FS01
FS01 is listed in the HANS Industrial IoT product catalog as a weather sensor under Industrial Sensors. Measurement range: 0–30 m/s, 0–50 m/s or 0–60 m/s; other ranges custom. Accuracy: ±(0.3 + 0.03V) m/s. Power supply: 5–24 VDC for 0–2V or RS485; 12–24 VDC for 0–5V, 0–10V or 4–20mA. Communication: RS-485 Modbus RTU for RS485 output variant. Operating temperature: −30 to +70°C. Reference information only; model configuration and availability are subject to confirmation before ordering.


PRODUCT TYPE
Weather Sensor
TECHNOLOGY
TECHNICAL DATA
Model: HANS-FS01 V1.1 cup-type wind-speed sensor (manual cover prints V1.0 beneath the model; version record p.2396 records V1.1 and notes contact-details update).
Measurement: Wind-speed ranges 0–30m/s, 0–50m/s or 0–60m/s; other ranges customizable. Starting wind speed ≤0.3m/s. Accuracy ±(0.3 + 0.03V)m/s. Stabilization time <1s; response time <1s. Reports wind speed and Beaufort wind-force level.
Supply/output configurations: DC 5–24V for 0–2V or RS485 outputs; DC 12–24V for 0–5V, 0–10V or 4–20mA. Output options: one of 0–2V/0–5V/0–10V, 4–20mA current loop, or RS485 Modbus RTU. Analog version uses 3-wire cable; RS485 uses 4-wire cable; 2m standard cable, length selectable. Do not assume multiple output types are simultaneously installed.
Environment/construction: Operating temperature -30 to +70°C; working humidity ≤100% RH; storage temperature -30 to +70°C; storage humidity ≤100% RH. Cup anemometer housing is aluminum, weather-resistant, high-strength, corrosion-resistant and waterproof.
Communications: RS485 Modbus RTU; address 1–252, default 1; baud 1200/2400/4800/9600/57600/115200, default 9600; 8 data bits, no parity, 1 stop bit, CRC. Register 0x0000 returns wind speed and wind-force level; register address can be changed using function 0x06. Wind-speed register value is divided by 10 to obtain m/s; wind-force value is an integer.
Analog conversion: For 0–30m/s: 0–2V, speed=15×V; 0–5V, speed=6×V; 0–10V, speed=3×V; 4–20mA, speed=1.875×A−7.5. For 0–60m/s: 0–2V, speed=30×V; 0–5V, speed=12×V; 0–10V, speed=6×V; 4–20mA, speed=3.75×A−15. Pulse conversion listed as 0.083m/s per pulse.
Installation/use: The sensor is a precision instrument; do not disassemble or alter factory wiring/components. Avoid moisture and sticky particles entering the sensor. For RS485, observe A/B polarity, baud, address and polling timing; the manual recommends poll/wait intervals above 200ms.
Configuration boundary: Select one range and one output/supply combination for the ordered unit. Other ranges and cable lengths are customizable.
SPECIFICATIONS
FS01
Model: HANS-FS01 V1.1 cup-type wind-speed sensor (manual cover prints V1.0 beneath the model; version record p.2396 records V1.1 and notes contact-details update).
Measurement: Wind-speed ranges 0–30m/s, 0–50m/s or 0–60m/s; other ranges customizable. Starting wind speed ≤0.3m/s. Accuracy ±(0.3 + 0.03V)m/s. Stabilization time <1s; response time <1s. Reports wind speed and Beaufort wind-force level.
Supply/output configurations: DC 5–24V for 0–2V or RS485 outputs; DC 12–24V for 0–5V, 0–10V or 4–20mA. Output options: one of 0–2V/0–5V/0–10V, 4–20mA current loop, or RS485 Modbus RTU. Analog version uses 3-wire cable; RS485 uses 4-wire cable; 2m standard cable, length selectable. Do not assume multiple output types are simultaneously installed.
Environment/construction: Operating temperature -30 to +70°C; working humidity ≤100% RH; storage temperature -30 to +70°C; storage humidity ≤100% RH. Cup anemometer housing is aluminum, weather-resistant, high-strength, corrosion-resistant and waterproof.
Communications: RS485 Modbus RTU; address 1–252, default 1; baud 1200/2400/4800/9600/57600/115200, default 9600; 8 data bits, no parity, 1 stop bit, CRC. Register 0x0000 returns wind speed and wind-force level; register address can be changed using function 0x06. Wind-speed register value is divided by 10 to obtain m/s; wind-force value is an integer.
Analog conversion: For 0–30m/s: 0–2V, speed=15×V; 0–5V, speed=6×V; 0–10V, speed=3×V; 4–20mA, speed=1.875×A−7.5. For 0–60m/s: 0–2V, speed=30×V; 0–5V, speed=12×V; 0–10V, speed=6×V; 4–20mA, speed=3.75×A−15. Pulse conversion listed as 0.083m/s per pulse.
Installation/use: The sensor is a precision instrument; do not disassemble or alter factory wiring/components. Avoid moisture and sticky particles entering the sensor. For RS485, observe A/B polarity, baud, address and polling timing; the manual recommends poll/wait intervals above 200ms.
Configuration boundary: Select one range and one output/supply combination for the ordered unit. Other ranges and cable lengths are customizable.
KEY FEATURES
FS01 is listed in the HANS Industrial IoT product catalog as a weather sensor under Industrial Sensors. Measurement range: 0–30 m/s, 0–50 m/s or 0–60 m/s; other ranges custom. Accuracy: ±(0.3 + 0.03V) m/s.
PRODUCT SYSTEM