variant ranges 0–100/200/300/400/500/600°C; wavelength 8–14μm; emissivity preset 0.95 and software-adjustable. Field of view 8.5°; DS ratio 20:1 and optical resolution 20:1; maximum detection distance 6m. Response 600ms (95%); accuracy ±2% of reading; repeatability ±0.5% of reading.
Electrical/output: DC12–28V; current consumption 2.9–3.3mA; 4–20mA output. Wiring: red DC positive 12–28V, black 4–20mA signal positive, transparent shield. Cable 1.5m standard; other lengths custom.
Construction/environment: Stainless-steel body; IP65; relative humidity 20–80% non-condensing; storage/ambient technical table gives -20 to +85°C. Dimensions 118mm × Ø18mm.
Ambient-temperature source conflict: The technical table on p.2513 states -20…+85°C, while the ambient-condition note on p.2514 states 0…60°C. Preserve both as conflicting source statements; do not normalize. This record remains on HOLD.
Installation/use: M18×1 threaded housing; direct or bracket installation. Ensure optical path is unobstructed and target fills the field of view; keep lens clean and protect from electromagnetic interference. Cooling protection sleeve may be required outside the stated 0…60°C ambient note.

IR80 Online Infrared Temperature Sensor
Industrial IoT
Infrared Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-IR80
Measurement ranges: Selectable variants include 0–100, 0–200, 0–300, 0–500, 0–600, 0–900 and 0–1200°C.
Optical and response: Fixed emissivity 0.95; wavelength 8–14 μm; optical resolution 20:1 or 30:1; response time 300 ms (95%).
Accuracy and repeatability: Accuracy ±2% or ±2°C, whichever is greater; repeatability ±1% or ±1.5°C, whichever is greater.
Electrical and output: Supply 6–32 VDC. Output options include 4–20 mA, 0–5 V, 0–10 V, K-type or RS485, depending on configuration.
RS485 serial settings: 9600 bps, 8 data bits, no parity, 1 stop bit. Read function 0x03; register 0x0004 provides infrared temperature data. Register scaling and usable range must be matched to the selected sensor range.
Mechanical and protection: Stainless-steel body; standard IP65, with selected custom IP68 options. Length variants include 113, 96, 94, 86 or 69 mm × Ø18 mm.
Configuration: Measurement range, optical resolution, output and enclosure options are model-dependent. Confirm the selected configuration and ambient operating limits before ordering.

JSD01
Industrial IoT
Monitoring Station
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
JSD01
Model: JSD01
Specification: JSD01 Flooding Monitoring Station
Measurement range: 80 cm / 160 cm / 240 cm / 320 cm / 400 cm (80 cm sections combinable)
Power supply: AC 220 V mains power
Communication: 4G output; RS-485 (Modbus) device interface
Installation: Wall-mounted
- Page 20