SL02V1 is a corrosion-resistant wired liquid level transmitter. The technical documentation specifies 0–100 m customizable range, selectable 4–20mA or RS485 output, DC9–28V supply and IP68 protection.

Industrial IoT OEM and ODM engineering for custom sensors, wireless devices and IoT gateways
HANS SL02V1 — original model image from independent technical manual, square canvas

PRODUCT TYPE

Level Transmitter

TECHNOLOGY

​

TECHNICAL DATA

SL02V1 dedicated original manual V1.0, 组合1 p.3569–3578 — anti-corrosion wired liquid-level transmitter, ceramic body/interface, 0–100m configurable level range, water at normal temperature, 2× range overload, default ±0.5%FS accuracy with ±0.2%FS / ±0.1%FS selectable grades, long-term stability ±0.2%FS/year, power DC9–28V, output RS485 or 4–20mA as order-dependent alternatives (not both guaranteed), ambient operation 0–80°C, storage −40–80°C, reported response 5Hz–2.4kHz, IP68. Cable p.3573: 4–20mA red +24V/black negative; RS485 red +24V/black negative/yellow A/blue B. Modbus RTU default 9600 8N1 with reading 03, writing 06; unit, decimal scaling and measured level/pressure register 0x0004, zero 0x0005, full 0x0006, slave address 0x0000 and baud 0x0001. p.3575 uses '压力' wording inside a liquid-level instrument; retain as copied label, not an extra pressure sensor specification. Preserve independent SL02V1 ceramic identity, do not inherit SL01V2 stainless housing.

SPECIFICATIONS

SL02V1

SL02V1 dedicated original manual V1.0, 组合1 p.3569–3578 — anti-corrosion wired liquid-level transmitter, ceramic body/interface, 0–100m configurable level range, water at normal temperature, 2× range overload, default ±0.5%FS accuracy with ±0.2%FS / ±0.1%FS selectable grades, long-term stability ±0.2%FS/year, power DC9–28V, output RS485 or 4–20mA as order-dependent alternatives (not both guaranteed), ambient operation 0–80°C, storage −40–80°C, reported response 5Hz–2.4kHz, IP68. Cable p.3573: 4–20mA red +24V/black negative; RS485 red +24V/black negative/yellow A/blue B. Modbus RTU default 9600 8N1 with reading 03, writing 06; unit, decimal scaling and measured level/pressure register 0x0004, zero 0x0005, full 0x0006, slave address 0x0000 and baud 0x0001. p.3575 uses '压力' wording inside a liquid-level instrument; retain as copied label, not an extra pressure sensor specification. Preserve independent SL02V1 ceramic identity, do not inherit SL01V2 stainless housing.

KEY FEATURES