HANS-ZTDA01 Dual 4–20 mA Vibration and Temperature Sensor
The HANS-ZTDA01 integrates MEMS vibration velocity and housing temperature measurement in a stainless-steel industrial transmitter. Two independent 4–20 mA analog outputs connect to compatible PLC, DCS and data acquisition analog inputs for machinery condition monitoring. Select a 0–20 mm/s standard or 0–50 mm/s optional vibration range; temperature measurement spans 0–100°C. DC 9–36 V power, IP65 protection and magnetic or threaded mounting support industrial retrofit and permanent installations.


PRODUCT TYPE
Vibration & Temperature Sensor
TECHNOLOGY
TECHNICAL DATA
Measurement specifications
- Vibration velocity: 0–20 mm/s standard, 0–50 mm/s optional; accuracy ±2% at 80 Hz.
- Frequency response: 10–1600 Hz.
- Housing temperature: 0–100°C; accuracy ±0.5°C.
- Two independent 4–20 mA analog channels, shared power and return (three-wire arrangement per channel).
- DC 9–36 V supply.
- Standard cable 1 m; stated maximum 1000 m subject to cable resistance, supply voltage, analog input load and installation conditions.
Mechanical and environmental
304 stainless steel; IP65; nominal overall height 100 mm; M8 × 1.25 mounting thread. Confirm body diameter and clearance against the selected dimensional drawing. Magnetic or rigid threaded mounting. Storage temperature −40 to +85°C; storage humidity 10–90% RH. Confirm operating ambient limits separately.
Wiring and signal conversion
Documented lead colors: red supply positive, black supply negative, white vibration current output, blue temperature current output. Verify actual device label and analog input wiring before energizing; disconnect power before connecting. Use compatible active-output current inputs or appropriate input wiring. For a valid current I in mA, vibration velocity = (I − 4)/16 × selected full-scale velocity (20 or 50 mm/s); temperature = (I − 4)/16 × 100°C. Out-of-range currents require separate fault handling.
Installation and applications
Mount close to a bearing on a flat rigid surface; use magnetic mounting for suitable retrofit sites or threaded mounting for permanent monitoring. Separate signal cables from high-power cables and protect against mechanical damage. Suitable for motors, fans, pumps, compressors and gearboxes. Hazardous-area installations require separately confirmed approval. Package information lists sensor, magnetic base, inspection certificate and packaging; confirm supplied accessories.
SPECIFICATIONS
Measurement specifications
- Vibration velocity: 0–20 mm/s standard, 0–50 mm/s optional; accuracy ±2% at 80 Hz.
- Frequency response: 10–1600 Hz.
- Housing temperature: 0–100°C; accuracy ±0.5°C.
- Two independent 4–20 mA analog channels, shared power and return (three-wire arrangement per channel).
- DC 9–36 V supply.
- Standard cable 1 m; stated maximum 1000 m subject to cable resistance, supply voltage, analog input load and installation conditions.
Mechanical and environmental
304 stainless steel; IP65; nominal overall height 100 mm; M8 × 1.25 mounting thread. Confirm body diameter and clearance against the selected dimensional drawing. Magnetic or rigid threaded mounting. Storage temperature −40 to +85°C; storage humidity 10–90% RH. Confirm operating ambient limits separately.
Wiring and signal conversion
Documented lead colors: red supply positive, black supply negative, white vibration current output, blue temperature current output. Verify actual device label and analog input wiring before energizing; disconnect power before connecting. Use compatible active-output current inputs or appropriate input wiring. For a valid current I in mA, vibration velocity = (I − 4)/16 × selected full-scale velocity (20 or 50 mm/s); temperature = (I − 4)/16 × 100°C. Out-of-range currents require separate fault handling.
Installation and applications
Mount close to a bearing on a flat rigid surface; use magnetic mounting for suitable retrofit sites or threaded mounting for permanent monitoring. Separate signal cables from high-power cables and protect against mechanical damage. Suitable for motors, fans, pumps, compressors and gearboxes. Hazardous-area installations require separately confirmed approval. Package information lists sensor, magnetic base, inspection certificate and packaging; confirm supplied accessories.
KEY FEATURES
- Independent vibration velocity and temperature analog outputs
- 0–20 or 0–50 mm/s vibration range
- 10–1600 Hz frequency response
- 304 stainless steel IP65 enclosure
- DC 9–36 V supply and flexible mounting
PRODUCT SYSTEM