top of page

HANS Industrial IoT Systems

Request a Quote

CMD02 Air Quality Controller

CMD02 is an air-quality controller with one two-wire bus, one RS485 interface, three switch inputs, two relay outputs and 24V actuator output. Source specifications state up to 1000m communication distance, DIN-rail mounting and AC220V supply.

Industrial IoT OEM and ODM engineering for custom sensors, wireless devices and IoT gateways

PRODUCT TYPE

Air Quality Controller

TECHNOLOGY

​

TECHNICAL DATA

Exact identity: HANS-CMD02 V1.0 air quality controller, source 组合1 p.2676–2685. Separate from CMD01 monitoring host and CMD03 CO detector.

Electrical and I/O: AC220V 50Hz; standby <3W and actuation <10W; 24V actuator output; three digital inputs, two relay digital outputs; one two-wire bus and one RS485 interface. Max communication distance 1000m. DIN35 rail. Working −20 to +55°C; storage −40 to +70°C; RH≤90% non-condensing; IP30. Manual cites GB16806-2006 (not proof of certificate).

Function: Displays online/alarm/fault detector counts, bus current and fan status. Menu offers detector status, alarm/fault records, fan manual/automatic control, address scan, detector threshold, sounder and alarm enable, offline delay, time and backlight settings.

Protocol reference, independent VA1.05 communication document, 组合1 p.2666–2675: Monitor host ↔ controller via RS485 Modbus RTU, controller ↔ detector via two-wire RTBus4.0. Up to 64 detector nodes per controller. Host-controller serial defaults in protocol: 9600bps, 8N1, controller address 1, configurable 1–32; function 03 reads and 16 writes. Controller-register addresses include 0x601 bus status, 0x622 device address, 0x623 baud, 0x627 controls, 0x629 CO alarm threshold, 0x62E–0x630 detector counts, 0x631–0x632 fan status. Node registers have separate mapped address ranges.

SPECIFICATIONS

CMD02

Exact identity: HANS-CMD02 V1.0 air quality controller, source 组合1 p.2676–2685. Separate from CMD01 monitoring host and CMD03 CO detector.

Electrical and I/O: AC220V 50Hz; standby <3W and actuation <10W; 24V actuator output; three digital inputs, two relay digital outputs; one two-wire bus and one RS485 interface. Max communication distance 1000m. DIN35 rail. Working −20 to +55°C; storage −40 to +70°C; RH≤90% non-condensing; IP30. Manual cites GB16806-2006 (not proof of certificate).

Function: Displays online/alarm/fault detector counts, bus current and fan status. Menu offers detector status, alarm/fault records, fan manual/automatic control, address scan, detector threshold, sounder and alarm enable, offline delay, time and backlight settings.

Protocol reference, independent VA1.05 communication document, 组合1 p.2666–2675: Monitor host ↔ controller via RS485 Modbus RTU, controller ↔ detector via two-wire RTBus4.0. Up to 64 detector nodes per controller. Host-controller serial defaults in protocol: 9600bps, 8N1, controller address 1, configurable 1–32; function 03 reads and 16 writes. Controller-register addresses include 0x601 bus status, 0x622 device address, 0x623 baud, 0x627 controls, 0x629 CO alarm threshold, 0x62E–0x630 detector counts, 0x631–0x632 fan status. Node registers have separate mapped address ranges.

KEY FEATURES

CMD02 is an air-quality controller with one two-wire bus, one RS485 interface, three switch inputs, two relay outputs and 24V actuator output. Source specifications state up to 1000m communication distance, DIN-rail mounting and AC220V supply.

PRODUCT SYSTEM

Available Specifications

HANS-CMD02 Air Quality Controller

Model:

CMD02

​

View Specifications
bottom of page