NS01-R4
HANS-NS01-R4 is an industrial sound-level sensor for continuous noise monitoring in locations such as plant rooms, basements, libraries, classrooms, warehouses and production areas. Its dedicated V1.3 manual specifies an electret microphone element and an RS-485 interface using Modbus RTU. The sensor measures 30–130 dB with 1 dB standard resolution (0.1 dB optional) and an A-weighting response over 31.5 Hz–8 kHz. It operates from an external DC 12–24 V supply, has an IP65 enclosure and is designed for wall mounting. The default serial settings are 9600 bit/s, 8 data bits, no parity and 1 stop bit (8N1); configurable rates are 1200, 2400, 4800, 9600, 57600 and 115200 bit/s. The factory device address is 1 and the configurable address range is 1–252. The manual uses function code 0x03 for measurement-register reads and 0x06 for address/baud-rate writes, with CRC checking. Allow at least 200 ms for polling/response timing as advised in the manual.


PRODUCT TYPE
Industrial Sensor
TECHNOLOGY
TECHNICAL DATA
Model: HANS-NS01-R4.
Measurement: 30–130 dB; 1 dB standard resolution, 0.1 dB optional; 31.5 Hz–8 kHz; A-weighting.
Communication: RS485 Modbus RTU; 9600 bit/s default; 8N1; configurable address 1–252.
Power: DC 12–24 V.
Protection: IP65; wall-mounted; operating temperature −25 to +60°C.
SPECIFICATIONS
HANS-NS01-R4 Industrial Sound-Level Sensor
Sensor: Electret microphone with dedicated noise-processing circuitry.
Measurement: 30–130 dB; 1 dB standard resolution, 0.1 dB optional; 31.5 Hz–8 kHz frequency range; A-weighting.
Communication: RS485 Modbus RTU. Function code 0x03 reads measurement registers; 0x06 writes device address and baud-rate registers. CRC checking is required.
Serial settings: 8 data bits, no parity, 1 stop bit (8N1). Configurable baud rates: 1200, 2400, 4800, 9600, 57600 and 115200 bit/s; default 9600 bit/s. Device address 1–252; default 1.
Power and protection: DC 12–24 V external supply; IP65; operating temperature −25 to +60°C; storage temperature −40 to +80°C; humidity 0–95% RH.
Installation: Wall-mounted. Check supply polarity, unique device addresses, serial settings and RS485 A/B wiring. Allow at least 200 ms for polling and response timing; use suitable bus reinforcement and 120 Ω termination for long or heavily loaded RS485 networks.
KEY FEATURES
- Noise measurement range: 30–130 dB
- 1 dB standard resolution; 0.1 dB optional
- A-weighting; 31.5 Hz–8 kHz
- RS485 Modbus RTU; CRC checking
- DC 12–24 V external supply
- IP65 enclosure; wall-mounted
- Configurable serial baud rate and device address