Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

E10 Multi-Parameter Environmental Monitoring Station
Industrial IoT
Multi-Parameter Environmental Monitoring Station
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-E10 V1.4
Measurement channels: Air temperature −40 to +125°C, accuracy ±0.2°C; relative humidity 0–100%, accuracy ±2%; CO2 0–5000 ppm, accuracy ±(50 ppm + 3%); PM2.5 and PM10 0–999 μg/m³, accuracy ±10% FS; atmospheric pressure 30–110 kPa, accuracy ±0.1 kPa; illuminance 0–65535 Lux, accuracy ±7%; noise 30–130 dB, accuracy ±1.5 dB.
Resolution: Temperature 0.1°C; RH 0.1%; CO2 1 ppm; PM2.5/PM10 1 μg/m³; pressure 0.01 kPa; illuminance 1 Lux; noise 0.1 dB.
Power and environment: DC 6–24 V; at 12 V, 70 mA without GPRS and 130 mA with GPRS. Operating temperature −40 to +70°C.
Connectivity: Selectable GPRS/2G or 4G uplink; RS485 interface. Modbus RTU, 8 data bits, no parity, 1 stop bit, CRC; default address 1 and baud rate 9600 bps. Configurable reporting interval and server connection settings.
Installation: Screw-fixed, level installation. Avoid direct sunlight, windows, doors, HVAC outlets, heat-transfer surfaces and strong electrical interference.
Configuration note: The communication register map includes additional soil-moisture, soil-temperature and gas-concentration registers. Confirm the installed sensor modules and channel configuration for each unit before specifying those additional measurements.

E60V2 Indoor Multi-Parameter Air Quality Sensor
Industrial IoT
Gas / Air Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
E60V2-ETH
Model: E60V2-ETH
Specification: HANS-E60V2 Ethernet Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 10/100 Mbps Ethernet, static IP or DHCP
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-WIFI
Model: E60V2-WIFI
Specification: HANS-E60V2 Wi-Fi Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 10–24V
Communication: Wi-Fi 2.4GHz (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-4G
Model: E60V2-4G
Specification: HANS-E60V2 4G Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 4G mobile data (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2
Base unit: Wi-Fi (TCP Client / MQTT); DC 10–24 V; operating current ≤200 mA; operating temperature -10 to 55°C; operating humidity 0–95% RH; 142 × 41 mm; flame-retardant ABS; wall or ceiling mounting.
Selectable sensor modules: Temperature -40 to +130°C, resolution 0.015°C, accuracy ±0.3°C; humidity 0–100% RH, resolution 0.01% RH, accuracy ±3% RH; PM1.0/PM2.5/PM10 0–1000 μg/m³, resolution 1 μg/m³, accuracy ±15 μg/m³; CO₂ 400–5000 ppm, accuracy ±(50 ppm + 5% reading); formaldehyde 0–1.5 mg/m³, accuracy ±10% reading; TVOC 0–10 mg/m³, accuracy ±10% reading.
Additional selectable gas/environment channels: Ozone 0–10 ppm; methane 0–50000 ppm; CO 0–500 ppm; oxygen 0–25%; ammonia 0–500 ppm; hydrogen sulfide 0–100 ppm; atmospheric pressure 300–1100 hPa; illuminance 0–65535 lx; noise 40–120 dB; public-restroom ammonia and H₂S 0–100 ppm; SO₂ and NO₂ 0–20 ppm. These are configuration-dependent options; they are not asserted as simultaneously installed on every unit.

EC05 Online Conductivity & TDS Sensor
Industrial IoT
Conductivity & TDS Water Quality Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
EC05
Model: EC05
Specification: EC05
Measurement range: Conductivity 0–5000 μS/cm; TDS 0–3000 mg/L
Accuracy: ±1.5% of reading; temperature ±0.3°C
Power supply: DC 12–24 V
Communication: RS-485 Modbus RTU
Operating temperature: 0–50°C
IP rating: IP68
Installation: Immersion installation; 3/4 NPT

ET56 Wireless Temperature Acquisition Unit
Industrial IoT
Wireless Temperature Acquisition Unit
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ET56
Model: ET56
Specification: ET56
Measurement range: 433 MHz wireless; ≤60 m in open area
Power supply: DC 5 V (external adapter)
Communication: RS-485 Modbus RTU; 433 MHz wireless reception
Operating temperature: −20 to +65°C
Installation: DIN-rail mounting

ET70 Bus Wireless Temperature Data Acquisition Unit
Industrial IoT
Bus Wireless Temperature Data Acquisition Unit
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ET70
Model: ET70
Specification: HANS-ET70 Bus Wireless Temperature Data Acquisition Unit
Power supply: AC85–265V or DC120–370V
Communication: One or two RS485 Modbus RTU interfaces; one or two 433MHz LoRa receiving antennas optional
Operating temperature: −20 to +70°C
Operating humidity: 5–95%RH non-condensing

ETB05
Industrial IoT
Electrical Equipment Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ETB05
Model: HANS-ETB05 V1.2 strap-type active pipe surface temperature sensor.
Measurement: Pipeline surface temperature range 0–180°C; accuracy ±1°C.
Wireless: 433 MHz; open-environment wireless distance ≤150 m; transmission power 10 dB; data rate 5000 bps.
Power: 3.6 V lithium battery, 1200 mAh; stated battery life greater than 2 years under the source's operating conditions.
Sampling and reporting: Sampling period 30 seconds; upload interval 10 seconds; when temperature changes by more than 0.5°C, upload immediately; 60-day data history.
Physical: Strap length 390 mm; sensor body 36 × 36 × 27 mm; silicone rubber housing; waterproof and dustproof construction.

ETC05
Industrial IoT
Electrical Equipment Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ETC05
Model: ETC05
Specification: HANS-ETC05 Passive CT-Powered Temperature Sensor
Measurement range: Temperature 0–180°C
Accuracy: ±1°C
Power supply: CT energy harvesting; starting primary current ≥3A; no battery rating stated
Communication: 433MHz wireless, ≤150m unobstructed

ETC06
Industrial IoT
Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
ETC06
Model: ETC06
Specification: ETC06 Online-Powered Wireless Temperature Sensor
Measurement range: 0–180 °C
Power supply: Online-powered; startup current >5 A
Communication: 433 MHz wireless