E60V2 Indoor Multi-Parameter Air Quality Sensor
E60V2 Indoor Multi-Parameter Air Quality Sensor is listed in the HANS Industrial IoT product catalog as a gas / air quality sensor under Industrial Sensors. Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³. Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading. Power supply: DC 12V. Communication: 10/100 Mbps Ethernet, static IP or DHCP. Operating temperature: −10 to +55°C. Reference information only; model configuration and availability are subject to confirmation before ordering.


PRODUCT TYPE
Gas / Air Quality Sensor
TECHNOLOGY
TECHNICAL DATA
E60V2-ETH
Model: E60V2-ETH
Specification: HANS-E60V2 Ethernet Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 10/100 Mbps Ethernet, static IP or DHCP
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-WIFI
Model: E60V2-WIFI
Specification: HANS-E60V2 Wi-Fi Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 10–24V
Communication: Wi-Fi 2.4GHz (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-4G
Model: E60V2-4G
Specification: HANS-E60V2 4G Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 4G mobile data (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2
Base unit: Wi-Fi (TCP Client / MQTT); DC 10–24 V; operating current ≤200 mA; operating temperature -10 to 55°C; operating humidity 0–95% RH; 142 × 41 mm; flame-retardant ABS; wall or ceiling mounting.
Selectable sensor modules: Temperature -40 to +130°C, resolution 0.015°C, accuracy ±0.3°C; humidity 0–100% RH, resolution 0.01% RH, accuracy ±3% RH; PM1.0/PM2.5/PM10 0–1000 μg/m³, resolution 1 μg/m³, accuracy ±15 μg/m³; CO₂ 400–5000 ppm, accuracy ±(50 ppm + 5% reading); formaldehyde 0–1.5 mg/m³, accuracy ±10% reading; TVOC 0–10 mg/m³, accuracy ±10% reading.
Additional selectable gas/environment channels: Ozone 0–10 ppm; methane 0–50000 ppm; CO 0–500 ppm; oxygen 0–25%; ammonia 0–500 ppm; hydrogen sulfide 0–100 ppm; atmospheric pressure 300–1100 hPa; illuminance 0–65535 lx; noise 40–120 dB; public-restroom ammonia and H₂S 0–100 ppm; SO₂ and NO₂ 0–20 ppm. These are configuration-dependent options; they are not asserted as simultaneously installed on every unit.
SPECIFICATIONS
E60V2-ETH
Model: E60V2-ETH
Specification: HANS-E60V2 Ethernet Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 10/100 Mbps Ethernet, static IP or DHCP
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-WIFI
Model: E60V2-WIFI
Specification: HANS-E60V2 Wi-Fi Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 10–24V
Communication: Wi-Fi 2.4GHz (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2-4G
Model: E60V2-4G
Specification: HANS-E60V2 4G Indoor Multi-Parameter Air Quality Sensor
Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³
Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading
Power supply: DC 12V
Communication: 4G mobile data (TCP Client or MQTT)
Operating temperature: −10 to +55°C
Operating humidity: 0–95% RH
Installation: Wall-mounted or ceiling-mounted
E60V2
Base unit: Wi-Fi (TCP Client / MQTT); DC 10–24 V; operating current ≤200 mA; operating temperature -10 to 55°C; operating humidity 0–95% RH; 142 × 41 mm; flame-retardant ABS; wall or ceiling mounting.
Selectable sensor modules: Temperature -40 to +130°C, resolution 0.015°C, accuracy ±0.3°C; humidity 0–100% RH, resolution 0.01% RH, accuracy ±3% RH; PM1.0/PM2.5/PM10 0–1000 μg/m³, resolution 1 μg/m³, accuracy ±15 μg/m³; CO₂ 400–5000 ppm, accuracy ±(50 ppm + 5% reading); formaldehyde 0–1.5 mg/m³, accuracy ±10% reading; TVOC 0–10 mg/m³, accuracy ±10% reading.
Additional selectable gas/environment channels: Ozone 0–10 ppm; methane 0–50000 ppm; CO 0–500 ppm; oxygen 0–25%; ammonia 0–500 ppm; hydrogen sulfide 0–100 ppm; atmospheric pressure 300–1100 hPa; illuminance 0–65535 lx; noise 40–120 dB; public-restroom ammonia and H₂S 0–100 ppm; SO₂ and NO₂ 0–20 ppm. These are configuration-dependent options; they are not asserted as simultaneously installed on every unit.
KEY FEATURES
E60V2 Indoor Multi-Parameter Air Quality Sensor is listed in the HANS Industrial IoT product catalog as a gas / air quality sensor under Industrial Sensors. Measurement range: OPTIONAL SENSOR MODULES ONLY: temperature −40 to +130°C; humidity 0–100%RH; PM1.0/PM2.5/PM10 0–1000µg/m³; CO₂ 400–5000ppm; formaldehyde 0–1.5mg/m³; TVOC 0–10mg/m³. Accuracy: OPTIONAL MODULES: temperature ±0.3°C; humidity ±3%RH; particulate PM channels ±15µg/m³; CO₂ ±(50ppm + 5% reading); formaldehyde ±10% reading; TVOC ±10% reading.
PRODUCT SYSTEM
Available Specifications
HANS E60V2-RS485 RS-485 Multi-Parameter Air Quality Sensor
Model:
E60V2-RS485
Available Specifications
HANS E60V2-RS485-06-CO2 6-in-1 CO2 Air Quality Sensor
Model:
E60V2-RS485-06-CO2
Available Specifications
HANS E60V2-RS485-06-LIGHT 6-in-1 Illuminance Air Quality Sensor
Model:
E60V2-RS485-06-LIGHT
Available Specifications
HANS E60V2-RS485-06-CH2O 6-in-1 Formaldehyde Air Quality Sensor
Model:
E60V2-RS485-06-CH2O