HANS-L520 LoRa Wireless Intelligent Gateway
HANS-L520 is a LoRa wireless intelligent gateway for self-organizing sensor networks. The manufacturer V1.3 manuals identify the same L520 model on both covers and the technical parameter table. It supports standard Modbus, RS485 and RS232 host interfaces, DC 10–24 V / 1 A, +20 dBm transmit power, -148 dBm receive sensitivity, 200–15000 bps air rate, up to 16 sensor acquisition nodes, 3 km line-of-sight transmission, configurable Modbus address 129–254 (default 254), and 90 × 86 × 42 mm dimensions. The temperature/humidity and noise-titled V1.3 manuals share the same model and core technical table; the noise-titled document's body repeats the temperature/humidity network instructions and does not establish a second gateway model. Inner-page headers repeatedly say HANS-L502, while both covers and the technical table identify HANS-L520. Retain this header discrepancy as a source variance; do not create or merge an L502 product. model configurations, compatibility or availability have not been independently verified. Please contact HANS for technical confirmation and a quotation before purchasing.


PRODUCT TYPE
Wireless Acquisition / Gateway
TECHNOLOGY
TECHNICAL DATA
Model: HANS-L520, V1.3.
Gateway role: LoRa wireless self-organizing network gateway; standard Modbus protocol; stores downstream sensor values in gateway registers for the RS485 host to read.
Capacity: Up to 16 sensor acquisition slave devices.
Interfaces: RS485 + RS232 + LoRa; Modbus RTU.
Power: DC 10–24 V / 1 A.
Radio: +20 dBm transmit power; -148 dBm receive sensitivity; air rate 200–15000 bps; line-of-sight distance 3 km.
Configuration: Modbus address range 129–254; default 254.
Environment and size: -40 to +85°C; 10–90% RH; 90 × 86 × 42 mm.
SPECIFICATIONS
L520
Model: HANS-L520, V1.3. Two technical documentations (temperature/humidity-titled and noise-titled) share the same model and technical table; one gateway parent only.
Role: LoRa wireless self-organizing network gateway. Supports standard Modbus and stores downstream sensor data in gateway registers for the RS485 host to read.
Capacity: Up to 16 sensor acquisition slave devices.
Interfaces/protocol: RS485 + RS232 + LoRa; Modbus RTU.
Power: DC 10–24 V / 1 A. Transmit power +20 dBm; receive sensitivity -148 dBm; air rate 200–15000 bps; line-of-sight distance 3 km.
Configuration: Modbus address 129–254, default 254.
Environment/size: -40 to +85°C; 10–90% RH; 90 × 86 × 42 mm.
KEY FEATURES
HANS-L520 is a LoRa wireless intelligent gateway for self-organizing sensor networks. The manufacturer V1.3 manuals identify the same L520 model on both covers and the technical parameter table. It supports standard Modbus, RS485 and RS232 host interfaces, DC 10–24 V / 1 A, +20 dBm transmit power, -148 dBm receive sensitivity, 200–15000 bps air rate, up to 16 sensor acquisition nodes, 3 km line-of-sight transmission, configurable Modbus address 129–254 (default 254), and 90 × 86 × 42 mm dimensions.
PRODUCT SYSTEM