Industrial Products
Explore HANS industrial products engineered for precision, reliability, and demanding applications. Filter by product system, type, technology, bond type, or grit to find the right solution for your requirements.
Products

AVTS-WSS Wireless Three-Axis Vibration & Temperature Sensor
Industrial IoT
Vibration / Condition Monitoring Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-AVTS-WSS
Model: HANS-AVTS-WSS
Specification: HANS-AVTS-WSS
Measurement range: Temperature −30 to 90°C; Z ±70 g (1 Hz–6 kHz ±3 dB); X/Y ±16 g (1 Hz–1300 Hz ±3 dB)
Power supply: Internal non-rechargeable battery 3.6 V, 8500 mAh
Communication: Bluetooth; open area 100 m; obstructed area 20 m
IP rating: IP67

HANS-AVTS-YDS Wired IEPE Vibration and Temperature Sensor
Industrial IoT
Wired IEPE Vibration & Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
Measurement specifications
- Sensing elements: IEPE vibration sensor and temperature sensor.
- Acceleration range: ±70 g.
- Acceleration frequency response: 1 Hz–10 kHz (±3 dB).
- Temperature measurement range: −30 to +90°C.
- Integrated signal conditioning and amplification.
Electrical and system integration
DC 5 V, 0.1 A, maximum 0.5 W, supplied by a compatible edge analytics unit. Wired sensor connection; channel online/offline status can be reported through the acquisition system. Confirm connector pinout, electrical signal format and host compatibility before installation.
Mechanical and environmental specifications
- Metal enclosure, IP67.
- Operating ambient temperature: −40 to +70°C.
- Operating humidity: <90% RH, non-condensing.
- Dimensions: 41.64 × 36.6 × 45.5 mm.
- Net weight: 105 g.
- Mounting thread: 1/4-28 UNF.
- Mounting options: screw fastening, magnetic base or suitable adhesive.
Installation and applications
Mount near the bearing or monitored component on a clean, rigid surface. Select the mounting method according to the required frequency response; rigid screw mounting is preferable for high-frequency measurements. Protect cables from abrasion, heat and moving parts. Suitable for vibration and temperature monitoring of motors, fans, pumps, gearboxes and other industrial machinery. Package information lists one sensor and one product inspection certificate; confirm accessories when ordering.

AVTS-YM Sound, Vibration & Temperature Edge Analytics Unit
Industrial IoT
Sound Vibration & Temperature Edge Analytics Unit
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-AVTS-YM
Model: HANS-AVTS-YM
Specification: HANS-AVTS-YM
Measurement range: Up to 32 kHz sampling; sampling 5/10/30/60 s; interval 30–240 min
Power supply: DC 12 V, 0.8 A; PoE 802.3at Class 4
Communication: 4G; RJ45; RS-485; 8 wired 6-pin input channels

AVTS-YSS Wired Three-Axis IEPE Vibration & Temperature Sensor
Industrial IoT
Wired Three-Axis IEPE Vibration & Temperature Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-AVTS-YSS
Model: HANS-AVTS-YSS
Specification: HANS-AVTS-YSS
Measurement range: Temperature −30 to 90°C; Z ±70 g (1 Hz–10 kHz ±3 dB); X/Y ±16 g (1 Hz–1500 Hz ±3 dB)
Power supply: DC 5 V, 0.1 A (from analytics unit)
Communication: Wired to analytics unit
IP rating: IP67

CLS05 Online Residual Chlorine Sensor
Industrial IoT
Water Quality Residual Chlorine Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-CLS05
Model: HANS-CLS05
Specification: HANS-CLS05
Measurement range: HClO: 0–2.000 mg/L; resolution 0.001 mg/L
Accuracy: HClO: ±5% or ±0.05 mg/L; temperature: ±0.3°C
Power supply: DC 12–24 V
Communication: RS-485 (Modbus RTU)
Operating temperature: 5–50°C
IP rating: IP68

CMD02 Air Quality Controller
Industrial IoT
Air Quality Controller
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
CMD02
Exact identity: HANS-CMD02 V1.0 air quality controller, source 组合1 p.2676–2685. Separate from CMD01 monitoring host and CMD03 CO detector.
Electrical and I/O: AC220V 50Hz; standby <3W and actuation <10W; 24V actuator output; three digital inputs, two relay digital outputs; one two-wire bus and one RS485 interface. Max communication distance 1000m. DIN35 rail. Working −20 to +55°C; storage −40 to +70°C; RH≤90% non-condensing; IP30. Manual cites GB16806-2006 (not proof of certificate).
Function: Displays online/alarm/fault detector counts, bus current and fan status. Menu offers detector status, alarm/fault records, fan manual/automatic control, address scan, detector threshold, sounder and alarm enable, offline delay, time and backlight settings.
Protocol reference, independent VA1.05 communication document, 组合1 p.2666–2675: Monitor host ↔ controller via RS485 Modbus RTU, controller ↔ detector via two-wire RTBus4.0. Up to 64 detector nodes per controller. Host-controller serial defaults in protocol: 9600bps, 8N1, controller address 1, configurable 1–32; function 03 reads and 16 writes. Controller-register addresses include 0x601 bus status, 0x622 device address, 0x623 baud, 0x627 controls, 0x629 CO alarm threshold, 0x62E–0x630 detector counts, 0x631–0x632 fan status. Node registers have separate mapped address ranges.

COD05 Online COD Sensor
Industrial IoT
Water Quality COD Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-COD05
Model: HANS-COD05
Specification: HANS-COD05
Measurement range: COD: 0–200 mg/L equivalent KHP with turbidity 0–100 NTU; or COD 0–500 mg/L equivalent KHP with turbidity 0–200 NTU
Accuracy: COD ±5%; turbidity ±5%
Power supply: DC 12–24 V
Communication: RS-485 Modbus RTU
Operating temperature: 0–50°C
IP rating: IP68

CUDM50A
Industrial IoT
Industrial Meter
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
CUDM50A
Model: CUDM50A
Specification: HANS-CUDM50A Three-Phase CT-Type Power Quality Meter
Measurement range: Voltage inputs 100/220/380V selectable; current inputs 5/20/50/100/200/300/400/500A selectable via external CT
Accuracy: Voltage/current/power ±1.0%; active energy class 1
Power supply: DC 12V auxiliary supply; typical power ≤1W
Communication: RS-485
Operating humidity: 5–95% RH, non-condensing at 40°C
Installation: 35mm DIN rail or screw mounting, hole spacing 104×70mm

DA01 Tilt Sensor
Industrial IoT
Tilt Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA01-A1
Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; 4–20 mA output; −40 to +85°C; IP67.
DA01-R4
Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; RS-485 Modbus RTU; −40 to +85°C; IP67.
DA01-V1
Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; 0–5 V analog output; −40 to +85°C; IP67.
DA01-NB
Three-axis X/Y/Z inclination; −90° to +90°; 0.01° resolution; 0.05° static accuracy at 25°C; 3.6 V lithium thionyl chloride battery, 8.5 Ah or 19 Ah; NB-IoT; −20 to +70°C; IP65; 116 × 91 × 60 mm.

DA02 Wireless Tilt Sensor
Industrial IoT
Motion & Position Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA02-4G
Model: DA02-4G
Specification: DA02-4G
Measurement range: X/Y tilt ±90°; temperature −40 to +85°C
Accuracy: Selectable tilt ±0.2°, ±0.05°, ±0.01°
Resolution: 0.01°
Power supply: ER34615 lithium battery DC 3.6 V (19 Ah); optional external DC 12 V, 1 A
Communication: 4G cellular; MQTT uplink
IP rating: IP67
Installation: Horizontal or vertical installation
DA02-LR
Model: DA02-LR
Specification: DA02-LR
Measurement range: X/Y tilt ±90°; temperature −40 to +85°C
Accuracy: Selectable tilt ±0.2°, ±0.05°, ±0.01°
Resolution: 0.01°
Power supply: ER34615 lithium battery DC 3.6 V (19/38 Ah optional); optional external DC 12 V, 1 A
Communication: LoRa (sensor to R10 LoRa gateway)
IP rating: IP67
Installation: Horizontal or vertical installation

DA03 Dynamic Tilt Sensor
Industrial IoT
Dynamic Tilt Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA03
Model: HANS-DA03 V1.0 three-axis dynamic tilt / attitude sensor.
Heading: Relative heading accuracy ≤0.01° RMS; resolution 0.01°; repeatability 0.1°. Pitch: Accuracy 0.01°; range ±85°; resolution 0.01°. Roll: Accuracy 0.01°; range ±180°; resolution 0.01°.
Electrical and interface: Input voltage 5 V; hardware interface RS485; GX12-4P connector; communication speed 115200 bps, customizable; output rate 10 Hz default; startup time <70 ms.
Physical and environment: Dimensions 60 × 45 × 18 mm; weight 180 g; operating temperature -40 to +125°C; optimum performance temperature -40 to +125°C.
Calibration: Six-face accelerometer calibration; each face held vertically downward; each face acquisition must be within 6 minutes and error less than 3° before compensation parameters are calculated. No hard-iron or soft-iron calibration is stated.
Protocol boundary: The source states RS485 and provides register/data definitions. It does not explicitly label the transport as Modbus; no Modbus classification is inferred.

DA04-EC6 Six-Axis Electronic Compass
Industrial IoT
Six-Axis Electronic Compass
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA04-EC6
Model: DA04-EC6
Specification: HANS-DA04-EC6 Six-Axis Electronic Compass
Accuracy: Heading ≤0.5° RMS; pitch 0.1°; roll 0.1°
Resolution: 0.01°
Power supply: 5V DC
Communication: RS-485
Operating temperature: −40 to +85°C; best performance −20 to +65°C

DA04-EC9 Nine-Axis Electronic Compass
Industrial IoT
Nine-Axis Electronic Compass
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA04-EC9
Model: HANS-DA04-EC9 V1.0 nine-axis electronic compass. Measures and outputs azimuth, pitch and roll; uses a three-dimensional geomagnetic compass principle.
Heading/pitch performance: Heading accuracy ≤0.5° RMS; resolution 0.01°; noise 0.05°. Pitch accuracy 0.1°; pitch tilt range ±180°; resolution 0.01°. Hard-iron and soft-iron calibration are supported. The manual does not state complete heading-angle or roll-angle ranges; do not infer them.
Electrical/interface: Input 9–36VDC; startup <50ms. RS485 hardware interface is customizable; communication rate 115200bps customizable; output rate 1–100Hz customizable. Protocol uses the manual's own binary data frames beginning 55 AA and packet-type/length bytes; do not classify it as Modbus RTU.
Mechanical/environment: 101.6 × 38.1mm; weight 116.3g. Operating temperature -40 to +85°C; best performance -20 to +65°C.
Calibration: Gyroscope calibration requires the sensor to remain stationary. Accelerometer calibration uses six orthogonal faces, each within 3° of vertical. Magnetometer calibration is performed with the compass fixed to the carrier and rotated horizontally through one or two full turns at a steady speed, away from magnetic interference.
Installation cautions: Keep away from iron, magnets, motors and other magnetic materials. The manual recommends at least 40cm separation where possible and non-magnetic mounting screws. A stable magnetic environment is required; the device cannot compensate for changing magnetic interference such as varying DC current or moving batteries.

DA05-IMU6 Six-Axis IMU Attitude Sensor
Industrial IoT
Six-Axis IMU Attitude Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA05-IMU6
Heading/yaw: accuracy ≤0.01° RMS; range 360°; resolution 0.01°; noise 0.05°.
Pitch/roll: pitch accuracy 0.01°, range ±85°; roll accuracy 0.01°, range ±180°; attitude resolution 0.001°. Hard-iron and soft-iron calibration are listed as available in the same table; preserve original wording without assuming a separate magnetometer channel.
Electrical: 5V input; startup <70ms; RS485 hardware interface; 115200bps communication speed customizable; output rate 10Hz customizable; connector flange straight-exit 4P; 60×45×18mm; 70g; operating −40…+85°C, optimal −20…+65°C.
Protocol: dedicated 55 AA binary frame, gyro and accelerometer output and attitude data. Do not infer Modbus RTU. No inheritance from DA04-EC6 compass or DA05-IMU9 nine-axis sensor.

DA05-IMU9 Nine-Axis IMU Attitude Sensor
Industrial IoT
Nine-Axis IMU Attitude Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DA05-IMU9
Model: HANS-DA05-IMU9 V1.0 nine-axis attitude sensor using gyroscope, accelerometer and magnetometer with hard-/soft-iron calibration.
Attitude performance: Heading accuracy ≤0.5° RMS; resolution 0.01°; repeatability 0.05°. Pitch accuracy 0.1°, pitch range ±90°. Roll accuracy 0.1°, roll range ±180°. The manual does not separately state a full heading output range.
Electrical/interface: DC12–24V; startup <70ms. Selectable RS232/TTL/RS485 hardware interface; 115200bps customizable; output rate 1–200Hz customizable. Connector M1. Size 101.6 × 38.1 × 25mm; weight 120g.
Environment: Operating temperature -40 to +125°C; best performance -30 to +65°C.
Communications: Proprietary binary frame protocol with 55 AA header and packet type/length fields. Output includes roll, pitch, yaw, accelerometer X/Y/Z, magnetometer X/Y/Z and gyroscope X/Y/Z. The manual does not describe Modbus RTU; do not classify as Modbus.
Calibration: Gyroscope calibration requires stationary sampling. Accelerometer calibration uses six faces, each within 3° of vertical. Magnetometer calibration rotates the sensor around Z, Y and X axes in a low-interference magnetic environment.
Configuration boundary: Interface, baud rate and output frequency are customizable. Keep the DA05-IMU9 attitude ranges and power separate from DA04-EC9 compass parameters.

DO05 Online Fluorescence Dissolved Oxygen Sensor
Industrial IoT
Water Quality Dissolved Oxygen Sensor
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
DO05
Model: DO05
Specification: DO05
Measurement range: Dissolved oxygen 0–20.00 mg/L (0–200% saturation at 25°C)
Accuracy: ±2%; temperature ±0.3°C
Resolution: 0.01 mg/L; 0.1°C
Power supply: DC 12–24 V
Communication: RS-485 Modbus RTU
Operating temperature: 0–50°C
IP rating: IP68
Installation: Immersion installation; 3/4 NPT

E10 Multi-Parameter Environmental Monitoring Station
Industrial IoT
Multi-Parameter Environmental Monitoring Station
Technology · Bond Type · Grit
GRIT / MESH
BOND TYPE
TECHNOLOGY
SPECIFICATIONS
HANS-E10 V1.4
Measurement channels: Air temperature −40 to +125°C, accuracy ±0.2°C; relative humidity 0–100%, accuracy ±2%; CO2 0–5000 ppm, accuracy ±(50 ppm + 3%); PM2.5 and PM10 0–999 μg/m³, accuracy ±10% FS; atmospheric pressure 30–110 kPa, accuracy ±0.1 kPa; illuminance 0–65535 Lux, accuracy ±7%; noise 30–130 dB, accuracy ±1.5 dB.
Resolution: Temperature 0.1°C; RH 0.1%; CO2 1 ppm; PM2.5/PM10 1 μg/m³; pressure 0.01 kPa; illuminance 1 Lux; noise 0.1 dB.
Power and environment: DC 6–24 V; at 12 V, 70 mA without GPRS and 130 mA with GPRS. Operating temperature −40 to +70°C.
Connectivity: Selectable GPRS/2G or 4G uplink; RS485 interface. Modbus RTU, 8 data bits, no parity, 1 stop bit, CRC; default address 1 and baud rate 9600 bps. Configurable reporting interval and server connection settings.
Installation: Screw-fixed, level installation. Avoid direct sunlight, windows, doors, HVAC outlets, heat-transfer surfaces and strong electrical interference.
Configuration note: The communication register map includes additional soil-moisture, soil-temperature and gas-concentration registers. Confirm the installed sensor modules and channel configuration for each unit before specifying those additional measurements.
- Page 15