HANS-Z3TDB Square-Housing Three-Axis Vibration and Temperature Sensor
The HANS-Z3TDB series combines three-axis MEMS vibration measurement and internal temperature sensing for rotating machinery condition monitoring. The Z3TDB-05 configuration provides RS-485 Modbus RTU connectivity, DC 9–28 V power and an IP65 metal enclosure with magnetic mounting. Select the required A/B/C/D/E measurement and diagnostic feature configuration for PLC, SCADA or industrial IoT integration.


PRODUCT TYPE
Vibration / Condition Monitoring Sensor
TECHNOLOGY
TECHNICAL DATA
Z3TDB-05 measurement specifications
- X/Y/Z vibration axes. Velocity: 0–200 mm/s, ±1.5%, resolution 0.1 mm/s.
- Acceleration: ±16 g, ±1.5%, resolution 0.01 g.
- Displacement: 0–5000 μm, ±3%, resolution 1 μm.
- Frequency: 10–5000 Hz, ±1.5%, resolution 1 Hz.
- Vibration accuracy reference: 80 Hz, 10 mm/s.
- Internal temperature: −40 to +85°C, ±0.5°C, resolution 0.1°C. Internal PCB temperature is not necessarily process or surface temperature.
- Detection cycle: greater than 300 ms.
- DC 9–28 V; IP65; metal enclosure, 37 × 55 mm base, 37 mm high; magnetic mounting.
Feature selection
A: temperature and velocity. B: A plus acceleration, displacement and frequency. C: B plus spectrum. D: B plus 16 statistical features. E: B plus spectrum and 16 statistical features. Confirm exact ordering configuration and waveform availability.
Serial communication
RS-485, Modbus RTU; 0x03 read holding registers, 0x06 write single register. Configurable device address 1–240, default 1; baud rate 2400–115200 bit/s, default 9600. Address recovery command: FA 03 00 06 00 01 71 80; isolate a single device during recovery to avoid response collisions. Waveform-capable configurations support 10 or 20 kHz sampling and segmented three-axis waveform retrieval; disable waveform acquisition after reading to resume regular measurement.
Installation
Mount securely near the bearing housing on a suitable flat ferromagnetic surface. Disconnect power before wiring; follow the device label for supply polarity and RS-485 A/B. Use shielded twisted pair and appropriate 120 Ω termination at bus ends as required. Assign unique addresses and protect cables from heat and moving parts. Confirm hazardous-area approval separately before deployment.
Applications
Condition monitoring of motors, fans, pumps, gearboxes, compressors and centrifuges; distributed machinery monitoring through PLC, SCADA and industrial IoT gateways.
SPECIFICATIONS
Z3TDB-05 measurement specifications
- X/Y/Z vibration axes. Velocity: 0–200 mm/s, ±1.5%, resolution 0.1 mm/s.
- Acceleration: ±16 g, ±1.5%, resolution 0.01 g.
- Displacement: 0–5000 μm, ±3%, resolution 1 μm.
- Frequency: 10–5000 Hz, ±1.5%, resolution 1 Hz.
- Vibration accuracy reference: 80 Hz, 10 mm/s.
- Internal temperature: −40 to +85°C, ±0.5°C, resolution 0.1°C. Internal PCB temperature is not necessarily process or surface temperature.
- Detection cycle: greater than 300 ms.
- DC 9–28 V; IP65; metal enclosure, 37 × 55 mm base, 37 mm high; magnetic mounting.
Feature selection
A: temperature and velocity. B: A plus acceleration, displacement and frequency. C: B plus spectrum. D: B plus 16 statistical features. E: B plus spectrum and 16 statistical features. Confirm exact ordering configuration and waveform availability.
Serial communication
RS-485, Modbus RTU; 0x03 read holding registers, 0x06 write single register. Configurable device address 1–240, default 1; baud rate 2400–115200 bit/s, default 9600. Address recovery command: FA 03 00 06 00 01 71 80; isolate a single device during recovery to avoid response collisions. Waveform-capable configurations support 10 or 20 kHz sampling and segmented three-axis waveform retrieval; disable waveform acquisition after reading to resume regular measurement.
Installation
Mount securely near the bearing housing on a suitable flat ferromagnetic surface. Disconnect power before wiring; follow the device label for supply polarity and RS-485 A/B. Use shielded twisted pair and appropriate 120 Ω termination at bus ends as required. Assign unique addresses and protect cables from heat and moving parts. Confirm hazardous-area approval separately before deployment.
Applications
Condition monitoring of motors, fans, pumps, gearboxes, compressors and centrifuges; distributed machinery monitoring through PLC, SCADA and industrial IoT gateways.
KEY FEATURES
- Three-axis MEMS vibration and internal temperature monitoring
- RS-485 Modbus RTU
- 10–5000 Hz frequency range for Z3TDB-05
- Configurable address and baud rate
- Selectable waveform, spectrum and statistical features
- IP65 metal enclosure and magnetic mounting
- DC 9–28 V supply
PRODUCT SYSTEM