FG01 Household Combustible Gas Detector
FG01 is a household combustible-gas detector designed specifically for natural gas (methane) leakage. It provides audible and visual alarms and can control a solenoid valve or exhaust fan when the alarm threshold is reached.


PRODUCT TYPE
Combustible Gas Detector
TECHNOLOGY
TECHNICAL DATA
Model: HANS-FG01 V1.0 household combustible gas detector for methane/natural gas only. The manual explicitly states it is not suitable for detecting other gases.
Detection/alarm: Semiconductor gas sensor; alarm threshold 8%LEL; response <30s; audible alarm 70–115dB with visual alarm; historical event storage: 200 alarm records, 200 alarm-recovery records, 100 fault records, 100 fault-recovery records, 50 power-off and 50 power-on records.
Electrical: AC220V/50Hz; power ≤3W. Alarm outputs are alternatives: one DC12V active pulse output for solenoid valve, and one optional passive dry-contact output for fan control. The device section says choose one of the two output modes; do not claim both are present on every unit.
Environment/life: Indoor household use; 0 to +55°C; 10–95% RH non-condensing; service life ≥5 years in clean air; wall mount; 125 × 75 × 36mm.
Operation: Initial warm-up approximately 180s; alarm recovery when combustible gas concentration falls below the set threshold; self-test by short press; long press silences; sensor fault and end-of-life indications. Network state can be uploaded wirelessly; manual shows connectivity but no specific wireless protocol or model-specific communication register map.
Installation: For methane, mount on ceiling or within 0.3m below ceiling, preferably within 1.5m of gas source, in same room and same separated area as gas appliance. Avoid direct heat from stove, oil fumes, bathrooms/high humidity, aerosols, paint, adhesives and other irritating vapors.
Safety boundary: Natural gas/methane only. Do not infer LPG, propane, CO or other gas detection. Valve pulse and fan relay are selectable output configurations.
SPECIFICATIONS
FG01
Model: HANS-FG01 V1.0 household combustible gas detector for methane/natural gas only. The manual explicitly states it is not suitable for detecting other gases.
Detection/alarm: Semiconductor gas sensor; alarm threshold 8%LEL; response <30s; audible alarm 70–115dB with visual alarm; historical event storage: 200 alarm records, 200 alarm-recovery records, 100 fault records, 100 fault-recovery records, 50 power-off and 50 power-on records.
Electrical: AC220V/50Hz; power ≤3W. Alarm outputs are alternatives: one DC12V active pulse output for solenoid valve, and one optional passive dry-contact output for fan control. The device section says choose one of the two output modes; do not claim both are present on every unit.
Environment/life: Indoor household use; 0 to +55°C; 10–95% RH non-condensing; service life ≥5 years in clean air; wall mount; 125 × 75 × 36mm.
Operation: Initial warm-up approximately 180s; alarm recovery when combustible gas concentration falls below the set threshold; self-test by short press; long press silences; sensor fault and end-of-life indications. Network state can be uploaded wirelessly; manual shows connectivity but no specific wireless protocol or model-specific communication register map.
Installation: For methane, mount on ceiling or within 0.3m below ceiling, preferably within 1.5m of gas source, in same room and same separated area as gas appliance. Avoid direct heat from stove, oil fumes, bathrooms/high humidity, aerosols, paint, adhesives and other irritating vapors.
Safety boundary: Natural gas/methane only. Do not infer LPG, propane, CO or other gas detection. Valve pulse and fan relay are selectable output configurations.
KEY FEATURES
FG01 is a household combustible-gas detector designed specifically for natural gas (methane) leakage. It provides audible and visual alarms and can control a solenoid valve or exhaust fan when the alarm threshold is reached.
PRODUCT SYSTEM