HANS-SFO01 SF6 & O2 Sensor
HANS-SFO01 is a combined SF6 and oxygen gas sensor for monitoring sulfur-hexafluoride leakage and oxygen concentration. The documented SF6 measurement method uses non-dispersive infrared technology. Confirm the exact measurement ranges, alarm outputs, communication interface and installation requirements for the selected configuration.


PRODUCT TYPE
SF6 & O2 Gas Sensor
TECHNOLOGY
TECHNICAL DATA
SF6 channel (manufacturer technical table, 组合1 p.2766): NDIR; range 0–3000 ppm; accuracy ±2% FS at 25°C; resolution 1 ppm; repeatability ≤±1% FS; T90 <30 s (diffusion); preheat <15 s.
Oxygen channel (manufacturer communication register table, 组合1 p.2768): Oxygen concentration is exposed as a read-only register: function code 04; register 4X0013/019; PLC address 0020; data type signed 16-bit integer (int16), actual value. This confirms an O2 concentration output/register only. The manual does not state the O2 measurement range, accuracy, resolution, sensor principle, or response time; those fields remain HOLD.
Common interface and operating conditions: RS485; Modbus RTU with CRC16; default 9600 baud, 8 data bits, no parity, 1 stop bit; DC10–30V; average current ≤200mA; operating temperature -20 to 60°C; operating humidity 0–95% RH non-condensing; storage -30 to 70°C; pressure 80–120 kPa; IP54.
Identity note: The overview on p.2765 contains an SF601 model-name typo. The cover on p.2762 identifies HANS-SFO01. Do not merge SFO01 with SF601.
SPECIFICATIONS
SFO01
SF6 channel (manufacturer technical table, 组合1 p.2766): NDIR; range 0–3000 ppm; accuracy ±2% FS at 25°C; resolution 1 ppm; repeatability ≤±1% FS; T90 <30 s (diffusion); preheat <15 s.
Oxygen channel (manufacturer communication register table, 组合1 p.2768): Oxygen concentration is exposed as a read-only register: function code 04; register 4X0013/019; PLC address 0020; data type signed 16-bit integer (int16), actual value. This confirms an O2 concentration output/register only. The manual does not state the O2 measurement range, accuracy, resolution, sensor principle, or response time; those fields remain HOLD.
Common interface and operating conditions: RS485; Modbus RTU with CRC16; default 9600 baud, 8 data bits, no parity, 1 stop bit; DC10–30V; average current ≤200mA; operating temperature -20 to 60°C; operating humidity 0–95% RH non-condensing; storage -30 to 70°C; pressure 80–120 kPa; IP54.
Identity note: The overview on p.2765 contains an SF601 model-name typo. The cover on p.2762 identifies HANS-SFO01. Do not merge SFO01 with SF601.