HANS-AVTS-WSS

Model: HANS-AVTS-WSS

Specification: HANS-AVTS-WSS

Measurement range: Temperature −30 to 90°C; Z ±70 g (1 Hz–6 kHz ±3 dB); X/Y ±16 g (1 Hz–1300 Hz ±3 dB)

Power supply: Internal non-rechargeable battery 3.6 V, 8500 mAh

Communication: Bluetooth; open area 100 m; obstructed area 20 m

IP rating: IP67

View Product →
HANS AVTS-YDS wired IEPE vibration and temperature sensor — original manufacturer image

HANS-AVTS-YDS Wired IEPE Vibration and Temperature Sensor

Industrial IoT

Wired IEPE Vibration & Temperature Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

Measurement specifications

  • Sensing elements: IEPE vibration sensor and temperature sensor.
  • Acceleration range: ±70 g.
  • Acceleration frequency response: 1 Hz–10 kHz (±3 dB).
  • Temperature measurement range: −30 to +90°C.
  • Integrated signal conditioning and amplification.

Electrical and system integration

DC 5 V, 0.1 A, maximum 0.5 W, supplied by a compatible edge analytics unit. Wired sensor connection; channel online/offline status can be reported through the acquisition system. Confirm connector pinout, electrical signal format and host compatibility before installation.

Mechanical and environmental specifications

  • Metal enclosure, IP67.
  • Operating ambient temperature: −40 to +70°C.
  • Operating humidity: <90% RH, non-condensing.
  • Dimensions: 41.64 × 36.6 × 45.5 mm.
  • Net weight: 105 g.
  • Mounting thread: 1/4-28 UNF.
  • Mounting options: screw fastening, magnetic base or suitable adhesive.

Installation and applications

Mount near the bearing or monitored component on a clean, rigid surface. Select the mounting method according to the required frequency response; rigid screw mounting is preferable for high-frequency measurements. Protect cables from abrasion, heat and moving parts. Suitable for vibration and temperature monitoring of motors, fans, pumps, gearboxes and other industrial machinery. Package information lists one sensor and one product inspection certificate; confirm accessories when ordering.

View Product →
HANS Sound Vibration & Temperature Edge Analytics Unit — AI-generated category illustration; not an exact model photograph

AVTS-YM Sound, Vibration & Temperature Edge Analytics Unit

Industrial IoT

Sound Vibration & Temperature Edge Analytics Unit

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-AVTS-YM

Model: HANS-AVTS-YM

Specification: HANS-AVTS-YM

Measurement range: Up to 32 kHz sampling; sampling 5/10/30/60 s; interval 30–240 min

Power supply: DC 12 V, 0.8 A; PoE 802.3at Class 4

Communication: 4G; RJ45; RS-485; 8 wired 6-pin input channels

View Product →
HANS AVTS-YSS wired three-axis IEPE vibration and temperature sensor — original model manual illustration

AVTS-YSS Wired Three-Axis IEPE Vibration & Temperature Sensor

Industrial IoT

Wired Three-Axis IEPE Vibration & Temperature Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-AVTS-YSS

Model: HANS-AVTS-YSS

Specification: HANS-AVTS-YSS

Measurement range: Temperature −30 to 90°C; Z ±70 g (1 Hz–10 kHz ±3 dB); X/Y ±16 g (1 Hz–1500 Hz ±3 dB)

Power supply: DC 5 V, 0.1 A (from analytics unit)

Communication: Wired to analytics unit

IP rating: IP67

View Product →
CLS03 Online Residual Chlorine Sensor

CLS03 Online Residual Chlorine Sensor

Industrial IoT

Water Quality Residual Chlorine Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

View Product →
HANS Water Quality Residual Chlorine Sensor — representative product category image

CLS05 Online Residual Chlorine Sensor

Industrial IoT

Water Quality Residual Chlorine Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-CLS05

Model: HANS-CLS05

Specification: HANS-CLS05

Measurement range: HClO: 0–2.000 mg/L; resolution 0.001 mg/L

Accuracy: HClO: ±5% or ±0.05 mg/L; temperature: ±0.3°C

Power supply: DC 12–24 V

Communication: RS-485 (Modbus RTU)

Operating temperature: 5–50°C

IP rating: IP68

View Product →

CMD02 Air Quality Controller

Industrial IoT

Air Quality Controller

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

CMD02

Exact identity: HANS-CMD02 V1.0 air quality controller, source 组合1 p.2676–2685. Separate from CMD01 monitoring host and CMD03 CO detector.

Electrical and I/O: AC220V 50Hz; standby <3W and actuation <10W; 24V actuator output; three digital inputs, two relay digital outputs; one two-wire bus and one RS485 interface. Max communication distance 1000m. DIN35 rail. Working −20 to +55°C; storage −40 to +70°C; RH≤90% non-condensing; IP30. Manual cites GB16806-2006 (not proof of certificate).

Function: Displays online/alarm/fault detector counts, bus current and fan status. Menu offers detector status, alarm/fault records, fan manual/automatic control, address scan, detector threshold, sounder and alarm enable, offline delay, time and backlight settings.

Protocol reference, independent VA1.05 communication document, 组合1 p.2666–2675: Monitor host ↔ controller via RS485 Modbus RTU, controller ↔ detector via two-wire RTBus4.0. Up to 64 detector nodes per controller. Host-controller serial defaults in protocol: 9600bps, 8N1, controller address 1, configurable 1–32; function 03 reads and 16 writes. Controller-register addresses include 0x601 bus status, 0x622 device address, 0x623 baud, 0x627 controls, 0x629 CO alarm threshold, 0x62E–0x630 detector counts, 0x631–0x632 fan status. Node registers have separate mapped address ranges.

View Product →

CMLY Visual IoT Data Overlay Unit

Industrial IoT

Visual IoT Data Overlay Unit

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-CMLY

View Product →
COD03 Online COD Sensor

COD03 Online COD Sensor

Industrial IoT

Water Quality COD Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

View Product →
HANS Water Quality COD Sensor — representative product category image

COD05 Online COD Sensor

Industrial IoT

Water Quality COD Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-COD05

Model: HANS-COD05

Specification: HANS-COD05

Measurement range: COD: 0–200 mg/L equivalent KHP with turbidity 0–100 NTU; or COD 0–500 mg/L equivalent KHP with turbidity 0–200 NTU

Accuracy: COD ±5%; turbidity ±5%

Power supply: DC 12–24 V

Communication: RS-485 Modbus RTU

Operating temperature: 0–50°C

IP rating: IP68

View Product →

CUDM50A

Industrial IoT

Industrial Meter

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

CUDM50A

Model: CUDM50A

Specification: HANS-CUDM50A Three-Phase CT-Type Power Quality Meter

Measurement range: Voltage inputs 100/220/380V selectable; current inputs 5/20/50/100/200/300/400/500A selectable via external CT

Accuracy: Voltage/current/power ±1.0%; active energy class 1

Power supply: DC 12V auxiliary supply; typical power ≤1W

Communication: RS-485

Operating humidity: 5–95% RH, non-condensing at 40°C

Installation: 35mm DIN rail or screw mounting, hole spacing 104×70mm

View Product →
DA01 — Reference illustration from product documentation. Verify the exact model, variant, interface and mechanical configuration against the original manufacturer manual before ordering.

DA01 Tilt Sensor

Industrial IoT

Tilt Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA01-A1

Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; 4–20 mA output; −40 to +85°C; IP67.

DA01-R4

Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; RS-485 Modbus RTU; −40 to +85°C; IP67.

DA01-V1

Dual-axis X/Y inclination; ±90° range; selectable accuracy ±0.01°, ±0.05° or ±0.2° at 25°C; 0.01° resolution; DC 9–36 V; 0–5 V analog output; −40 to +85°C; IP67.

DA01-NB

Three-axis X/Y/Z inclination; −90° to +90°; 0.01° resolution; 0.05° static accuracy at 25°C; 3.6 V lithium thionyl chloride battery, 8.5 Ah or 19 Ah; NB-IoT; −20 to +70°C; IP65; 116 × 91 × 60 mm.

View Product →
HANS DA02 tilt sensor — original model-specific product image

DA02 Wireless Tilt Sensor

Industrial IoT

Motion & Position Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA02-4G

Model: DA02-4G

Specification: DA02-4G

Measurement range: X/Y tilt ±90°; temperature −40 to +85°C

Accuracy: Selectable tilt ±0.2°, ±0.05°, ±0.01°

Resolution: 0.01°

Power supply: ER34615 lithium battery DC 3.6 V (19 Ah); optional external DC 12 V, 1 A

Communication: 4G cellular; MQTT uplink

IP rating: IP67

Installation: Horizontal or vertical installation

DA02-LR

Model: DA02-LR

Specification: DA02-LR

Measurement range: X/Y tilt ±90°; temperature −40 to +85°C

Accuracy: Selectable tilt ±0.2°, ±0.05°, ±0.01°

Resolution: 0.01°

Power supply: ER34615 lithium battery DC 3.6 V (19/38 Ah optional); optional external DC 12 V, 1 A

Communication: LoRa (sensor to R10 LoRa gateway)

IP rating: IP67

Installation: Horizontal or vertical installation

View Product →
HANS DA03 tilt sensor — original model-specific product image

DA03 Dynamic Tilt Sensor

Industrial IoT

Dynamic Tilt Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA03

Model: HANS-DA03 V1.0 three-axis dynamic tilt / attitude sensor.

Heading: Relative heading accuracy ≤0.01° RMS; resolution 0.01°; repeatability 0.1°. Pitch: Accuracy 0.01°; range ±85°; resolution 0.01°. Roll: Accuracy 0.01°; range ±180°; resolution 0.01°.

Electrical and interface: Input voltage 5 V; hardware interface RS485; GX12-4P connector; communication speed 115200 bps, customizable; output rate 10 Hz default; startup time <70 ms.

Physical and environment: Dimensions 60 × 45 × 18 mm; weight 180 g; operating temperature -40 to +125°C; optimum performance temperature -40 to +125°C.

Calibration: Six-face accelerometer calibration; each face held vertically downward; each face acquisition must be within 6 minutes and error less than 3° before compensation parameters are calculated. No hard-iron or soft-iron calibration is stated.

Protocol boundary: The source states RS485 and provides register/data definitions. It does not explicitly label the transport as Modbus; no Modbus classification is inferred.

View Product →

DA04-EC6 Six-Axis Electronic Compass

Industrial IoT

Six-Axis Electronic Compass

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA04-EC6

Model: DA04-EC6

Specification: HANS-DA04-EC6 Six-Axis Electronic Compass

Accuracy: Heading ≤0.5° RMS; pitch 0.1°; roll 0.1°

Resolution: 0.01°

Power supply: 5V DC

Communication: RS-485

Operating temperature: −40 to +85°C; best performance −20 to +65°C

View Product →

DA04-EC9 Nine-Axis Electronic Compass

Industrial IoT

Nine-Axis Electronic Compass

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA04-EC9

Model: HANS-DA04-EC9 V1.0 nine-axis electronic compass. Measures and outputs azimuth, pitch and roll; uses a three-dimensional geomagnetic compass principle.

Heading/pitch performance: Heading accuracy ≤0.5° RMS; resolution 0.01°; noise 0.05°. Pitch accuracy 0.1°; pitch tilt range ±180°; resolution 0.01°. Hard-iron and soft-iron calibration are supported. The manual does not state complete heading-angle or roll-angle ranges; do not infer them.

Electrical/interface: Input 9–36VDC; startup <50ms. RS485 hardware interface is customizable; communication rate 115200bps customizable; output rate 1–100Hz customizable. Protocol uses the manual's own binary data frames beginning 55 AA and packet-type/length bytes; do not classify it as Modbus RTU.

Mechanical/environment: 101.6 × 38.1mm; weight 116.3g. Operating temperature -40 to +85°C; best performance -20 to +65°C.

Calibration: Gyroscope calibration requires the sensor to remain stationary. Accelerometer calibration uses six orthogonal faces, each within 3° of vertical. Magnetometer calibration is performed with the compass fixed to the carrier and rotated horizontally through one or two full turns at a steady speed, away from magnetic interference.

Installation cautions: Keep away from iron, magnets, motors and other magnetic materials. The manual recommends at least 40cm separation where possible and non-magnetic mounting screws. A stable magnetic environment is required; the device cannot compensate for changing magnetic interference such as varying DC current or moving batteries.

View Product →

DA05-IMU6 Six-Axis IMU Attitude Sensor

Industrial IoT

Six-Axis IMU Attitude Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA05-IMU6

Heading/yaw: accuracy ≤0.01° RMS; range 360°; resolution 0.01°; noise 0.05°.

Pitch/roll: pitch accuracy 0.01°, range ±85°; roll accuracy 0.01°, range ±180°; attitude resolution 0.001°. Hard-iron and soft-iron calibration are listed as available in the same table; preserve original wording without assuming a separate magnetometer channel.

Electrical: 5V input; startup <70ms; RS485 hardware interface; 115200bps communication speed customizable; output rate 10Hz customizable; connector flange straight-exit 4P; 60×45×18mm; 70g; operating −40…+85°C, optimal −20…+65°C.

Protocol: dedicated 55 AA binary frame, gyro and accelerometer output and attitude data. Do not infer Modbus RTU. No inheritance from DA04-EC6 compass or DA05-IMU9 nine-axis sensor.

View Product →

DA05-IMU9 Nine-Axis IMU Attitude Sensor

Industrial IoT

Nine-Axis IMU Attitude Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DA05-IMU9

Model: HANS-DA05-IMU9 V1.0 nine-axis attitude sensor using gyroscope, accelerometer and magnetometer with hard-/soft-iron calibration.

Attitude performance: Heading accuracy ≤0.5° RMS; resolution 0.01°; repeatability 0.05°. Pitch accuracy 0.1°, pitch range ±90°. Roll accuracy 0.1°, roll range ±180°. The manual does not separately state a full heading output range.

Electrical/interface: DC12–24V; startup <70ms. Selectable RS232/TTL/RS485 hardware interface; 115200bps customizable; output rate 1–200Hz customizable. Connector M1. Size 101.6 × 38.1 × 25mm; weight 120g.

Environment: Operating temperature -40 to +125°C; best performance -30 to +65°C.

Communications: Proprietary binary frame protocol with 55 AA header and packet type/length fields. Output includes roll, pitch, yaw, accelerometer X/Y/Z, magnetometer X/Y/Z and gyroscope X/Y/Z. The manual does not describe Modbus RTU; do not classify as Modbus.

Calibration: Gyroscope calibration requires stationary sampling. Accelerometer calibration uses six faces, each within 3° of vertical. Magnetometer calibration rotates the sensor around Z, Y and X axes in a low-interference magnetic environment.

Configuration boundary: Interface, baud rate and output frequency are customizable. Keep the DA05-IMU9 attitude ranges and power separate from DA04-EC9 compass parameters.

View Product →

DAQ Multi-Channel IEPE Data Acquisition System

Industrial IoT

Multi-Channel IEPE Data Acquisition System

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DAQ02

DAQ03

DAQ04

View Product →

DAQ01 Two-Channel IEPE Data Acquisition Unit

Industrial IoT

Two-Channel IEPE Data Acquisition Unit

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DAQ01

View Product →
HANS Industrial — Water quality monitoring in a treatment facility (illustrative product-family application scene, not an exact model photograph)

DO03 Online Fluorescence Dissolved Oxygen Sensor

Industrial IoT

Water Quality Dissolved Oxygen Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

View Product →
HANS Industrial — Water quality monitoring in a treatment facility (illustrative product-family application scene, not an exact model photograph)

DO05 Online Fluorescence Dissolved Oxygen Sensor

Industrial IoT

Water Quality Dissolved Oxygen Sensor

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

DO05

Model: DO05

Specification: DO05

Measurement range: Dissolved oxygen 0–20.00 mg/L (0–200% saturation at 25°C)

Accuracy: ±2%; temperature ±0.3°C

Resolution: 0.01 mg/L; 0.1°C

Power supply: DC 12–24 V

Communication: RS-485 Modbus RTU

Operating temperature: 0–50°C

IP rating: IP68

Installation: Immersion installation; 3/4 NPT

View Product →
DPC01-FS particle counting sensor, original device illustration from HANS manufacturer PDF (组合1 p.2729). Reference image; confirm the exact installed configuration.

DPC01-FS

Industrial IoT

Particle Counting Sensor (Fan Version)

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

View Product →
HANS E10 industrial sensor — original model-specific product photo

E10 Multi-Parameter Environmental Monitoring Station

Industrial IoT

Multi-Parameter Environmental Monitoring Station

Technology · Bond Type · Grit

GRIT / MESH

​

BOND TYPE

​

TECHNOLOGY

​

SPECIFICATIONS

HANS-E10 V1.4

Measurement channels: Air temperature −40 to +125°C, accuracy ±0.2°C; relative humidity 0–100%, accuracy ±2%; CO2 0–5000 ppm, accuracy ±(50 ppm + 3%); PM2.5 and PM10 0–999 μg/m³, accuracy ±10% FS; atmospheric pressure 30–110 kPa, accuracy ±0.1 kPa; illuminance 0–65535 Lux, accuracy ±7%; noise 30–130 dB, accuracy ±1.5 dB.

Resolution: Temperature 0.1°C; RH 0.1%; CO2 1 ppm; PM2.5/PM10 1 μg/m³; pressure 0.01 kPa; illuminance 1 Lux; noise 0.1 dB.

Power and environment: DC 6–24 V; at 12 V, 70 mA without GPRS and 130 mA with GPRS. Operating temperature −40 to +70°C.

Connectivity: Selectable GPRS/2G or 4G uplink; RS485 interface. Modbus RTU, 8 data bits, no parity, 1 stop bit, CRC; default address 1 and baud rate 9600 bps. Configurable reporting interval and server connection settings.

Installation: Screw-fixed, level installation. Avoid direct sunlight, windows, doors, HVAC outlets, heat-transfer surfaces and strong electrical interference.